Search:

Type: Posts; User: ChillerR123

Page 1 of 3 1 2 3

Search: Search took 0.03 seconds.

  1. Replies
    2
    Views
    408

    Cool, I'll check them out. Thanks.

    Cool, I'll check them out.

    Thanks.
  2. Replies
    2
    Views
    408

    Tridium Graphics - Widgets

    Hi All,

    I am doing a simple project (as simple as Tridium can be) with a JACE 8000, and wanted to display some graphs of recorded points.

    Does anyone have any suggestions for a better graphics...
  3. Carrier Chillers - Oil Return Techniques - 19XR

    Hi All (and Merry Christmas),

    Easy question, what are your thoughts / techniques on returning oil to an oil sump?

    ie: the oil tank level is below the bottom sight glass:
    - do you add oil to...
  4. Replies
    13
    Views
    907

    Hi carriermechanic, I'll PM you.

    Hi carriermechanic, I'll PM you.
  5. Replies
    13
    Views
    907

    WYLBEK, yep, I think so. From what i know, the...

    WYLBEK, yep, I think so. From what i know, the insides of a 19XR is almost the same as a 19XL? You wouldn't have a tear down manual handy by chance? I'll check my folder of manuals too!!
  6. Triple evac - less than 500 microns - good...

    Triple evac - less than 500 microns - good standing test - like 24hrs (is possible).
  7. Replies
    13
    Views
    907

    Hi Pumpdown, thanks for your reply. I didn't want...

    Hi Pumpdown, thanks for your reply. I didn't want to load up with too much info too soon. Oil pressure is about 200kPa delta T, so this is a little high, but certainly not low, so no indications of a...
  8. Replies
    13
    Views
    907

    Ok. There is history of heaps of surges, and it...

    Ok. There is history of heaps of surges, and it had been running at super low load (from old logs i found). What would be a test procedure for confirming this? - PM if too much info for open forum :)
  9. Replies
    13
    Views
    907

    Scratch that... not the suction elbow.

    Scratch that... not the suction elbow.
  10. Replies
    13
    Views
    907

    Hi JEF1980, I was hoping for your reply :) ...

    Hi JEF1980, I was hoping for your reply :)

    Mate I don't know if has - but looking at the paint on the bolts, it looks quiet original. My suspensions is that something has let go inside. If this is...
  11. Replies
    13
    Views
    907

    Carrier 19XRV - Oil Return Problem

    Hi All Carrier Experts,

    I have just picked up 2 x 19XRV 1012 237BFS52S Ė apparently, they have history, but no one can tell me exactly what??

    I am experiencing a problem on one of them with oil...
  12. Replies
    8
    Views
    839

    Hi Lads, I've tried that direct connection...

    Hi Lads,

    I've tried that direct connection Gibbo - direct to the PIC6 display screen (CCN terminals) but with no luck - methodically tried heaps of ranges too. I've connected to some many Carriers...
  13. Replies
    8
    Views
    839

    Carrier - PIC 6 - 19XRV

    Hi All,

    So, I have a problem... I have a new 2018 19XRV that I simply cannot access - none of the standard passwords work (1111 for service) I cannot find any BUS or ELEMENTs when I connect my...
  14. Replies
    0
    Views
    398

    Geoclima - Chiller IOM's

    Hi All,

    Can anyone share some information on Geoclima chillers - mainly IOM's for the air cooled scroll range.

    The website looks fancy, but the available info is very limited.


    Thanks...
  15. Trane RTHB - Chiller High Level Interface (HLI) comms to BMS

    Hi Trane experts,

    I have an RTHB, is there any new products / modules being used to read the chiller data - (like via COMM4), or is it still the same old COMMS module?


    Thanks.
  16. Replies
    10
    Views
    1,497

    I've seen oil in DTC's before, more than once...

    I've seen oil in DTC's before, more than once too!! It's never a "purposely done" factory thing, but it is partly related to purchasing cheap refrigerant from cheap suppliers. I have seen the...
  17. Replies
    12
    Views
    770

    nice... you can PM me if need be. Cheers.

    nice... you can PM me if need be.


