Search:

Type: Posts; User: GenesisRefrig

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Good luck on your surgery. That sucks man.

    Good luck on your surgery. That sucks man.
  2. Replies
    3
    Views
    134

    Where do I find that?

    Where do I find that?
  3. Replies
    3
    Views
    134

    Refrigeration Engineer Needed!

    Ok guys, Iíve been working with a global manufacturer in Northern MINNESOTA who is developing a refrigeration system for heavy industry. They have a great engineering team and Iíve been consulting...
  4. Replies
    16
    Views
    628

    I used to be an Ice-O-Matic fan, but not anymore...

    I used to be an Ice-O-Matic fan, but not anymore since they went all electronic. Kool-Aire by Manitowoc has been good. They are Manitowoc machines without all the bells and whistles.
  5. In our region, Northern MN, we lock out heat...

    In our region, Northern MN, we lock out heat pumps at 25-30 degrees. Then the furnace takes over.
  6. Replies
    5
    Views
    258

    Not sure about Carrier brand, but Mitsubishi...

    Not sure about Carrier brand, but Mitsubishi mini-splits will bleed through a small amount of refrigerant in heads that are not calling for heat when another head is calling for heat. It sound like...
  7. Is it possible that running at such a high...

    Is it possible that running at such a high pressure (rich) plugged up the heat exchangers?
  8. Replies
    183
    Views
    3,043

    If it were me, Iíd start taking panels off until...

    If it were me, Iíd start taking panels off until I could visualize the limit. Then Iíd take the screw(s) off the limit and replace it. Then Iíd figure out why the limit was tripping and fix that...
  9. Is this a new install? If so, I’d be on the horn...

    Is this a new install? If so, I’d be on the horn with my distributor and have a new unit shipped. Leaking out of the box, Mitsubishi can find their own leak.
  10. Replies
    32
    Views
    1,112

    I agree. Look at the last picture. The horizontal...

    I agree. Look at the last picture. The horizontal run has a piece of pipe with no crimp. It slides on the outside of both adjoining pipes.
    In our area, we can run single wall pipe inside, but must...
  11. Replies
    12
    Views
    624

    I use a 100’ hose that fits in a 1-Ĺ gallon...

    I use a 100’ hose that fits in a 1-Ĺ gallon bucket. It’s one of those expanding hoses that shrivels up when there is no pressure. Think it came from Walmart. I usually need to buy a new one every...
  12. Replies
    8
    Views
    335

    Why start this thread 10 minutes after starting...

    Why start this thread 10 minutes after starting your last one on the same exact topic?
  13. Replies
    8
    Views
    389

    “Piston kit charge”???

    “Piston kit charge”???
  14. Replies
    13
    Views
    948

    Very nice and clean. You should be proud! Those...

    Very nice and clean. You should be proud! Those KE2 Evap Efficiency controllers are awesome.
  15. Replies
    10
    Views
    522

    ď We need to get you a better flashlight ....Ē ...

    ď We need to get you a better flashlight ....Ē

    Hah! :cheers:
  16. Replies
    10
    Views
    522

    By the way, it ran perfectly when I finally...

    By the way, it ran perfectly when I finally finished.
  17. Replies
    10
    Views
    522

    The dirt was hiding

    Got called on a 6’ Federal open deli case not cooling. A little history... About 2 months ago, this unit got a new compressor and condenser fan motor. At that time, I also blew out the condenser coil...
  18. Replies
    17
    Views
    620

    If you had this installed 6 months ago, why...

    If you had this installed 6 months ago, why aren’t you calling the installing contractor for a warranty repair? We give a 1 year warranty on all of our installs.
  19. Replies
    9
    Views
    1,388

    KE2Therm is top-notch. I accidentally smoked a...

    KE2Therm is top-notch. I accidentally smoked a controller by my own stupid mistake. Of course it was on a weekend and late at night. Thought I’d give a “Hail Mary” call to KE2Therm, and guess...
  20. Replies
    41
    Views
    1,745

    Nice work on the HVAC and really nice work on the...

    Nice work on the HVAC and really nice work on the electrical. I like both high and low outlets.

    Two things Iíve never heard:
    ďI wish this garage wasnít so bigĒ.
    ďI wish I didnít have so many...
  21. Replies
    8
    Views
    429

    I burn Nests. Hornets nests, wasp nests, bee...

    I burn Nests. Hornets nests, wasp nests, bee nests, Google Nests.
  22. We charge time and a half for rooftop calls when...

    We charge time and a half for rooftop calls when itís below zero F.
  23. Replies
    6
    Views
    580

    I just installed Ring floodlight cams. They are...

    I just installed Ring floodlight cams. They are great. You can adjust the motion detection zones, and even set them to detect humans only. One plus is they also record video.
  24. Welcome. As you probably know, there is a TON of...

    Welcome. As you probably know, there is a TON of knowledge here. One of the best tools in my bag is hvac-talk
  25. Replies
    4
    Views
    322

    Helping Restaurants and Bars

    We have had a truly record breaking year and I feel totally blessed. Last week I decided that if I was working for a restaurant or bar that is shuttered due to the ignorance of our idiot governor, I...
  26. Same here. I usually have to look at them to see...

