Search:

Type: Posts; User: dandyme

Page 1 of 20 1 2 3 4

Search: Search took 0.11 seconds.

  1. Replies
    9
    Views
    521

    Tell your co worker to go ahead and run that...

    Tell your co worker to go ahead and run that adjustable pulley in the point that the belt rides a larger arch than the motor stator, then sit back and watch what happens.
  2. Replies
    1
    Views
    201

    Thank you Don Sleeth

    For 20 years

    816369

    816370

    Bring back Snuffy.
  3. Replies
    11
    Views
    371

    Have installing contractor provide documentation...

    Have installing contractor provide documentation from manufacturer that the actual clearances are acceptable. Most manufacturers have "extreme exceptions" that are not publicized but are provided...
  4. Replies
    3
    Views
    195

    Zoned (up/down) system maybe??

    Zoned (up/down) system maybe??
  5. Replies
    4
    Views
    213

    That RJ14 connector is for the service tool...

    That RJ14 connector is for the service tool connection, from what I could see from IOM.
  6. Replies
    24
    Views
    592

    815978 your procedure for checking is accurate.

    815978
    your procedure for checking is accurate.
  7. Replies
    4
    Views
    213

    Ask Our Pros-Owner Assistance - NO DIY advice...

    Ask Our Pros-Owner Assistance - NO DIY advice will be given.
  8. It looks like that drain goes uphill.

    It looks like that drain goes uphill.
  9. Replies
    44
    Views
    1,798

    ::DD: Remember being told by manufacturers...

    ::DD:

    Remember being told by manufacturers tech trainers, and these guys were upper caliber, "your running that refrigerant through the manifold, a 1/4" hose, a valve core depressor & valve core,...
  10. Replies
    44
    Views
    1,798

    The short answer is NO. This is an open forum....

    The short answer is NO. This is an open forum. Here is a clue: when both pressures are at equal all action ceases
  11. Is that thing cooling a control panel? That's the...

    Is that thing cooling a control panel? That's the only place I've seen McLean unit.
  12. What area of NC?

    What area of NC?
  13. Replies
    2
    Views
    356

    Caught a webinar from Mitsubishi, looks to be the...

    Caught a webinar from Mitsubishi, looks to be the go to refrigerant for chillers.
  14. Replies
    10
    Views
    505

    Is the condensate pump breaking the"S" signal? ...

    Is the condensate pump breaking the"S" signal? That's not good, should be breaking L2.
    815385
  15. Replies
    17
    Views
    1,054

    .

    .
  16. Replies
    17
    Views
    1,054

    You guys have been active today. I report to the...

    You guys have been active today. I report to the service manager. Only a small portion of our responsibilities overlap, very small. As I told a supervisor years ago, "I've worked for bigger *******s...
  17. Replies
    17
    Views
    1,054

    Any questions will have to directed to the...

    Any questions will have to directed to the website listed. I've never thought much of an individual that; the first question out of their mouth is " how much.....(money, vacation, ect.) You are...
  18. Replies
    17
    Views
    1,054

    Service Manager

    Position will become open May/June.
    www.loganhvac.com
  19. Replies
    17
    Views
    460

    Well, since it appears that "A" is reusing...

    Well, since it appears that "A" is reusing existing furnace, someone may want to verify the blower is of adequate size.
    Both "A & B" are under the United Technologies umbrella.
  20. Replies
    34
    Views
    1,568

    that is what got this post reported and also...

    that is what got this post reported and also garnered the comment.
  21. Replies
    34
    Views
    1,568

    You might want to call a service tech to...

    You might want to call a service tech to determine what the malfunction is.
  22. Daikin and Toshiba make their own equipment. Find...

    Daikin and Toshiba make their own equipment. Find out what manufacturer produces the Trane and Rheem units. These like many products have only a limited number of manufacturers compared to infinite...
  23. You are listed as a homeowner. What does your...

    You are listed as a homeowner.
    What does your contractor suggest?
  24. Replies
    29
    Views
    3,664

    Heating, Units Without Economizer 04A--07A...

    Heating, Units Without Economizer 04A--07A (single compressor model): When the thermostat calls for heating, terminal W1 is energized. DFB receives this input at P2Ė7. The DFB removes the output at...
  25. Replies
    9
    Views
    1,128

    Did NEC change from ALL wiring in conduit MUST...

    Did NEC change from ALL wiring in conduit MUST have same rated insulation? The intent of that is to prevent electrical interference/electric field generation.
  26. Replies
    29
    Views
    3,664

    This is a GEMINI series machine. 1- t-stat HAS...

