Search:

Type: Posts; User: rider77

Page 1 of 20 1 2 3 4

Search: Search took 0.08 seconds; generated 42 minute(s) ago.

  1. Replies
    5
    Views
    134

    Get a second opinion. It doesn’t sound like that...

    Get a second opinion. It doesn’t sound like that tech is interested in fixing anything.
  2. Replies
    7
    Views
    232

    Iíve never witnessed a PTAC that incorporates a...

    Iíve never witnessed a PTAC that incorporates a gas furnace.
    What kind of heat do you have now?
  3. Replies
    11
    Views
    273

    Likely oversized equipment, undersized duct, or a...

    Likely oversized equipment, undersized duct, or a combination of both.
    Your duct will have to be modified to accommodate 5 tons of airflow, or smaller equipment installed.
    How was 5 tons...
  4. Actually, the OPs description indicates a very...

    Actually, the OPs description indicates a very large possibility that the equipment is oversized even for daytime load.
    The sizing per square foot is extreme here, to say the least.
  5. Replies
    6
    Views
    257

    Sorry, but you posted on a site that doesn’t...

    Sorry, but you posted on a site that doesn’t allow DIY instruction. Per the bright red banner at the top of the page.
    I’d say just wait it out till tomorrow.
  6. Again, your unit is displaying every sign of...

    Again, your unit is displaying every sign of oversizing.
    Running the blower constantly will increase humidity more.
    You likely need smaller equipment.
  7. It sounds like an oversized units behavior.

    It sounds like an oversized units behavior.
  8. Replies
    5
    Views
    212

    I’ve heard of DIYers mentioning that brand, but...

    I’ve heard of DIYers mentioning that brand, but in 18 years I’ve never seen nor worked on one.
  9. Replies
    5
    Views
    212

    This is why itís ill advised to order your own...

    This is why itís ill advised to order your own equipment. Your left with a brand new system of unknown quality with no support and possibly no warranty.
    Iíd say your best bet right now is to bring...
  10. Thread: Control boards

    by rider77
    Replies
    13
    Views
    284

    You could have asked him to temporarily wire it...

    You could have asked him to temporarily wire it to allow for cooling operation, if possible.
    We are unable to instruct you how to do it yourself. Per the site rules.
  11. Thread: Control boards

    by rider77
    Replies
    13
    Views
    284

    Let him return with the part and do his thing....

    Let him return with the part and do his thing. Just make sure he tests the equipment before leaving.
  12. Thread: Control boards

    by rider77
    Replies
    13
    Views
    284

    What does your service technician suggest to fix...

    What does your service technician suggest to fix the problem?
  13. Replies
    5
    Views
    176

    Do not use those restrictive allergy filters. ...

    Do not use those restrictive allergy filters.
    The purpose of the filter is not to be a whole house air cleaner. It’s to prevent dirt build up in the equipment.
  14. Replies
    11
    Views
    228

    I would not operate it like that. Without a...

    I would not operate it like that. Without a professional looking things over and giving the ok.
  15. Manual J takes that into account. Sizing isn’t an...

    Manual J takes that into account. Sizing isn’t an estimation or opinion. It’s a detailed calculation.
  16. Replies
    5
    Views
    253

    Brand doesn’t much matter- ...

    Brand doesn’t much matter-

    https://www.angieslist.com/articles/difference-between-best-hvac-brands.htm

    It is of high importance that the unit is sized correctly-
    ...
  17. Replies
    11
    Views
    228

    Could cause backdraft issues for other fuel...

    Could cause backdraft issues for other fuel burning appliances in the area. Could cause freeze ups if the blower is downstream of the coil.
  18. Sizing isn’t done via square footage. Basements...

    Sizing isn’t done via square footage.
    Basements often only need dehumidification and a small amount of heat. And shouldn’t be on the main hvac system.
  19. You have 3.5 tons for a 2,000 square foot well...

    You have 3.5 tons for a 2,000 square foot well insulated house in Canada?
    I’d say you have oversized equipment.
  20. Thread: What to buy?

    by rider77
    Replies
    5
    Views
    196

    There is no such thing as a best brand. The...

    There is no such thing as a best brand.
    The installer means the most when it comes to the outcome.
    Please remove your pricing. It’s against site rules.
  21. There is a contractor locator map here on the...

    There is a contractor locator map here on the site that includes the volunteers here.
    Maybe see if someone is in your area that can help.
  22. Please note the bright red banner at the top of...

    Please note the bright red banner at the top of the page. We cannot assist in DIY instruction here.
  23. Replies
    4
    Views
    200

    Should come on with the outdoor fan.

    Should come on with the outdoor fan.
  24. Dave was this a furnace you bought and installed...

    Dave was this a furnace you bought and installed yourself?
  25. What does the installing company/technician have...