    Cheers.
  18. Replies
    12
    Views
    770

    So the main ones are: - 19XRV - 30HXC - 30XA ...

    So the main ones are:
    - 19XRV
    - 30HXC
    - 30XA

    I have 3 x carriers with their current 33CNTRAN485 / HLI cards failed. I wanted to upgrade to the new OPN-UPC.
  19. Replies
    12
    Views
    770

    Unless you have?

    Unless you have?
  20. Replies
    12
    Views
    770

    Thanks mate :) Iíll see if I can download...

    Thanks mate :)

    Iíll see if I can download these from HVAC Partners.
  21. Replies
    12
    Views
    770

    Ok, cool. What is the program I need to for field...

    Ok, cool. What is the program I need to for field configuration / programming?
  22. Replies
    12
    Views
    770

    Hi CB38, so if you have NSTV it is possible to...

    Hi CB38, so if you have NSTV it is possible to configure without factory support? I donít need graphics, I just want to map the points via Bacnet.
  23. Replies
    12
    Views
    770

    Carrier - OPN-UPC - Field Installation

    Hi All,

    Just wondering if anyone has used the Carrier OPN-UPC BACnet interface card? High Level Interface from chiller to BMS.

    I am interested if it will integrate with older Carrier chillers,...
  24. Replies
    3
    Views
    845

    Hi mate, yes, it has the Siemens colour touch...

    Hi mate, yes, it has the Siemens colour touch screen & a heap of Siemens modules in the panel too. Any info would we great!
  25. Replies
    3
    Views
    845

    Thermax Absorption Chiller - Info

    Hello All,

    Can anyone assist with information relating to a Thermax LT16C ? Hot water driven, but I would like to know a little more about this particular chiller.

    Any info would be...
  26. Replies
    4
    Views
    1,359

    Yep, you'll be up & running in 8hrs... so long as...

    Yep, you'll be up & running in 8hrs... so long as it isn't a demagged shaft :)
  27. Replies
    0
    Views
    529

    TU - 9.4 Balance Tool Program

    Hi All, open forum question...

    Anyone keen to drop me a copy of 9.4.94 - happy for it to be the Balance Tool.


    Thanks.
  28. Replies
    43
    Views
    5,999

    Yeah right... see Nucl, I keep learning!! ...

    Yeah right... see Nucl, I keep learning!!


    Sent from my iPhone using Tapatalk
  29. Replies
    43
    Views
    5,999

    Hi Nuclrchiller, no need for apologies!! If only...

    Hi Nuclrchiller, no need for apologies!! If only I could remember all I ever did too, I would be... something?? Yes, place a pointy finger in the middle of the screen and keep it there, power up the...
  30. Replies
    43
    Views
    5,999

    Good Day All, So, the CGAM nightmare is...

    Good Day All,

    So, the CGAM nightmare is over... the job is done, both chillers are configured perfectly & running like a dream.

    Solution, don't trust the CGAM software!! It took some several...
  31. Replies
    43
    Views
    5,999

    So to answer my own question, to fix this problem...

    So to answer my own question, to fix this problem (when it doesn't reset after 15mins) is to hold your finger in the middle of the screen during start up... the rest is magic!!
  32. Replies
    43
    Views
    5,999

    So an update lads... I am configuring my...

    So an update lads...

    I am configuring my replacement (spare) CH530 on our test rig, so to avoid several trips to site...

    It appears when I configure it exactly as per the name plate, the CH530...
  33. Replies
    1
    Views
    711

    RC Group - Frigo Turbo FL chillers

    Good Afternoon All,

    Does anyone have an IOM or any decent literature on RC Group - Frigo Turbo FL chillers?

    If you haven't seen them, it is an Italian built water cooled chiller with a TT300...
  34. Replies
    43
    Views
    5,999

    nope, just CGAM... or CGAX. I would love to make...

    nope, just CGAM... or CGAX. I would love to make it an RTAC!!
  35. Replies
    43
    Views
    5,999

    Man the last time I used Rover it was to...