    Same here. I usually have to look at them to see if they are running. They are so quiet that I need to see the fan turning.
  27. Canít help with the message you got on your...

    Canít help with the message you got on your phone, but I can help with the bedroom overheating.

    First, your tech needs to make sure your branch box is not cross wired/piped.
    If all the piping and...
  28. Replies
    13
    Views
    1,270

    MINNESOTA/Canadian border here. Discovered a game...

    MINNESOTA/Canadian border here. Discovered a game changer about 3 years ago for cold rooftops. I was working on a walk in freezer unit on the roof of a casino with their maintenance guy. He asked me...
  29. I cut off EVERY factory flare. Experience. Don’t...

    I cut off EVERY factory flare. Experience. Don’t trust them as far as I can spit.
  30. My question to all of you -- what is the downside...

    My question to all of you -- what is the downside of keeping the outdoor temperature sensor indoors while running the system in auto mode via the Econet tstat? I am trying to anticipate the...
  31. Replies
    147
    Views
    4,227

    I’ll try not to make this too long. According to...

    I’ll try not to make this too long. According to my mother, when I was a toddler, she came into my room to find my crib/bed disassembled and I had the fasteners layer out on the floor from longest to...
  32. The only problem I see with mounting them that...

    The only problem I see with mounting them that close is difficulty in annual coil cleaning.
  33. I agree. Maybe try an experiment. When it’s below...

    I agree. Maybe try an experiment. When it’s below 40, turn on every head and set the temps at least 5 degrees above room temp. Listen and see if you still have the noise.

    Right now, where I am,...
  34. Replies
    13
    Views
    583

    The RV units are no more than 80lbs. They are...

    The RV units are no more than 80lbs. They are made to take the bumps and potholes. Cut a 12” hole in the roof, bolt it down, plug it into your inverter, done.
  35. Replies
    14
    Views
    637

    So the gas valve is not accessible from the top?...

    So the gas valve is not accessible from the top?

    I’ve got an Empire floor furnace (millivolt) running in my cabin 10’ from me right now. It has a 2’-3’ rod that goes down to the gas valve below....
  36. Replies
    13
    Views
    583

    What about a roof mount RV unit?

    What about a roof mount RV unit?
  37. I do mostly commercial and industrial...

    I do mostly commercial and industrial refrigeration and about 80% of my work involves electrical or dirt. I would highly recommend getting as much training as possible in the electrical trade and in...
  38. Replies
    44
    Views
    2,573

    My JB 7CFM pump still pulls down to 50 microns at...

    My JB 7CFM pump still pulls down to 50 microns at 18 years old. I do almost all commercial and industrial refrigeration. If it ever craps out, I’m getting another one.
  39. Replies
    4
    Views
    613

    My van always has two cans of brake cleaner from...

    My van always has two cans of brake cleaner from the auto parts store. Best degreaser ever.
  40. It’s almost always less expensive and less labor...

    It’s almost always less expensive and less labor to install the evaporator at the same time as the furnace. Then, in the Spring, all that needs to be done is set the outdoor unit and run the lines.
  41. I have something good to say about Nest... ...

    I have something good to say about Nest...

    They have a good marketing campaign.
  42. Replies
    7
    Views
    614

    Those amps seem really high, but otherwise...

    Those amps seem really high, but otherwise everything seems pretty normal for a mechanically seized compressor. Perhaps your meter is on the wrong scale, or leads are plugged into the wrong holes?
  43. First, in your picture, that is not a...

    First, in your picture, that is not a thermocouple wire. The thermocouple is coming off the right side of that valve.

    Second, you have a dangerous situation that needs to be repaired ASAP. If...
  44. Replies
    3
    Views
    644

    Copeland D.O.A. from the factory

    31 years in the trade and never recall receiving a bad compressor from Copeland or Tecumseh. I was doing a repair on a swimming pool dehumidifier and part of the repair was replacing a CR47KQ-PFV,...
  45. Replies
    6
    Views
    763

    Wonderful. I got a new drive module today, and...

    Wonderful. I got a new drive module today, and instead of being on steroids, this one doesn’t spin at all. �� Ordered another one from United Refrigeration via next day air! What a stupid run of bad...
  46. Replies
    82
    Views
    1,526

    My point is, before you go looking at ordering...

    My point is, before you go looking at ordering parts, make sure that you need that part. You need to diagnose the problem before you replace parts.
  47. Replies
    82
    Views
    1,526

    You donít need every wire! You donít even know if...

    You donít need every wire! You donít even know if you need the flame sensor wire. Itís time to stop throwing parts at this furnace and actually diagnose the problem. If the problem turns out to be...
  48. Replies
    5
    Views
    318

    I’ve installed hundreds of Mitsubishi systems,...

    I’ve installed hundreds of Mitsubishi systems, FH, GL, etc., and have never had a noise problem. On the contrary, they are so quiet that the only way to know if they are running is to look at the fan...
  49. Replies
    82
    Views
    1,526

    I agree about unplugging the flame sensor. If the...

    I agree about unplugging the flame sensor. If the problem goes away, you’ve got a bad wire or a bad sensor
  50. Replies
    6
    Views
    763

    That, I don’t know. The part numbers of the drive...

    That, I don’t know. The part numbers of the drive modules are exactly the same.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4