  1. Replies
    2
    Views
    91

    I say the same as pecmsg, dual fuel with a...

    I say the same as pecmsg, dual fuel with a somewhat basic 80% furnace ( Hybrid System ) try bumping up the HSPF to 8.5 as you have a better chance at the federal tax credit and rebates.
  2. Replies
    29
    Views
    540

    What did they say about a float switch or a drain...

    What did they say about a float switch or a drain on the auxiliary pan, whatís the next step from the Contractor?
  3. Replies
    9
    Views
    189

    Many economizers on RTU is another big thing....

    Many economizers on RTU is another big thing. Whether they work correctly or not is another story.
  4. Replies
    1
    Views
    70

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&so...

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwjAjJzAh9XpAhWQWM0KHf1LA_wQFjABegQIAhAB&url=https%3A%2F%2Fwww.trane.com%2Fcontent%2Fdam%2FTrane%2FCommercial%2Fglobal%2Fproduct...
  5. Does the specifications/features of this year...

    Does the specifications/features of this year model ( says 2020 on bottom of page ) is the same as what you have?

    Have whoever you hire pick a OD unit from the AHRI web-site to match to your ID...
  6. https://www.google.com/url?sa=t&rct=j&q=&esrc=s&so...

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwi33pjm-9TpAhXRbc0KHQ5jBI8QFjAAegQIAhAB&url=https%3A%2F%2Fwww.tempstar.com%2Fen%2Fus%2Fproducts%2Ffan-coils%2Ffvm4x%2F&usg=AOvV...
  7. Replies
    10
    Views
    180

    Well...your thinking of getting a Heat Pump...

    Well...your thinking of getting a Heat Pump anyway so that part is a wash, a no frill 80% furnace is not terribly expense, to install heating elements require extra heavy gauge wires feeding the Air...
  8. Replies
    10
    Views
    180

    As an option put in a Hybrid system, a no frill...

    As an option put in a Hybrid system, a no frill 80% furnace, and a Heat Pump. Below a certain OD temperature the furnace comes on, above a certain OD temperature it switches to Heat Pump Mode, no...
  9. https://www.google.com/url?sa=t&rct=j&q=&esrc=s&so...

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwi9oonpstTpAhWQbc0KHQELB-oQFjABegQIBBAB&url=https%3A%2F%2Fwww.rheem.com%2Finnovations%2Finnovation_residential%2Fintegrated_sys...
  10. Replies
    45
    Views
    631

    I would ask him for the piston metering device...

    I would ask him for the piston metering device that’s he is removing, to install the TXV as if all the literature that was sent you is correct and the piston that came with the coil was used, the...
  11. Replies
    1
    Views
    75

    The fan center typically consists of a relay and...

    The fan center typically consists of a relay and transformer package. The transformer also gets warm/hot even the relay coil, If it has high voltage terminal hook ups on the relay, believe it’s...
  12. Replies
    7
    Views
    245

    It’s not uncommon to insulate the plenum to...

    It’s not uncommon to insulate the plenum to prevent the sweating, the 10 year warranty is not from them ( unless your talking a labor warranty ) a 10 year compressor and parts warranty is provided by...
  13. Replies
    45
    Views
    631

    Well,...hopefully the TXV and subcooling...

    Well,...hopefully the TXV and subcooling adjustment and whatever else he does solves your problem. Can’t do a whole lot until repairs are made... when do you expect him back?
  14. Replies
    29
    Views
    540

    You should take care of the auxiliary drain pan,...

    You should take care of the auxiliary drain pan, have them install a sensor of some sort in there to shut system off, before damage is done.

    Call out the crack HVAC company who installed it,...
  15. Replies
    45
    Views
    631

    15 degree difference, you at least got a number...

    15 degree difference, you at least got a number to compare when he does his thing whenever he comes back out. Ask yourself what was the OD and ID temperature when he got that number, did he let the...
  16. Replies
    5
    Views
    112

    Here’s one free one ...