    This is a GEMINI series machine.
    1- t-stat HAS to be configured as ELECTRIC HEAT.
    2- DO NOT set heat cycle rate above 5, 4 is better. If set higher than 5 cph the control board will see this as a...
  27. He gone.

    He gone.
  28. When the need arises for a service call again;...

    When the need arises for a service call again; when you place that call, ask the perspective organization if their technicians have adequate test instruments. Unless a LOT was left out of your...
  29. Replies
    3
    Views
    394

    ....and what kind of webinar or virtual event is...

    ....and what kind of webinar or virtual event is this???
  30. Replies
    29
    Views
    3,664

    Is this a GEMINI unit?

    Is this a GEMINI unit?
  31. Thread: New here

    by dandyme
    Replies
    7
    Views
    2,116

    I want to know what is the prize since this is in...

    I want to know what is the prize since this is in CONTEST! CONTEST!?
  32. Replies
    23
    Views
    608

    "AC Ready Kit", that's a different name for it....

    "AC Ready Kit", that's a different name for it. Please tell us the tech didn't call it that.
  33. thought they stated #1 is on, oh well.

    thought they stated #1 is on, oh well.
  34. The manual indicates that when switch #! is in ON...

    The manual indicates that when switch #! is in ON position, the unit is in EMERGENCY HEAT, your electric heat is the only heat operating.
  35. Replies
    2
    Views
    772

    Didn't read the rules you agreed to when signing...

    Didn't read the rules you agreed to when signing onto site did you.
    Pricing NOT ALLOWED.
  36. Are you sure that #1 compressor is capable of...

    Are you sure that #1 compressor is capable of operating?
  37. Replies
    22
    Views
    1,010

    Here daily mostly. Discouraging to see the newer...

    Here daily mostly. Discouraging to see the newer "techs" have no inkling how to troubleshoot, but have no problem coming here and wanting solution to their problem, almost like a homeowner. These...
  38. acetylene above 15# psi will try to come out as a...

    acetylene above 15# psi will try to come out as a liquid, EXPLOSIVE.
    my normal set up: oxy 10-15# unless cutting tip in use, acty: no more than 7#.

    If you are ever really bored, inflate a balloon...
  39. Replies
    66
    Views
    3,662

    Because we don't like you. :spitball::gah::beat:

    Because we don't like you. :spitball::gah::beat:
  40. Thanks for the heads up. #BringBackCoolKwiz

    Thanks for the heads up.
    #BringBackCoolKwiz
  41. Is this unit under warranty??? If yes, call your...

    Is this unit under warranty???
    If yes, call your installer and stop playing with things that may hurt you.
    If no, call a service company if you have "issues" with installing contractor.
  42. Replies
    10
    Views
    1,459

    Poor thing was tired and needed a nap.

    Poor thing was tired and needed a nap.
  43. Replies
    7
    Views
    786

    Same effect. Pressure differential. Never seen...

    Same effect. Pressure differential. Never seen mono flo tee for cast iron.
  44. Replies
    32
    Views
    3,398

    Unless that is the exterior wall? "This...

    Unless that is the exterior wall?
    "This accessory must be used only for terminating the vent of a Category IV furnace. Do not use this termination kit for any other type furnace. Failure to follow...
  45. Replies
    24
    Views
    1,914

    1-why is the pressure "creeping up" once the...

    1-why is the pressure "creeping up" once the solenoids open?
    2-just what kind of time delay between contactors pulling in?
  46. Replies
    6
    Views
    407

    Is the system NOT under warranty?

    Is the system NOT under warranty?
  47. If a job is posted and one wants to know the...

    If a job is posted and one wants to know the answers to those questions; if one was motivated enough they would contact the party posting the job.
    So many times I've notified someone of a job...
  48. 1-Did not see design conditions? 2-Does it get...

    1-Did not see design conditions?
    2-Does it get below freezing?
    2a-Did mfg remove criteria of insulating venting in area subject to freezing temps?
    2b-Is that drain line going to be insulated/heat...
  49. Replies
    10
    Views
    486

    The equipment will have to rated for manufactured...

    The equipment will have to rated for manufactured housing unless your duct work is replaced.
    Coleman is rated, trane was at one time, there are probably others.
  50. Replies
    12
    Views
    1,292

    are those 2 questions your addy? otherwise, did...

    are those 2 questions your addy?
    otherwise, did not see it.
Results 1 to 50 of 1000