Search:

Type: Posts; User: ChuckDe

Page 1 of 2 1 2

Search: Search took 0.02 seconds.

  1. You’re welcome. Google helps again. Sent...

    You’re welcome. Google helps again.


    Sent from my iPhone using Tapatalk
  2. https://www.fieldpiece.com/videos/video/spk2-and-s...

    https://www.fieldpiece.com/videos/video/spk2-and-spk3-thermometers

    This video may help.


    Sent from my iPhone using Tapatalk
  3. Thread: tin snips

    by ChuckDe
    Replies
    6
    Views
    455

    If you scroll down on the Amazon page you can buy...

    If you scroll down on the Amazon page you can buy all three together with just a few mouse clicks.


    Sent from my iPhone using Tapatalk
  4. Thread: tin snips

    by ChuckDe
    Replies
    6
    Views
    455

    Malco M2003 MAX2000 1-3/8-Inch Cut Capacity...

    Malco M2003 MAX2000 1-3/8-Inch Cut Capacity 6-Inch Handle Straight, Left, and Right Cut Aviation Combo Cut Snip https://www.amazon.com/dp/B00004SUQL/ref=cm_sw_r_cp_api_i_1S4LDb653EZXP

    The...
  5. Replies
    31
    Views
    2,074

    https://youtu.be/ITxlwN3xEDk Job Link Firmware...

    https://youtu.be/ITxlwN3xEDk

    Job Link Firmware Update video has been updated.


    Sent from my iPhone using Tapatalk
  6. Replies
    31
    Views
    2,074

    https://youtu.be/FMi7Ir2Z4vI Great video from...

    https://youtu.be/FMi7Ir2Z4vI

    Great video from Fieldpiece on YouTube.


    Sent from my iPhone using Tapatalk
  7. Replies
    31
    Views
    2,074

    With the 2.4.1 app version after the probe...

    With the 2.4.1 app version after the probe updates the app would continue to suggest probes could be updated. Now with 2.4.2 the app is no longer suggesting upgrade of recently upgraded probes.
    ...
  8. Replies
    12
    Views
    791

    If you haven’t already, firmware updates are...

    If you haven’t already, firmware updates are available for the probes. The updates will allowed the probes (with the Fieldpiece app) to perform data logging. This feature may prove to be a valuable...
  9. Replies
    12
    Views
    791

    https://www.trutechtools.com/AVT45 Sent from...

    https://www.trutechtools.com/AVT45


    Sent from my iPhone using Tapatalk
  10. Replies
    5
    Views
    399

    https://www.acservicetech.com/ is another great...

    https://www.acservicetech.com/ is another great source.




    Sent from my iPhone using Tapatalk
  11. Replies
    5
    Views
    399

    https://www.hvacrschool.com HVACRSCHOOL.COM is...

    https://www.hvacrschool.com

    HVACRSCHOOL.COM is my favorite.


    Sent from my iPhone using Tapatalk
  12. Replies
    2
    Views
    344

    Staic air pressure

    There are lots of great YouTube videos on static, but one of my most recent favorite pieces on static is a podcast by Bryan Orr. If you can navigate to HVAC School podcasts, look for Short # 59 - Low...
  13. Replies
    46
    Views
    6,059

    I’d say the apps are overkill for your...

    I’d say the apps are overkill for your application. But hey, the apps are free.


    Sent from my iPhone using Tapatalk
  14. Replies
    46
    Views
    6,059

    Dave, Have you selected the green Probe Manager...

    Dave, Have you selected the green Probe Manager button and then the Reset Mappings button?
  15. Replies
    46
    Views
    6,059

    One post up there is a link to Jim Bergmann ‘s...

    One post up there is a link to Jim Bergmann ‘s profile. In the profile is his email address.
  16. Thread: True tech tool

    by ChuckDe
    Replies
    5
    Views
    857

    TTT is moving to bigger warehouse and will...

    TTT is moving to bigger warehouse and will suspend shipping for a few days, starting 21 Feb. I just received an email from then few hours ago.


    Sent from my iPhone using Tapatalk
  17. Thread: True tech tool

    by ChuckDe
    Replies
    5
    Views
    857

    Getschooled is the HVAC School for 8%.. The...

