Search:

Type: Posts; User: dan sw fl

Page 1 of 20 1 2 3 4

Search: Search took 0.53 seconds.

  1. Replies
    16
    Views
    264

    ASHRAE DEHUMIDIFICATION _____ 1% __ 61.2'F Dew...

    ASHRAE DEHUMIDIFICATION
    _____ 1% __ 61.2'F Dew Point __
    ___________ 82.4 Humidity Ratio {HR}
    ___________ 73.3'F Mean Coincident Dry Bulb {MCDB}

    The amount of moisture being removed
    should...
  2. BEWARE.!

    https://s3.amazonaws.com/WebPartners/ProductDocuments/B56A6599-E6CE-4715-8F22-508D633C3EFA.pdf

    ___ :payattention: ___

    DOMESTIC HOT WATER
    GENERALLY OPERATES AT ~ 125'F MAXIMUM

    ...
  3. Replies
    9
    Views
    190

    IS A 100,000 BTU/HR furnace required ? ...

    IS A 100,000 BTU/HR furnace required ?

    https://resource.gemaire.com/is/content/Watscocom/Gemaire/rheem_ra1642aj1na_article_1405358021510_en_ss.pdf?fmt=pdf
  4. Replies
    16
    Views
    264

    PRELIMINARY Model of THERMAL ENVELOPE - 2,967 SQ FT

    Does this information on the MY CALC INPUT FORM closely represent Your planned residence?

    NOT REALLY, a NORTH arrow and the Window Schedule have Not been provided.
  5. Replies
    16
    Views
    264

    Documentation of Equipment Configuration and Simulated Performance Analysis

    … … … ____ _____ Not adhering to WA state statues falls into that Same category.

    SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)

    R405.4.2 Compliance report
    _____ The...
  6. Replies
    16
    Views
    264

    ABSOLUTELY NOT.!..!! ANY POSTULATED SAVINGS...

    ABSOLUTELY NOT.!..!!

    ANY POSTULATED SAVINGS that is REASONABLE in THIS SITUATION
    extends beyond the lifetime of the equipment.

    DESIGN ASSISTANCE: https://www.mysimplifiedhvac.com
  7. Replies
    16
    Views
    264

    In general, 0.09 / kw-hr

    In general, 0.09 / kw-hr
  8. Replies
    16
    Views
    264

    Seems like SOMEWHERE, WASHINGTON state ......

    Seems like SOMEWHERE, WASHINGTON state
    ... Climate Zone 5 or 4 Marine
    … PERHAPS CLARK COUNTY
    __ Specific ZIP would DEFINITELY be appropriate information.

    ___ Page 7 of 8 excerpt

    ...
  9. FIRST STEP

    3,015 Sq Feet, 2-story, 1996 built, ZIP 63021 - Missouri

    ACCA MANUAL J INPUT FORM
    _______________________ below
    _____ OP / Fire989, VERIFY inputs on lines 11 to 26

    GLASS, Clear :...
  10. AVOID HIGH DENSITY POPULATIONS @ALLCOST$.! ...

    AVOID HIGH DENSITY POPULATIONS @ALLCOST$.!

    https://www.carnival.com/cruise-ships.aspx
  11. MOVIN COOL https://movincool.com/cm-series/

    MOVIN COOL

    https://movincool.com/cm-series/
  12. Replies
    51
    Views
    743

    __ It's the Day Before Tomorrow, ALL Day ______...

    __ It's the Day Before Tomorrow, ALL Day
    ______ REORIENTATION

    2020
    ____ APRIL
    __________ 6
    ______________ MONDAY

    URWelcom
  13. Replies
    51
    Views
    743

    4 components = 1 Dual Fuel System 1. Regular...

    4 components = 1 Dual Fuel System

    1. Regular heating and cooling, 2 stage Heat pump, 4-Ton
    ( Tentative sizing: total amount of propane use to be determined )

    2. AUXILIARY HEAT:...
  14. Replies
    51
    Views
    743

    Post # 1 " We currently have the original HVAC...

    Post # 1
    " We currently have the original HVAC
    - 150k input propane furnace with a 4 ton central AC unit outside.
    I would like to do a dual fuel heat pump setup"

    W.A.G.: 1993 / 27 Year...
  15. Replies
    51
    Views
    743

    How many gallons of Propane have you used in ...

    How many gallons of Propane have you used in
    1. 2019- 2020 winter
    2. 2018- 2019
    3. 2017 -2018

    Has anyone ever told you what the efficiency of the Existing furnace is ?
  16. Replies
    51
    Views
    743

    SENSIBLE HEAT RATIO will be > 89% SPOKANE...

    SENSIBLE HEAT RATIO will be > 89%

    SPOKANE WA __ 47.417' N _- 117.526'
    2,267' ELEVATION

    ASHRAE 1%
    DB - 89.6'F
    WB- 61.8'F
    R.H.- 18.4 %
  17. Replies
    51
    Views
    743

    Results of a Building Thermal Model can be...

