  1. Our flat rate service pricing would charge you...

    Our flat rate service pricing would charge you more to fix than you paid for it but if you found a 1 man shop with no overhead or a retired guy that still tinkers, might be worth it.

    Those...
  2. Replies
    2
    Views
    70

    One thing that scares me with variable speed...

    One thing that scares me with variable speed units: if not zoned, you can have air velocity issues on low levels getting heating & cooling to distant rooms. May not be as much of an issue in a 1...
  3. Replies
    1
    Views
    58

    The Comfort is a bare bones model. No cabinet to...

    The Comfort is a bare bones model. No cabinet to protect the coil, no pressure switches to protect the compressor. You're probably running 14 SEER with the variable speed air handler. So going up to...
  4. As far as I recall, the Ylo is for the 2...

    As far as I recall, the Ylo is for the 2 compressor units. Not used with the unloading scroll of the XR17. It used the BK but didn't go to BK on the thermostat. Also, some hack is using the timer for...
  5. Replies
    12
    Views
    163

    Looks like an old Addison Product beast. They...

    Looks like an old Addison Product beast. They made for Sears but would put a Sears serial number on it which started out 769.something.

    If we change a furnace and leave a clunker A/C behind, we...
  6. Replies
    2
    Views
    76

    Heil A/Cs too. Sounds normal to me. Are they both...

    Heil A/Cs too. Sounds normal to me. Are they both identical looking?
  7. Joey always beats me to it :D We had a job...

    Joey always beats me to it :D

    We had a job many years ago where house had baseboard hot water heat. Pipe broke in slab so instead of jackhammering up the slab, homeowner wanted forced air for the...
  8. Replies
    10
    Views
    180

    Skin temp is in the 80s, not 98.6 so most of the...

    Skin temp is in the 80s, not 98.6 so most of the time, certainly when above 40, the air is noticeably warm. I've felt mine run at times and thought it was the gas backup but it wasn't. I have hybrid...
  9. For a good tech, probably look for a commercial...

    For a good tech, probably look for a commercial contractor. Must residential guys haven't seen a water cooled unit before, except a few who are versed in geos. But commercial guys see about...
  10. There are some 90s that work in MH but need to be...

    There are some 90s that work in MH but need to be sealed combustion. No 80% furnaces are like that unless it is a dedicated MH furnace.
  11. The 8000 Vision Pro WiFi says it does too.

    The 8000 Vision Pro WiFi says it does too.
  12. Ecobee comes to mind being both wifi and ODD...

    Ecobee comes to mind being both wifi and ODD capable. I have a Prestige IAQ which does it and more but requires the separate WiFi gateway. Some utilities give you rebates for smart stats. Our...
  13. Replies
    16
    Views
    255

    The air handlers being bigger do skew a little of...

    The air handlers being bigger do skew a little of the capacity more toward sensible but it isn't much. Real key is blower speeds. If they just leave it where it comes, that's 5 tons of air. I'd want...
  14. Replies
    14
    Views
    603

    Thank God you were a responsible business and not...

    Thank God you were a responsible business and not a moonlighter. Could you imagine side job Sam doing that with no insurance. Can you say bankrupt?
  15. Replies
    5
    Views
    186

    BK talks to the blower and no wire is on BK so...

    BK talks to the blower and no wire is on BK so going Ecobee would work just like you have now. The blower will function as it is.
  16. Replies
    23
    Views
    464

    Get a thermostat that has the feature on demand...

    Get a thermostat that has the feature on demand dehumidification. That will work with the air handler to slow the blower if the humidity is above the set point. Helps a little on humidity control and...
  17. I've seen them pulled out and hosed out. This...

    I've seen them pulled out and hosed out. This time no relatives, no friends. A trained pro!
  18. If you knew what furnace & coil is being proposed...

    If you knew what furnace & coil is being proposed along with the XR14, we could give you exact numbers.

    For example, outdoor unit, 4TXCB004 coil and S9V2B060 furnace, the 030 A/C gives 12.5 EER...
  19. Replies
    23
    Views
    464

    42% humidity in the house sounds excellent to me...

    42% humidity in the house sounds excellent to me for steamy Florida.
  20. Replies
    8
    Views
    165

    I find it as a York. Low static ducted air...

    I find it as a York. Low static ducted air handler. Probably put a high static duct system on it.
  21. Probably tweaked for a little higher EER. That's...

    Probably tweaked for a little higher EER. That's usually the case for a 2nd model in the same size.
  22. Replies
    2
    Views
    186

    It's an electric furnace for manufactured...

    It's an electric furnace for manufactured housing. Looks to me like you buy the evap coil separately from the furnace but should be able to get one meant for that unit. Looks like an ICP model #.
    ...
  23. Replies
    3
    Views
    145

    Check the SEER of anything you are quoted. Need...

    Check the SEER of anything you are quoted. Need to know furnace, A/C and coil model #s. They may call themselves a certain SEER, like XR17, but that doesn't mean you'll get it. I've never been that...
  24. Replies
    16
    Views
    537

    When the house is hot & humid, temp difference...

    When the house is hot & humid, temp difference will be low as the capacity of the equipment has skewed toward latent. That's why you see so much condensate coming out. As it gets the house dry, TD...
  25. Replies
    20
    Views
    836

    That's newer than the Dependable 92. The GUN. ...

    That's newer than the Dependable 92. The GUN.

    34, amazing job. Never seen a system static that low.
  26. You won't cool & dehumidify the joint with that...