    What does the installing company/technician have to say about the problem?
  26. Replies
    5
    Views
    253

    Could be old ceiling radiant electric heaters.

    Could be old ceiling radiant electric heaters.
  27. No, this would not help the problem your...

    No, this would not help the problem your experiencing.
  28. Replies
    7
    Views
    230

    What motor is your service technician suggesting?

    What motor is your service technician suggesting?
  29. Replies
    15
    Views
    331

    The sticker on the unit that most miss says “up...

    The sticker on the unit that most miss says “up to” before giving a seer number.
    The AHRI match number will show the true efficiency and capacity ratings.
    Mismatched equipment true efficiency and...
  30. If I remember correctly R-407C has a capacity...

    If I remember correctly R-407C has a capacity loss when compared to R22.
  31. Replies
    14
    Views
    315

    You’ll likely going to have to hire an...

    You’ll likely going to have to hire an engineering service to do them.
    What’s your current static and CFM?
  32. Replies
    14
    Views
    315

    There is no such rule of thumb

    There is no such rule of thumb
  33. Replies
    14
    Views
    315

    You don’t have anywhere near enough duct for your...

    You don’t have anywhere near enough duct for your proposed new unit.
    In fact, you don’t have enough duct for your existing unit. Which may be causing your poor performance.
    Do not, under any...
  34. Replies
    15
    Views
    471

    Sounds like a sizing and possible duct issue. ...

    Sounds like a sizing and possible duct issue.
    Ideally you should never “feel” the air flowing around the house while the systems running.
  35. Replies
    7
    Views
    232

    Do you have a packaged unit or split system? Is...

    Do you have a packaged unit or split system?
    Is it located in the attic or on the roof?
  36. Replies
    3
    Views
    243

    The cheap no name units sold on the internet are...

    The cheap no name units sold on the internet are usually just cheap disposable knockoffs that may last a couple years and need replacement. Their performance reflects on the price paid-cheap.
  37. Replies
    15
    Views
    471

    Hire the installer. Not the brand. The hands...

    Hire the installer. Not the brand.
    The hands working on the equipment, means a lot more then brand name.
    Brand means almost nothing.
  38. Running the fan all the time can increase indoor...

    Running the fan all the time can increase indoor humidity.
  39. Replies
    12
    Views
    279

    That’s a 3.5 ton unit. Capacitors aren’t sized...

    That’s a 3.5 ton unit.
    Capacitors aren’t sized via tonnage. Compressors and motors are specific to what their capacitor requirements are.
    A compressor tonnage difference with the outdoor unit...
  40. Replies
    6
    Views
    423

    Goodway has several options that would probably...

    Goodway has several options that would probably work. Some will require a separate water supply.
  41. Not wise to assume it was sized correctly. Most...

    Not wise to assume it was sized correctly. Most are not.
    How often does the unit run in a very hot day?
  42. Replies
    5
    Views
    211

    Sorry, but we can’t offer DIY instruction here. ...

    Sorry, but we can’t offer DIY instruction here.
    Not wise to try repairs without the proper tools.
  43. Replies
    5
    Views
    211

    Don’t think you have the right amount in? Are...

    Don’t think you have the right amount in?
    Are you not using a scale?
  44. Replies
    6
    Views
    356

    There is no logical answer to a question of best...

    There is no logical answer to a question of best brand. Please read here for further explanation-

    https://www.angieslist.com/articles/difference-between-best-hvac-brands.htm

    The more important...
  45. Replies
    2
    Views
    149

    Seems it’s likely time for a service call. The...

    Seems it’s likely time for a service call. The site rules, highlighted in red at the top of the page, prevent us from giving DIY instruction.
    It’s likely costing you excessive energy turning the...
  46. Replies
    4
    Views
    182

    Honeywell Redlink is nice. You’ll have to...

    Honeywell Redlink is nice.
    You’ll have to consult your contractor for how to go about wiring and controlling everything. This site doesn’t allow diy instruction.
    What you want to do is possible.
  47. Replies
    4
    Views
    182

    Nest is likely the absolute worst possible choice...

    Nest is likely the absolute worst possible choice one could make for a thermostat.
    It’s unfortunate that they set up booths in big box stores to get consumers to drink their Kool-Aide.
    And their...
  48. Replies
    6
    Views
    317

    How many returns run to this unit, and what...

    How many returns run to this unit, and what sizes/materials are they?
    How close is this noisy return to the air handler?
    What tonnage is the unit?
  49. Replies
    10
    Views
    293

    Just a warning, but if you buy your own off the...

    Just a warning, but if you buy your own off the internet you’ll probably get no warranty. And if you do, you’ll be the card holder. Which means you’ll be the one putting up the money to the...
  50. Incorrect refrigerant charge, metering device...

    Incorrect refrigerant charge, metering device problem, poor airflow, incorrect refrigerant piping, the list goes on.
Results 1 to 50 of 981