    Getschooled is the HVAC School for 8%.. The school provides Lots of great free training,,, many formats.


    Sent from my iPhone using Tapatalk
  18. Replies
    47
    Views
    2,798

    https://uploads.tapatalk-cdn.com/20181101/0a3ff5e7...

    https://uploads.tapatalk-cdn.com/20181101/0a3ff5e72cf93d1f062eedfa2bf3bfd7.jpg

    Don’t know if it has an impact on this particular problem, but the Victor chart shows 3 to 5 PSIG recommendation for...
  19. Replies
    47
    Views
    2,798

    https://www.thefabricator.com/article/safety/fuel-...

    https://www.thefabricator.com/article/safety/fuel-your-safety-knowledge

    As the linked info suggests you may have a defective regulator. A larger cylinder is the long term fix (after regulator is...
  20. Replies
    11
    Views
    957

    Socket Organization

    https://uploads.tapatalk-cdn.com/20180928/8dd3587159d1bf8d701496e4c7efb41e.jpg
    Sockets like this?

    Google socket rack. Seems everyone sells something like this.


    Sent from my iPhone using...
  21. My favorite is the Fieldpiece kit coupled with...

    My favorite is the Fieldpiece kit coupled with MeasureQuick app. MQ’s support for Fieldpiece probes is a recent addition, like icing on the cake. Fieldpiece’s app exhibited intermittent connectivity...
  22. Replies
    25
    Views
    1,714

    It’s important to not have any adapters between...

    It’s important to not have any adapters between the clamp and meter. That not being an issue, you are probably correct about it being a meter issue.


    Sent from my iPhone using Tapatalk
  23. Replies
    46
    Views
    6,059

    Measurequick and Fieldpiece

    Wow, nice!

    Thanks Jim! Bobby!

    I’m looking forward to trying it soon.


    Sent from my iPhone using Tapatalk
  24. Replies
    22
    Views
    1,556

    Pressures being equal, gravity still rules. If...

    Pressures being equal, gravity still rules.

    If pressure in recovery machine, pressure in hose, and pressure in recovery cylinder all equal 88 psig, and if there is liquid in the hose,,,, then...
  25. Replies
    22
    Views
    1,556

    Hopefully OP understands that a “full cylinder”...

    Hopefully OP understands that a “full cylinder” is based on its weight, not on internal pressure. 38 to 41.9 Lbs is full (80% of 30 Lbs = 24 Lbs ; 24 + 17.9 = 41.9 Lbs)


    Sent from my iPhone...
  26. Replies
    22
    Views
    1,556

    As David says, the saturated pressure of R134a,...

    As David says, the saturated pressure of R134a, at 98 F is 120 PSI. So even when your recovery cylinder is full, about 38 to 41 Lbs, the pressure inside will still be about 120 PSI (depending on the...
  27. Replies
    4
    Views
    797

    https://www.trutechtools.com/HowtoReturnMerchandis...

    https://www.trutechtools.com/HowtoReturnMerchandise




    Sent from my iPhone using Tapatalk
  28. Replies
    4
    Views
    909

    You may want to email to info@measurequick.com ...

    You may want to email to info@measurequick.com

    Whenever I’ve emailed, Bobby or Jim have replied promptly, friendly, and professionally. And most importantly I’ve seen prompt app update fixes for...
  29. Replies
    8
    Views
    1,536

    Anywhere near that much water would have made it...

    Anywhere near that much water would have made it rough on an oil type pump!
  30. Replies
    8
    Views
    1,536

    The Jug Lugger?

    The Jug Lugger?
  31. Replies
    8
    Views
    1,536

    Oil-less vacuum pump

    https://www.youtube.com/watch?v=A_ar8ysARR4

    An oil-less vacuum pump is presented in this YouTube video. I wonder if anyone in the mechanical industry has any experience or interest in something...
  32. John, Another tool you may wanna try is the...

    John, Another tool you may wanna try is the MeasureQuick app.. If you manually plug your numbers into the app you can look at the “Diagnostic” suggests the app offers. Not surprising, the app...
  33. John, All the info hvacskills and David...

    John, All the info hvacskills and David suggested would be helpful..