    You won't cool & dehumidify the joint with that bath water. Most common leaving temperature from a chiller is around 44.
  27. Rather than put a smaller coil above the furnace,...

    Rather than put a smaller coil above the furnace, if I were that salesman I'd choose a C35-30/36C-2 for a perfect fit. The narrow coil WILL work but increases resistance to airflow vs the one above...
  28. Replies
    46
    Views
    808

    I'd sure trust quality and support of Mitsubishi...

    I'd sure trust quality and support of Mitsubishi over Midea any day.
  29. Replies
    22
    Views
    2,003

    TT ...

    TT

    https://www.tranetechnologies.com/en/index.html

    American Standard/Trane are under Trane technologies now.

    It's been this year I believe. Probably same as Carrier, concentrate on HVAC.
  30. Replies
    8
    Views
    261

    Locally about 2010 or so, our gas got steep and...

    Locally about 2010 or so, our gas got steep and we sold a lot of dual fuel. Now electricity has gone up and gas is reasonable so as people replace, they go straight cool outside. I've had dual fuel...
  31. Replies
    22
    Views
    2,003

    To be exact, Trane was spun off from IR and now...

    To be exact, Trane was spun off from IR and now is a company called Trane Technologies. Wasn't there a song about always changing corporation names?
  32. Replies
    9
    Views
    236

    Is there a particular model you have in mind?...

    Is there a particular model you have in mind? Usually I would say they weren't the most effective overall and can be restrictive. But that's in general. There may be units that are better.
  33. Replies
    2
    Views
    122

    That's fine. The return was increasing too,...

    That's fine. The return was increasing too, hotter hot means a bit less capacity on the system.
  34. That is correct. The example is the numbers I...

    That is correct. The example is the numbers I posted with the FV4 were lower than the numbers Joey posted with the FE4. It is a SYSTEM.

    Mfrs. will claim a model SEER if 1 match (in & out) of the...
  35. The numbers I gave for the Carrier was with the...

    The numbers I gave for the Carrier was with the FV4 air handler. Looks like the Carrier gets better numbers with the FE4. I think if I were doing it, I'd get the Greenspeed or if budget doesn't...
  36. Replies
    11
    Views
    241

    No biggie with POE and mineral oil in the same...

    No biggie with POE and mineral oil in the same system. You guy a replacement R22 comp for an older system and Copeland will have put POE in it.

    I sure wouldn't leave flush in a system. I wouldn't...
  37. I'd rule out clogged drier. Superheat pretty...

    I'd rule out clogged drier.

    Superheat pretty low.

    There is a limiit on DIY here so not sure how much we are going to be able to help you with.
  38. Actually, Joey, he'd be getting the RP16 as he...

    Actually, Joey, he'd be getting the RP16 as he has a heat pump system.

    The RP16 uses the proven 2 stage Copeland scroll. The 19 SEER is a 5 stage inverter rotary compressor. I still remember the...
  39. Model # of the unit being proposed? Rheem...

    Model # of the unit being proposed?

    Rheem Classic is below the level of the Infinity system so it should be considerably less. Rheem has the Prestige with the Econet control to compete with...
  40. Don't let him put cleaner in your coil. It will...

    Don't let him put cleaner in your coil. It will never come out. In the first days of 410, mfrs were worried about the existing mineral oil and the new POE oil having trouble together. That isn't the...
  41. About every brand of equipment these days has the...

    About every brand of equipment these days has the air handlers like that. So pick the best contractor and see what they suggest. Whether you get a TXV or piston depends upon brand.

    14 years even...
  42. Nothing I heard of here.

    Nothing I heard of here.
  43. Replies
    3
    Views
    196

    The Ecobee will do a heat pump just fine. If you...

    The Ecobee will do a heat pump just fine. If you can't figure out the wiring, might be wise to have a tech do it so nothing gets fried.
  44. That Carrier in the picture is at least 6 tons or...

    That Carrier in the picture is at least 6 tons or more. Won't find that in single phase.

    No, most if not all probably very limit the warranty on 3 phase equipment. Usually 5 compressor 1 parts....
  45. Replies
    10
    Views
    291

    Is the Friedrich a packaged unit? They don't make...

    Is the Friedrich a packaged unit? They don't make a standard split any more. On the Carrier - how was the 4 ton decided on? Bigger is certainly not better in Florida so guessing is not the way to...
  46. Replies
    11
    Views
    285

    We've sold both under sister brand names. Big...

    We've sold both under sister brand names. Big plus on Trane is quiet where some of the Rheem's can get rather noisy - fan noise. Less so with the 16 SEER. Also Rheem doesn't have pressure switches to...
  47. We sell a lot of Rheem modulating units, now with...

    We sell a lot of Rheem modulating units, now with their Econet control. Don't oversize which most contractors like to do. Long run cycles on low is so comfortable. In your car on a cold morning, do...
  48. Replies
    10
    Views
    358

    That heap comes from the 80s. Probably time to be...

    That heap comes from the 80s. Probably time to be putting that out to pasture while you're at it. 60% efficient on a good day and probably cracked heat exchanger.
  49. Replies
    5
    Views
    244

    Pretty rare for an HVAC contractor to do...

    Pretty rare for an HVAC contractor to do insulation but my senior boss did it back in the 70s & 80s. The equipment was gone by the time I got there in 1991. Or like Dean thought, maybe he partners...
  50. Replies
    6
    Views
    236

    https://thermastor.com/our-brands/santa-fe/

    https://thermastor.com/our-brands/santa-fe/