    Man the last time I used Rover it was to configure VAV's... a very distant memory. I don't have that converter anymore.

    I do have access to TU though, but surely this isn't able to connect to a...
  36. Replies
    43
    Views
    5,999

    sorry, I meant the incorrect Java installed... I...

    sorry, I meant the incorrect Java installed... I swear that what I type doesn't translate to the screen!!
  37. Replies
    43
    Views
    5,999

    I am all over Java Update... but yes, if you have...

    I am all over Java Update... but yes, if you have the correct Java installed, this will make techview not work at all.
  38. Replies
    43
    Views
    5,999

    Thanks for all the input guys, and really valid...

    Thanks for all the input guys, and really valid notes there... just so you don't think I am completely useless (and I am not taking or implying any offence) I am competent with the Trane products &...
  39. Replies
    43
    Views
    5,999

    Hi All, so I can certainly confirm that I haven't...

    Hi All, so I can certainly confirm that I haven't misread the O vs 0 and also the l vs 1.

    I also have used the version 13 CGAM software too... same result.

    There is another CGAM on this site,...
  40. Replies
    43
    Views
    5,999

    Hi 77, The CH530 is fried... so nothing able...

    Hi 77,

    The CH530 is fried... so nothing able to be recovered (this was my first hope). So I had to configure it from scratch. The tonnage is set under Unit Capacity - (80 Nominal Tons). There is...
  41. Replies
    10
    Views
    2,569

    We use putty with success... I use a serial cable...

    We use putty with success... I use a serial cable with a USB converter for the laptop... cut off one end of the serial cable and then pin out the colours to the pin numbers (pin out yeah!!) this is...
  42. Replies
    43
    Views
    5,999

    Trane CGAM - Configuration Nightmare!!

    Hi All,

    Can anyone help me with configuring a CGAM?? It its killing me.

    I have configured many CH530's over the years with no problems (RTAC's CVHF's, RTHD's)

    This one is a Chinese built...
  43. Replies
    8
    Views
    1,811

    Hi spinning wheel, do you have a PM??

    Hi spinning wheel, do you have a PM??
  44. Trane UC400 vs Trane BCI-C - HLI Question

    Hi All,

    I have been asked to install a HLI for a Trane RTHD (CH530). Can anyone confirm which module to use - either the UC400 module or a BCI-C (similar looking to a UC400) ?

    I know the BCI-C...
  45. Replies
    7
    Views
    2,390

    oh, are you saying upgrade the software on the...

    oh, are you saying upgrade the software on the CH530? I have done that on the other chiller onsite & it now works great. I was keen to see if there were any site specific settings before I wiped it...
  46. Replies
    7
    Views
    2,390

    I am running 14.6 and the age of this chiller...

    I am running 14.6 and the age of this chiller should fall well within that range. I see that service pack 14.9 is now available, so I will try that and see what happens.

    Thanks for reply ACJ...
  47. Replies
    8
    Views
    1,811

    Oh, but without being connected to Carrier, this...

    Oh, but without being connected to Carrier, this proves difficult. Do you have any recommendations on how to set up a user name / password?
  48. Replies
    7
    Views
    2,390

    Techview / CH530 Problem?

    Hi All,

    I recently worked on 2 x new Trane CGAM's (built in China). I could connect locally to the CH530 just fine, but it then Techview displayed "No Configuration / Configuration is not valid"? ...
  49. Replies
    27
    Views
    4,069

    Loctite 515 (master gasket) or 277 (thread...

    Loctite 515 (master gasket) or 277 (thread locker) is all I have ever used - works every time (however the system has always been at 0kPa)

    The amount of flare nuts I have seen covered with the...
  50. Replies
    8
    Views
    1,811

    Hi Spinning Wheel, What software are you...

    Hi Spinning Wheel,

    What software are you referring to that you can download & install from the Carrier website??

    Our company has several NSTV's & find them extremely useful for Carriers of all...
Results 1 to 50 of 127
Page 1 of 3 1 2 3