    Results of a Building Thermal Model can be compared to Your actual energy use.

    I suspect that you have 4 or 5 deliveries at ~ 400 gallons each
    based on your previous response in this thread. ...
  18. Replies
    7
    Views
    276

    .:. INADEQUATE.

    .:. INADEQUATE.

    << Does NOT meet Purolator requirement

    _____ https://www.purolatorairfilters.com/pdfs/F312-cut-sheet.pdf

    WILL a MERV 4 filter Maintain A CLEAN Coil?
  19. Replies
    51
    Views
    743

    Back-up with an Electric Generator and propane...

    Back-up with an Electric Generator and propane furnace is REQUIRED.

    One might wish/plan to operate propane furnace at < ~ 32'F ( +/- 5'F)
    with Auto Switchover.

    ELECTRICITY IS VEERY...
  20. Replies
    51
    Views
    743

    Properly operating 4-TON Heat Pump IS Adequate. ...

    Properly operating 4-TON Heat Pump IS Adequate.
    $ 1,400 for heating with Heat Pump & electric strips
    versus $ 4,000 for propane.

    Note: 1993 A/C is likely ~ 8 SEER.
    ___ New Heat Pump...
  21. Very Good .! 85'F + 60% Relative Humidity =...

    Very Good .!

    85'F + 60% Relative Humidity = Good Procedure
    _______ to MAINTAIN ALL BUILDINGS EMPTY.!

    RESULT = PROVEN.!
    ________ Humanoids Seek Comfortable Conditions.

    … … … … … … ...
  22. Replies
    51
    Views
    743

    I don't know anything about the size nor the...

    I don't know anything about the size
    nor the Building Thermal Envelope characteristics of your residence.

    1,700 Sq Feet each of 2 floors + 1,500 SF basement ?

    Perimeter __ ft x __ ft
    ...
  23. Replies
    4
    Views
    233

    https://www.ultra-aire.com/dehumidifiers/ 155H...

    https://www.ultra-aire.com/dehumidifiers/

    155H
    3,500 SQ FEET
    https://www.ultra-aire.com/pdf/Ultra-Aire-XT155H-Spec-Sheet.pdf


    OR 205H _ depends on How much ventilating air is selected?...
  24. < 75'F in the Summer is an initial concern. ...

    < 75'F in the Summer is an initial concern.

    15. see www.mysimplifiedhvac.com
    ___ Need to determine the Work Scope

    MONTHLY ( the last 12 or 24) natural gas and electricity usage would be...
  25. Replies
    173
    Views
    4,043

    If he knows what he is doing, he would have...

    If he knows what he is doing, he would have accounted for
    ALL THE DETAILS
    of his proposed insulation.

    If the walls and ceiling R-values are in the range of R-16 to R-24,
    the results of my...
  26. Replies
    69
    Views
    1,624

    I don't know anything about your situation. No...

    I don't know anything about your situation.
    No response to previous information requests were provided.


    READ
    __________
    https://www.daikin.com/products/ac/lineup/split_multi_split/
  27. Replies
    11
    Views
    320

    R-13 for ceiling should be increased to reflect...

    R-13 for ceiling should be increased to reflect the increase in insulation within a few months.
    I do not understand use of 855 sq ft for the ceiling area.

    The wall U-VALUE is stated as 0.20 on...
  28. Replies
    11
    Views
    320

    BLOCK Load __ ONLY for General Sizing of...

    BLOCK Load __ ONLY for General Sizing of Equipment

    YOUR Specific Info need on
    Lines 5, 8, 11, 12, 13, 15, 16, 18, 19, 21, 22, 23, 24, 25, 26, 30, 31, 39 & 42

    ATTACHMENT
    --------- MY...
  29. Replies
    11
    Views
    320

    SPECIFIC ASSISTANCE _ My Gmail address:...

    SPECIFIC ASSISTANCE
    _ My Gmail address: racingdan11

    Age of residence ___ Built in 1945 -- -- Or 2005 ?
    Sq feet Floor Area per Floor
    ZIP _ _ _ _ _

    Windows SHGC 0._ _ / U-factor 0._...
  30. Replies
    5
    Views
    260

    Title of the other Thread __ New Residential HVAC

    Title of the other Thread __ New Residential HVAC
  31. Replies
    8
    Views
    473

    House is 16 years old, 3500 sq ft, split level,...

    House is 16 years old,
    3500 sq ft, split level,
    Central Ohio.


    Investigate whether
    Trane: 96%, 80,000 BTU, Variable Speed A/C or Heat Pump 3.0 Ton,
    2 stage, 17 SEER is the most...
  32. This type of transition is addressed in the...

    This type of transition is addressed in the calculation procedure
    with a vast array of representative fittings.
    __ The calculation procedure is known as ACCA MANUAL D.

    I doubt that a EL...
  33. Replies
    69
    Views
    1,624

    YOU DID NOT RECEIVE A PROPOSAL. ...