    Here’s one free one
    ...
  17. Replies
    45
    Views
    631

    Maybe it was a relatively cooler days? Who knows..

    Maybe it was a relatively cooler days? Who knows..
  18. Replies
    45
    Views
    631

    If the Tech. Is going to install a TXV kit...

    If the Tech. Is going to install a TXV kit hopefully it’s rated for your system, at 4 ton. Also you don’t replace the piston, you remove the existing one when installing the TXV. Make sure he gives...
  19. Replies
    12
    Views
    291

    May want to have the Tech. call Technical Service...

    May want to have the Tech. call Technical Service or some other department of Maytag/Nortek if they can’t find it on your internet search. Have them show the photo and model and serial number. A...
  20. Replies
    12
    Views
    215

    .

    .
  21. Replies
    12
    Views
    339

    If your as good as you say you are and have...

    If your as good as you say you are and have attention to detail, very few call backs, ( don’t smash up the service trucks regularly :whistle: ) excellent attendance, strong work ethic, all that good...
  22. You can try to buy some self adhesive felt...

    You can try to buy some self adhesive felt insulation ( after cleaning general area ) depending on age of that unit it could easily ( insulation ) deteriorated over the years.

    The ones I’ve seen...
  23. Would have been nice if the retired Tech. gave...

    Would have been nice if the retired Tech. gave you a recommendation of a reputable knowledgeable HVAC person, as tradespeople network typically.
  24. So your saying ( with system at off position at...

    So your saying ( with system at off position at the t-stat ) if you just put the blower fan to ON position, the blower fan comes on, nothing else yes? If so then if you leave the fan switch at the...
  25. If you put the fan to ON position and the A/C on...

    If you put the fan to ON position and the A/C on does the A/C stay on or even come on and it cools the residence? If so should not be a difficult fix. At 50 years old, the wiring and operation got to...
  26. Replies
    12
    Views
    339

    $7.00 dollar increase in 3 years...not to shabby....

    $7.00 dollar increase in 3 years...not to shabby. Maybe this person has more licenses or higher tier license than you. Maybe the benefit package that this person has is not as generous as yours....
  27. Replies
    27
    Views
    432

    They should be checking your charge according to...

    They should be checking your charge according to this manufacturers chart, page 12. The airflow to page 10, next time they come out. Dated 2011, close to when your unit was built and properly current...
  28. Replies
    27
    Views
    432

    Guessing they probably buried the cost into the...

    Guessing they probably buried the cost into the labor as itís such a low dollar item if they said it was under warranty?
  29. Replies
    27
    Views
    432

    Check to make sure you can see completely through...

    Check to make sure you can see completely through the coil, and not just the outside surface area looks clean.
  30. Replies
    27
    Views
    432

    If you registered your unit, you get a 10/10...

    If you registered your unit, you get a 10/10 compressor and parts warranty and that capacitor should not cost you anything.
  31. Replies
    27
    Views
    432

    Why should refrigerant be added if there is no...

    Why should refrigerant be added if there is no leak, considering it worked great the 1st four years?

    If ductwork is truly sealed properly, blower speed set correctly, return sized correctly.
    ...
  32. Replies
    27
    Views
    432

    So you had 4 Techs. out and that’s all they did,...

    So you had 4 Techs. out and that’s all they did, nothing about changing blower speeds, adding/removing refrigerant etc.

    How about regular PM checks did you ever have any done the 4th year? as you...
  33. Replies
    27
    Views
    432

    This ones dated 2011 says you have a PSC blower...

    This ones dated 2011 says you have a PSC blower motor, the 5 ton has the EEM motor. Says it’s a three speed.
    ...
  34. Replies
    27
    Views
    432

    What model number is the unit. If you have a...

    What model number is the unit. If you have a basic PSC motor and even the ECM motor they are multi tapped blower speed.

    What did all the invoices they gave you said in regards to what they did?
  35. Replies
    27
    Views
    432

    Guessing they changed the blower speed to get...

