  1. Manometer tubing is used for very low pressures....

    Manometer tubing is used for very low pressures. Shouldn't be an issue. If it was for higher pressures, then yes, the static pressure of proportionately higher for smaller diameters, just as it is in...
  2. Replies
    32
    Views
    1,113

    There's nothing in the codes and stds....

    There's nothing in the codes and stds. prohibiting a double female single walled vent connector in the IRC Ch 24 or NFPA 54. If you have your requisite min. 2 screws per joint, what's the problem?
  3. Replies
    32
    Views
    1,113

    No pic showing connection to B-vent. You should...

    No pic showing connection to B-vent. You should have a "draft hood connector" as your transition to single walled pipe. That allows you to connect the single walled piping without risk of penetrating...
  4. Replies
    85
    Views
    2,878

    LOL Wayne. I have the manual and read it. They...

    LOL Wayne. I have the manual and read it. They don't say it's worthless to test below 3"wg. They claim that when testing properly installed ductwork, the leakage from properly made seams and joints...
  5. Replies
    85
    Views
    2,878

    There are several reasons to use this equipment....

    There are several reasons to use this equipment. You can use it with infrared thermography to locate leaks to the exterior for calculation of energy waste and savings after remediation. You can use...
  6. Replies
    149
    Views
    3,463

    A package unit as shown has both supply and...

    A package unit as shown has both supply and return trunks adjacent to themselves but also close to the combustion chamber and exhaust. If there is a shunt in the ducts, 'stuff' from one side and...
  7. When you change from common vented appliances to...

    When you change from common vented appliances to a single gas appliance, this triggers the need for a level II inspection per NFPA 211. That will undoubtedly indicate the need for a chimney liner....
  8. Check burner compartment to blower for bypasses. ...

    Check burner compartment to blower for bypasses.
    Did you perform combustion analysis?
    Are there any low points/ sags/ traps in the venting?
    Is combustion air intake hard piped to outdoors or...
  9. Replies
    11
    Views
    1,152

    A chimney must be suitable for the class of...

    A chimney must be suitable for the class of service. A 'chimney' is not rated for positive vent pressure. If you have a CAT III or IV gas appliance, it must be vented using listed venting (UL1738)...
  10. Replies
    1
    Views
    684

    Galvanized steel pipe has been fine and accepted...

    Galvanized steel pipe has been fine and accepted by the gas utility. They require galvy outdoors so no problem with H2S. If you're really worried about it, take a piece of chrome plated brass...
  11. You need to determine if the noise is coming from...

    You need to determine if the noise is coming from the box or the liners. Typically, banging in a metal fireplace is caused by the box being wracked so sitting uneven with stresses. you may need to...
  12. Replies
    22
    Views
    1,756

    Give it 20-40 min. then re-test. ANSI Z21.88...

    Give it 20-40 min. then re-test.

    ANSI Z21.88 calls for 25ppm AF with half burner covered with embers. They do this under ideal conditions with the unit really cooked in and going for as long as...
  13. Replies
    22
    Views
    1,756

    I use SprayWay because it's an alcohol-based...

    I use SprayWay because it's an alcohol-based foam. Mfrs. have determined ammonia-based glass cleaners can cause a rainbow discoloration of the tempered and ceramic glass (yours is ceramic). To remove...
  14. Replies
    22
    Views
    1,756

    You can seal the circumferential joints once...

    You can seal the circumferential joints once you've established the layout then silicone the firestop penetrations both inner and outer. You can attach a short length of tubing to a caulking gun for...
  15. Replies
    22
    Views
    1,756

    The O2 number will change as the vent heats up...

    The O2 number will change as the vent heats up and thermosyphons. That's about normal for a gas DV with a short vent run. The CO is supposed to be <25ppm AF. That's on a unit in perfect condition...
  16. Replies
    22
    Views
    1,756

    When you frame out for the firestop that forces...

    When you frame out for the firestop that forces your clearances to combustibles- 3" top/ 1" sides and bottom. Frame it in on all four sides then insulate up to this box but not inside. The sheathing...
  17. Replies
    22
    Views
    1,756

    You should be fine with your plan Gravity. It is...