    YOU DID NOT RECEIVE A PROPOSAL.

    https://www.energystar.gov/ia/home_improvement/home_contractors/qispec.pdf

    $ale$ ONLY use ONE Type of Number.
    _________________ ____________
    What you received...
  34. Replies
    173
    Views
    4,043

    CODE COMPLIANCE

    I guess one could believe
    that a Code official may NOT actually know his DIRECT Responsibilities
    regarding Texas statues and Energy Conservation.

    https://up.codes/codes/texas
    ...
  35. Replies
    173
    Views
    4,043

    Obtain calculation reults & post the Design...

    Obtain calculation reults & post the

    Design Temperature: 9 _ 'F
    Inside Temperature: 75'F

    HEAT GAIN
    Sensible ____ - BTU/HR
    __ Latent _____

    -------------------------
  36. Replies
    69
    Views
    1,624

    $ale$ ONLY use ONE Type of Number....

    $ale$ ONLY use ONE Type of Number.
    __________________


    ACCA Manual J
    __ Input Worksheet

    SIZE DEPENDS ON:

    1. AGE of residence ___ ? Built in 1977 or 2007
  37. Replies
    69
    Views
    1,624

    ACCA Manual J __ Input Worksheet SIZE...

    ACCA Manual J
    __ Input Worksheet

    SIZE DEPENDS ON:

    1. AGE of residence ___ ? Built in 1977 or 2007
    2. ZIP _ _ _ _ _
    _______ 25'N or 52'N Latitude
    --- 800 or 8,000 foot elevation
  38. Replies
    173
    Views
    4,043

    WINDOWS __ S.H.G.C. 0.17 __ U-factor 0.29 ...

    WINDOWS __ S.H.G.C. 0.17 __ U-factor 0.29
    Total glass area 92 sq feet
    ________ West _ 70
    ________ East _ 22

    Walls R-19

    Floor R-20
    Ceiling R-20
  39. Replies
    173
    Views
    4,043

    It is ONE OPTION. Good ? Seems to be An "OLD...

    It is ONE OPTION. Good ?
    Seems to be An "OLD SCHOOL" concept.

    I can only say it is a step closer to a better solution at-this-time.


    Mini-Split & Small VENTILATING Dehumidifier...
  40. Replies
    173
    Views
    4,043

    PRELIMINARY Equipment Options

    The coil is not Exactly what I had anticipated.
    Although 3.5 sq feet coil area IS TOO Large,
    a valid AHRI # actually exists, which is 8931678 paired with a 4TWR 4018 condensing unit.
    ...
  41. Replies
    173
    Views
    4,043

    POST # 3 provides a simplified Load Calculation....

    POST # 3 provides a simplified Load Calculation.

    Quite frankly, I ALSO Feel as if I have been blown off.
  42. Replies
    16
    Views
    569

    WHY would you presume it is Not required by...

    WHY would you presume
    it is Not required by code?
  43. Replies
    16
    Views
    569

    IF you really wish to KNOW about a more accurate...

    IF you really wish to KNOW about a more accurate and Appropriate thermal model
    you can provide:

    1. monthly utility bills/ ENERGY USAGE
    2. Infiltration amount (A.C.H. Natural ) from a Your...
  44. Replies
    16
    Views
    569

    Bonus Rooms are problematic > 98% of the time. ...

    Bonus Rooms are problematic > 98% of the time.

    Bonus Room = FROG
    _________ Finished Room Over Garage
  45. Replies
    24
    Views
    765

    Central NC _________ Is your house < 20 years...

    Central NC
    _________ Is your house < 20 years old ?

    __ > 1,800 Sq.Feet ?
    __ > 2,400 Sq.Feet ?
    __ > 3,000 Sq.Feet ?

    ___ 2-Story ?

    __ > 200 Sq feet of Windows
  46. Replies
    16
    Views
    569

    Model can be verified using MY CALC personal...

    Model can be verified using MY CALC personal software
    along with at least 12 months of energy use / actual utility bills.

    Equipment selections and operating cost evaluations
    require an...
  47. Replies
    16
    Views
    569

    Alternate Temp.

    13'F
    65 CFM

    53,300 BTU/HR
  48. Replies
    16
    Views
    569

    Check

    __ 87'F
    Duct model: AVERAGE ( or perhaps Good ?)
    Floors _____ R-4

    Construction: Good
    ___ Infiltration: _ ~ 70 CFM
    ___ Fresh Air: 84 CFM

    Windows - half of them shaded
  49. Replies
    19
    Views
    756

    I am not familiar with the location "nearby us in...

    I am not familiar with the location "nearby us in TX" .
    ___________________________ DWF ?

    TX = 268,820 sq miles __ a.k.a. NOT Small

    I don't know which sq mile Her House in located in.
  50. Replies
    173
    Views
    4,043

    You must ditch this proposal and the contracting...

    You must ditch this proposal and the contracting firm.

    A Valid Proposal shall have equipment about 1/3rd of the proposed size.
    ______________________________ --- __ ~ 1- Ton Heat Pump with Air...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4