    I’ll add, don’t forget the air side. Is your system moving 5 tons of air? (1750 - 2000 CFM). An installer who would braze...
  34. Replies
    9
    Views
    1,290

    When the reversing valve coil draws excessive...

    When the reversing valve coil draws excessive current, is the voltage across the coil still 24 V? Or is there possibly a poor connection causing voltage across the coil to drop?


    Sent from my...
  35. Replies
    9
    Views
    1,290

    Is the ferrous metal core in the center of the...

    Is the ferrous metal core in the center of the coil (pilot portion of the valve) moving when 24 V is applied (pulled into the coil)? Core stuck maybe?

    I’m still trying to find the YouTube video...
  36. How to disable defrost completely in a Carrier Infinity Heat Pump

    Don’t make it complicated.. All defrost does is controls the fan and the reverse valve,,, so, “hot wire” them. Short across the fan relay on the defrost board so the fan gets power whenever the...
  37. Replies
    26
    Views
    1,353

    The blower performance and amp draw you describe...

    The blower performance and amp draw you describe is true for the “squirrel cage” (indoor) blower. I believe that the amp draw and airflow performance for outdoor (propeller type) blades follows a...
  38. Replies
    26
    Views
    1,353

    Maybe an intake that’s fine for a 800 CFM...

    Maybe an intake that’s fine for a 800 CFM motor/blade combo is restricted for a 1600 CFM combo?


    Sent from my iPhone using Tapatalk
  39. Replies
    26
    Views
    1,353

    cfm blowing out the side

    Could it then be that the motor is rated for greater RPM than the fan blade(s) are designed for (thus causing an outward angle flow)?

    Added: Or the fan blade has been mistakenly replaced with an...
  40. Replies
    26
    Views
    1,353

    Motor running in reverse? Many replacement...

    Motor running in reverse? Many replacement motors can run CW or CCW depending on how they are wired.


    Sent from my iPhone using Tapatalk
  41. Thread: i Manifold

    by ChuckDe
    Replies
    191
    Views
    18,334

    For anyone who would like to see it, the...

    For anyone who would like to see it, the recording of that session is now available on YouTube.

    https://youtu.be/yN6c4_uuFnU




    Sent from my iPhone using Tapatalk
  42. Replies
    33
    Views
    8,588

    This may not be directly related to your problem,...

    This may not be directly related to your problem, but to keep things safe, have you checked to be sure the chassis (coil case) is properly grounded?
  43. Replies
    21
    Views
    2,121

    Yellow is 4 Violet is 7 Red is 2 (multiplier,...

    Yellow is 4
    Violet is 7
    Red is 2 (multiplier, so 00)

    Gold is 5% tolerance

    So, 4700 Ohms
  44. Replies
    75
    Views
    6,170

    Amp clamps

    http://en-us.fluke.com/training/training-library/test-tools/clamp-meters/clamp-meter-fundamentals.html

    You may be surprised how forgiving these Amp clamps are.
  45. Replies
    75
    Views
    6,170

    No readable markings of required cap value on the...

    No readable markings of required cap value on the associated motor/herm ID plates?
  46. Replies
    48
    Views
    5,812

    Is the evaporator in what should be conditioned...

    Is the evaporator in what should be conditioned space (above drop ceiling I understand)?
  47. Replies
    48
    Views
    5,812

    What is your superheat? If low, it might...

    What is your superheat? If low, it might indicate overcharge or insufficient airflow,,,, which would leave too much cooling centered right there at the evaporator,,,, possibly causing the excessive...
  48. Replies
    48
    Views
    5,812

    Is there a chance that high humidity outdoor air...

    Is there a chance that high humidity outdoor air is entering the conditioned space, or into the return ducting?

    How much insulation is covering the ducting,,,, and insulation above the drop...
  49. Replies
    48
    Views
    5,812

    In the opening post you mention a .47 inch WC...

    In the opening post you mention a .47 inch WC drop across the coil, this implies the coil is nearly blocked (no airflow) or, water plugging the manometer probe?
  50. Replies
    48
    Views
    5,812

    PHM's suggestion to clean the coil is an...

    PHM's suggestion to clean the coil is an excellent one. Believe I've heard before that this cleaning of a new coil helps the water to "stick" to the coil,,,, and not fly where you don't want it.
Results 1 to 50 of 78