    You should be fine with your plan Gravity. It is advisable to to vent off the top then out if you have the 3" clearance but if not it should vent just fine out the rear at that horizontal offset.
    ...
  18. Replies
    23
    Views
    932

    PVC has a maximum operating temperature of 140F....

    PVC has a maximum operating temperature of 140F. Typical flue gas outlet temps. are around 110F for normal operation. You can use a tapered thread brass, Nylon, or ss plug with a dab of standard 300F...
  19. Replies
    3
    Views
    1,063

    You would need to remove the flue tiles to make...

    You would need to remove the flue tiles to make room for a liner with the requisite insulation to meet the listing for a zero clearance to combustibles. Any competent chimney contractor should be...
  20. Replies
    12
    Views
    638

    Aside from being a code violation and dangerous,...

    Aside from being a code violation and dangerous, open flame testing is virtually useless. The lower explosive limit for methane is 4.4% or about 44,000 ppm. You should be able to detect that level by...
  21. Replies
    1
    Views
    1,053

    BE 41 allows vented logs. If the BE48 has gas...

    BE 41 allows vented logs. If the BE48 has gas knockouts then yes, you can install vented logs. These units were NOT listed for use with ventfree gas logs.
  22. Replies
    4
    Views
    2,127

    Terrible news! Rudy was one of the legends in CO...

    Terrible news! Rudy was one of the legends in CO education and a great guy. He will be missed.
  23. Thread: Boom !

    by hearthman
    Replies
    31
    Views
    4,639

    You musta' studied hard, Pop. You passed. Any...

    You musta' studied hard, Pop. You passed. Any chance pics and make/ model?
  24. You can use L vent and get it down to a 3"...

    You can use L vent and get it down to a 3" clearance to combustibles. You'll need a thimble to properly pass through that combustible wall. Hopefully, you already have a listed liner installed into...
  25. Replies
    27
    Views
    1,274

    I use this all the time and it works great:...

    I use this all the time and it works great: https://www.amazon.com/HENSLER-SHEET-METAL-HAND-BENDER/dp/B01DDWPE84
  26. Replies
    10
    Views
    439

    Messing with the forced air vents can upset the...

    Messing with the forced air vents can upset the balance in the home. If you have any other naturally vented combustion appliances, such as a gas water heater and you cause a depressurization, you can...
  27. Replies
    16
    Views
    838

    See if you have clearance for oval B-vent. It...

    See if you have clearance for oval B-vent. It used to be all ovalized B-vent was deemed BW vent for wall furnaces only. Just pay close attention to the clearances and firestopping requirements....
  28. Replies
    1
    Views
    2,167

    We can't give DIY advice here. See Site Rules....

    We can't give DIY advice here. See Site Rules. You are testing incorrectly. None of what you posted makes sense. If you are a tech, get your post count up so you can post in the Pro forums where we...
  29. Suggestion for Malco make reversible mag driver 7/16" x 1/2"

    https://www.malcoproducts.com/ideas/

    I pinged them with this idea based off their successful reversible magnetic hex bit drivers. I think a lot of sparkies and wrench heads could use such a bit...
  30. Thread: SPK problems

    by hearthman
    Replies
    1
    Views
    1,843

    First of all, replacing a thermocouple IS doing...

    First of all, replacing a thermocouple IS doing DIY.

    The Safety Pilot Kit or SPK is an RH Peterson part. Is this the logset you have? If so, a professional can change the SPK out BUT...…….. ...
  31. Why stainless steel? Because it lasts, unlike...

    Why stainless steel? Because it lasts, unlike beer can liners. I pull them all the time. 100% of the aluminum liners I inspect are corroded. When you common vent an 80% furnace in one, you'll surely...
  32. Replies
    18
    Views
    2,607

    As long as your utility is scrubbing your gas,...

    As long as your utility is scrubbing your gas, you don't need a 'drip' at the point of entry into the building. That means there is very little chance of liquid condensate draining into an appliance...
  33. Replies
    3
    Views
    2,982

    Hard to find the manual. I hate mfrs. who hide...