    Guessing they changed the blower speed to get that 21-25 degree differential? If they changed the blower speed to get those numbers what was it before the change, as guessing it was set at a higher...
  36. The thing sticking up on your copper line with...

    The thing sticking up on your copper line with the two wires ( last photo ) is your low pressure safety control.....if you also have one on the smaller diameter copper line, that’s your high pressure...
  37. Replies
    29
    Views
    540

    Are you a daring person? Easy enough to find out,...

    Are you a daring person? Easy enough to find out, stick a thin dull tipped rod 2”-3” in away from the coil, on upper part away from the lineset connections, if it goes in that far it’s Fiberboard, if...
  38. Replies
    3
    Views
    144

    Do a load calculation to see what you need, there...

    Do a load calculation to see what you need, there are free ones online. What did the Contractor say about your existing ductwork, can it handle a slightly larger tonnage system? Does your existing...
  39. Replies
    29
    Views
    540

    Hopefully you can get satisfaction from the...

    Hopefully you can get satisfaction from the installing Contractor in getting your system running properly. Hopefully your system got registered as manufacturers warranty decreases significantly if...
  40. Replies
    29
    Views
    540

    Looks like the plenum is made from fiberboard...

    Looks like the plenum is made from fiberboard from here, covered in a bunch of foil tape, and mastic sealing. Or it could be fiberboard covering the sheetmetal Plenum to keep the metal from...
  41. Replies
    29
    Views
    540

    ďAnother time the drain pan overflowed and water...

    ďAnother time the drain pan overflowed and water leaked through the attic decking and living area drywall. The condensation line was clogged, it turns out, though the installer said he'd cloroxed it...
  42. Hopefully once you get your system dialed in from...

    Hopefully once you get your system dialed in from the Contractor, and have them give you some scenarios. Hopefully they registered your system, as Daikin gives an outstanding manufacturer warranty (...
  43. Didn’t the installing Contractor explain all the...

    Didn’t the installing Contractor explain all the different sequences of operation scenarios before leaving? If not give them a call. What is the switchover temperature, 40 degrees?

    Did they check...
  44. Replies
    2
    Views
    138

    Pretty much all manufacturers offer a aluminum...

    Pretty much all manufacturers offer a aluminum indoor coil. Thinking if bidding Contractors bids a ADP or Aspen indoor coil, your likelihood of getting a copper coil may increase.

    Rust on a indoor...
  45. Replies
    16
    Views
    255

    [QUOTE=markg1;25871141]i asked for the matched...

    [QUOTE=markg1;25871141]i asked for the matched set, guess i am in for a fight since the AHRI allows for the match. thanks for the help, at least i know it will work, just cost me more long...
  46. Replies
    16
    Views
    255

    You can use that also as it’s a active AHRI match...

    You can use that also as it’s a active AHRI match # 203372590 gives 14.5 SEER and a slightly higher EER at 12.5.

    It’s your money, you can request any combination.
  47. Replies
    16
    Views
    255

    AHRI number 203372591 shows it’s a match. Says...

    AHRI number 203372591 shows it’s a match. Says 14.5 SEER and 12 EER.
    ...
  48. Replies
    45
    Views
    631

    Or you can use Aspen TXV number 4204 ( X6-5 kit )...

    Or you can use Aspen TXV number 4204 ( X6-5 kit ) which is a 20% bleed. The 4202 is not a non bleed if you go TXV.

    If you go TXV, follow the install guide of the Goodman outdoor unit, they...
  49. Replies
    45
    Views
    631

    That coil is not a AHRI match as it does not list...

    That coil is not a AHRI match as it does not list the CM48E3F, it lists the CM48E34 as a match. Which has the TXV. 4=TXV

    All you got to do is install a OEM field install R410A TXV on your existing...
  50. Replies
    45
    Views
    631

    http://aspenmfg.com/Content_Matrix/Spec_Sheets/CM-...

    http://aspenmfg.com/Content_Matrix/Spec_Sheets/CM-SS-102519.pdf

    Unless I’m reading something differently, says that factory piston metering device the “F” in the Aspen model number Is for R22 and...