  1. Replies
    4
    Views
    64

    Where did you get this unit? Who installed it?

    Where did you get this unit?
    Who installed it?
  2. Replies
    4
    Views
    64

    How does that happen, you need a Allen key?

    How does that happen, you need a Allen key?
  3. Replies
    31
    Views
    637

    Only Pro Members can PM!

    Only Pro Members can PM!
  4. How long have you had the water heater? On...

    How long have you had the water heater?

    On demand water heaters use a large amount of gas. With the other appliances running the regulator may not be able to handle the required flow.

    You need...
  5. DUMP THE WARRANTY COMPANY!

    DUMP THE WARRANTY COMPANY!
  6. Combustion #'s ?

    Combustion #'s ?
  7. Replies
    14
    Views
    206

    Close the valve, try and get 30F at the pump. ...

    Close the valve, try and get 30F at the pump.

    Compressor SH trumps evaporator.

    Measure the discharge temperature before and after adjusting the valve. 200 -225 is the limit!
  8. Thread: Multiple Gauges

    by pecmsg
    Replies
    1
    Views
    79

    Same analog gauges for over 25 years

    Same analog gauges for over 25 years
  9. Replies
    14
    Views
    206

    Clear the Sight Glass Test and adjust the SH...

    Clear the Sight Glass

    Test and adjust the SH 6" from the compressor between 20 & 40F
  10. Concentrate more on the name of the contractor...

    Concentrate more on the name of the contractor then the name on the boxs.

    The installing contractor makes or breaks a system!
  11. Hold on the Jurys still out on that one!

    Hold on the Jurys still out on that one!
  12. He has to capture the refrigerant the question is...

    He has to capture the refrigerant the question is why did the compressor fail and how much refrigerant is in there. There are alternative refrigerants that can be used as well. The next thing is at...
  13. Im hoping were talking Static Pressure!

    Im hoping were talking Static Pressure!
  14. Thread: NEW BRAND!!!

    by pecmsg
    Replies
    17
    Views
    529

    So they all get the same size.

    So they all get the same size.
  15. Thats unfortunate because they could be the...

    Thats unfortunate because they could be the reason for the failure.

    This is how it works.
    Equipment is sized for the heat load / loss of the building
    Then the ducts are sized to the...
  16. Replies
    6
    Views
    270

    From here I cant see the equipment but from what...

    From here I cant see the equipment but from what you described yes get a second opinion.
  17. Replies
    3
    Views
    211

    Find the contractor that pumped the old oil in...

    Find the contractor that pumped the old oil in there pump it out and dispose of it. Make them clean the tank as well
  18. Replies
    38
    Views
    1,984

    :gah:

    :gah:
  19. Replies
    38
    Views
    1,984

    I have the Milwaukee press tool Love It. Jaws to...

    I have the Milwaukee press tool Love It. Jaws to 3"

    Had a contractor do this job, they swear by the ridged. Several features I liked. Next tool will be ridged!
  20. That's telling me the ducts are too small and...

    That's telling me the ducts are too small and this contractor is doing his job. Did they recommend what could be done to correct the issues or give any solutions?
  21. Thread: Walk in Freezer

    by pecmsg
    Replies
    14
    Views
    372

    Not in refrigeration! 30F SH at the pump with a...

    Not in refrigeration! 30F SH at the pump with a -20 evaporator puts that line below freezing yet not flooding.
  22. Replies
    12
    Views
    2,380

    I still have a drum of R-12 just for Freezers!

    I still have a drum of R-12 just for Freezers!
  23. Replies
    12
    Views
    2,380

    Not bad. Only a 6 year old thread! How old...

    Not bad. Only a 6 year old thread!

    How old is this equipment?
  24. Replies
    7
    Views
    193

    You don't understand...…...ITS NOT GOING TO WORK....

    You don't understand...…...ITS NOT GOING TO WORK.

    The humidity will be too high
    The unit will short cycle
    The unitwill die in short order
    The utility bills will go up
  25. Replies
    7
    Views
    193

    The entire unit is overpowered for the unit! Why...

