  1. Replies
    2
    Views
    789

    on the join profile "Default Subordinate Use Fox...

    on the join profile "Default Subordinate Use Fox TLS:" is it set to true if your using TLS
  2. Are these Spyder controllers? It might be com...

    Are these Spyder controllers? It might be com issues or you have a bad temperature sensor
  3. You need a software(service tool 5) or get a...

    You need a software(service tool 5) or get a carrier rep to map the CCN points to the (33CNTRAN485)translator.
  4. You might need the old LCBS software to program...

    You might need the old LCBS software to program these xl15
  5. downgrade the software to 4.8 and see if that...

    downgrade the software to 4.8 and see if that would work.
  6. I use it on Network input, such as occupancy or...

    I use it on Network input, such as occupancy or mode(cooling heating auto). I don't use rewrite policy on all the network input, just the important ones. Don't use it on network setpoints, that...
  7. Replies
    7
    Views
    1,502

    Check the Spyder firmware and make sure it's up...

    Check the Spyder firmware and make sure it's up to date.
  8. Replies
    10
    Views
    1,367

    What is your occupied cooling and heating setpoint

    What is your occupied cooling and heating setpoint
  9. Replies
    10
    Views
    1,367

    Go to your palette, open HoneywellVenomLon. Drag...

    Go to your palette, open HoneywellVenomLon. Drag in NciRefreshExt to your device. See if that solve the issue
  10. Replies
    10
    Views
    1,367

    Honeywell calls the offset, zero energy band. If...

    Honeywell calls the offset, zero energy band. If you set the occupied cooling setpoint 72 and occupied heating setpoint of 68. Then you have +2 and -2 offset. When you set your set point to 74, your...
  11. Replies
    10
    Views
    1,367

    Are you using Stryker or Venmo app on a spyder ?

    Are you using Stryker or Venmo app on a spyder ?
  12. Replies
    35
    Views
    15,331

    Thank you

    Thank you
  13. Replies
    13
    Views
    3,216

    Thanks a lot Reckles

    Thanks a lot Reckles
  14. Replies
    13
    Views
    3,216

    Alerton ACM global controller platform

    I have an Alerton ACM global controller. It is running Niagara ax version 3.8.41. I am able to login to the station. I donít have the password to the platform. Is there a way to serial shell mode the...
  15. I had that issue with input getting a value and...

    I had that issue with input getting a value and output either not updating or reverting back to old value. It usually happens when your trying to integrate with a 3rd party controller. Thereís two...
  16. Thereís a point call occupancy command. 1=local...

    Thereís a point call occupancy command. 1=local 2= occupied 3 = unoccupied. The local is set to look at PIR sensor. When I set the occupancy command point to local=1. It will revert back as 3...
  17. It can be done, you should be able to discover...

    It can be done, you should be able to discover the spyder with the converter. Bacnet spyder have dip switches. Dip switch will tell you the addressing on each device....
  18. Viconics Zigbee gw2pro with vt8650 tstat write issues

    I have a jace 8000 connected to zigbee GW2-0l0 pro wireless gateway ip over bacnet. The zigbee gateway is communicating wirelessly to vt8650 Tstat. When my supervisor station send a occupied command...
  19. Replies
    2
    Views
    953

    Thank you

    Thank you
  20. Replies
    2
    Views
    953

    Honeywell Ciper 50

    Have anyone ever used a device call cipher 50
  21. Replies
    14
    Views
    5,421

    Make sure you have the correct domain ID. You...

    Make sure you have the correct domain ID. You could find out the domain ID in utilities manager.
  22. Replies
    7
    Views
    1,169

    Thank you

    Thank you
  23. Replies
    7
    Views
    1,169

    Thank you I will give it a try.

    Thank you I will give it a try.
  24. Replies
    7
    Views
    1,169

    I put my thermometer next to the Tstat and itís...

    I put my thermometer next to the Tstat and itís reading 72. On the front end it is reading 70. How do I configure an offset on the continuum explorer.
  25. Replies
    7
    Views
    1,169

    Andover Continuum calibrating sensor

    Could anyone tell me how to calibrate space temp sensor?
  26. Replies
    0
    Views
    696

    Smardt chiller via modbus

    Iím using a Honeywell jace 8000 communicating via modbus Ethernet. I have an issue with NviChillerEnable_40001. Iím writing a 1 to input 16 but it is outputing a 3. I tried emergency override,...