    Hard to find the manual. I hate mfrs. who hide their installation manuals but provide tons of fluff. From what I've found, this unit carries a zero clearance to a combustible floor. Talk to your...
  34. Replies
    3
    Views
    2,982

    If the fireplace has a convective chamber under...

    If the fireplace has a convective chamber under the firebox you're probably fine. These fireplaces are listed for installation on a combustible floor with less than 90F temp rise under the firebox...
  35. Replies
    4
    Views
    2,445

    The gas valve is rated 225F. Burning in a mason's...

    The gas valve is rated 225F. Burning in a mason's jar will probably overheat it.

    Combustion needs oxygen. Burning in a mason's jar will probably use up the oxygen faster than it can entrain...
  36. Cut your wood smaller but burn it hot. Get a...

    Cut your wood smaller but burn it hot.
    Get a smaller stove
  37. Replies
    6
    Views
    3,340

    I flagged your other post with poor advice. You...

    I flagged your other post with poor advice. You really shouldn't be giving advice if you don't know what you're talking about.

    For one, the glass on these fireplaces is tested and listed with...
  38. Replies
    3
    Views
    598

    If you cut a hole in the ceiling, it will draft...

    If you cut a hole in the ceiling, it will draft CAZ air up into the attic further depressurizing the CAZ. If you deliberately depressurize the CAZ to force attic air down the MUA tube into the CAZ,...
  39. Replies
    30
    Views
    2,424

    813332 Screw this to a drive. The rounded edge...

    813332

    Screw this to a drive. The rounded edge of the clip can act as a squeegee.
  40. Replies
    16
    Views
    1,572

    https://www.levelok.com/product-category/ladder-st...

    https://www.levelok.com/product-category/ladder-standouts-ladder-standoffs/

    We require these on all extension ladders or where there is a gutter. Quick to mount and very stabile and light. Replace...
  41. Replies
    6
    Views
    545

    The venting must meet the code. That means a lot...

    The venting must meet the code. That means a lot of things here. The foil tape is not allowed nor needed on the B-vent. The elbow appears to be modified. There should be a draft hood connector that...
  42. Need to run combustion analysis. Also consider a...

    Need to run combustion analysis. Also consider a post purge cycle of about 4 minutes if not already.
  43. If you have turned your control knob to 'on',...

    If you have turned your control knob to 'on', have maintained the fireplace and the gas is not partially obstructed such as a partially closed valve then you need to call a pro. Sorry but we can't...
  44. Replies
    2
    Views
    2,036

    The igniter is part of that Honeywell valve,...

    The igniter is part of that Honeywell valve, which is no longer made. Check the instruction manual for your fireplace to see if they give info. on troubleshooting the igniter. If you are not getting...
  45. Replies
    8
    Views
    614

    Ventfree are tested in a lab to emit no more than...

    Ventfree are tested in a lab to emit no more than 200ppm CO. That's not in a home with foot traffic, kids playing, and other forms of air movement that can cool the flames and cause flame...
  46. Replies
    5
    Views
    736

    What vent pipe are you using?

    What vent pipe are you using?
  47. Replies
    8
    Views
    568

    Can't. Gotta be rated 250 F by code.

    Can't. Gotta be rated 250 F by code.
  48. Replies
    4
    Views
    2,063

    #26 shows the fan motor--not a transformer.

    #26 shows the fan motor--not a transformer.
  49. Replies
    7
    Views
    2,402

    Don't hold your breath on that 30%. Outside air...

    Don't hold your breath on that 30%. Outside air is cold. It slows combustion. These kits were a seemingly good idea on paper but not in practice. The open hearth will draw its combustion air from the...
  50. Replies
    7
    Views
    2,402

    An outside air kit isn't going to warm you. If it...

    An outside air kit isn't going to warm you. If it is located in a negative pressure zone, it can suck heated air out of the fireplace into the flex duct.
    Are your doors labelled "Heatilator"? If...