    The entire unit is overpowered for the unit! Why did they almost double the size? Did they also double the duct work so it can handle the extra air flow requirements? NO! That's the noise your...
  26. Replies
    10
    Views
    207

    9 volt AA

    9 volt AA
  27. https://hvac-talk.com/vbb/showthread.php?853762-Co...

    https://hvac-talk.com/vbb/showthread.php?853762-Contractors-Locator-Map

    https://heatinghelp.com/find-a-contractor/

    https://www.myhomecomfort.org/find-a-contractor/
  28. Replies
    10
    Views
    207

    That need to be done by the factory for the...

    That need to be done by the factory for the serial # of the machine
  29. Bad duct design increases the static pressure....

    Bad duct design increases the static pressure. High static kills ECM motors.
  30. Replies
    9
    Views
    303

    It was explained that using a combustion analyzer...

    It was explained that using a combustion analyzer you can see the difference between 50 air and 10 air. More so with oil because you adjust the amount of air for combustion. Is there a air...
  31. Replies
    9
    Views
    303

    Heating help dot com is having the same...

    Heating help dot com is having the same discussion. Here is NCI's instructor explaining it


    captainco Member Posts: 433
    December 8
    Is piping cold outside air directly to a burner a good...
  32. Replies
    16
    Views
    362

    :whistle:

    :whistle:
  33. I can hear the dispatcher from here...... I have...

    I can hear the dispatcher from here...... I have to send you all the way there to put a cap on! You guys are killing me!
  34. Replies
    10
    Views
    461

    That's the need for a dehumidifier and the...

    That's the need for a dehumidifier and the smallest mini!
  35. Replies
    16
    Views
    362

    They pay for the level of experience one way or...

    They pay for the level of experience one way or the another!
  36. Replies
    16
    Views
    362

    Get it from a dealer, let them install it and...

    Get it from a dealer, let them install it and warranty it. Might as well have the equipment serviced at the same time!
  37. The tech servicing your furnace should have a...

    The tech servicing your furnace should have a personal CO monitor on him! Ask him / her what its reading?

    There are several Low Level CO monitors on the market.

    Defender is one
  38. Replies
    12
    Views
    715

    What about the minimum line set length?

    What about the minimum line set length?
  39. Looks good is not even close! You need someone on...

    Looks good is not even close! You need someone on site with the proper test equipment!
  40. https://www.iuoe.org/our-locals/find-an-iuoe-local...

    https://www.iuoe.org/our-locals/find-an-iuoe-local-union

    http://www.ua.org/locals
  41. What is it shutting off on? If a safety then...

    What is it shutting off on? If a safety then there's an issue.

    When was the last time it was serviced?
  42. Replies
    15
    Views
    526

    Its the amount of air that can pass thru the...

    Its the amount of air that can pass thru the filter. 1" Pleated are advertised as being able to clean the air but that's not the purpose of the filter. Its just keep large pieces of dust and debris...
  43. Replies
    22
    Views
    690

    [QUOTE=evict;25817959] Sorry but schooling and...

    Sorry but schooling and reading is not even 1/2 of the training needed. Don't know how the test is on the left coast but here the 2 FDNY guys will chew you up and spit you out. They can smell On The...
  44. For a contractor like that paying a little more...

    For a contractor like that paying a little more is well worth it! Glad it worked out.
  45. Replies
    22
    Views
    616

    Counting the weeks until my 1st Social Security...

    Counting the weeks until my 1st Social Security check :grin2:

    Keep Contributing!
  46. Replies
    1
    Views
    153

    Anything with Minis forget the internet call the...

    Anything with Minis forget the internet call the factory!
  47. Replies
    22
    Views
    616

    Fixed :whistle:

    Fixed :whistle:
  48. Replies
    22
    Views
    616

    That's because he knows nothing!

    That's because he knows nothing!
  49. Thread: Walk in Freezer

    by pecmsg
    Replies
    14
    Views
    372

    https://hvac-talk.com/vbb/showthread.php?158850-Go...

    https://hvac-talk.com/vbb/showthread.php?158850-Got-Questions-Help-Us-Help-You-Please-Read-Before-Asking-A-Technical-Question!
  50. Replies
    15
    Views
    526

    Why turn it off? No furnace is designed for that...

    Why turn it off? No furnace is designed for that large of a temperature swing! Id also add any larger swing and there could be condensation issues.
    Loose the Pleated furnace killing filter, the air...