  1. Replies
    4
    Views
    350

    If you can get the file to display on your screen...

    If you can get the file to display on your screen on a computer, you can do this with the prtscr key. Paste into paint, resize to the pixels you want, save as png. Copy that png file to your station...
  2. Replies
    7
    Views
    452

    From my memory, the pneumatic controls were pipe...

    From my memory, the pneumatic controls were pipe fitter's work. As things transitioned, the Pipe fitters retained the HVAC controls as their work. Somewhere along the line a compromise was reached...
  3. Replies
    49
    Views
    8,016

    This thread is 2years old. He either fixed the...

    This thread is 2years old. He either fixed the problem by now, or is not working on it anymore...
  4. Replies
    35
    Views
    2,058

    It is important for the installer to know the...

    It is important for the installer to know the equipment they are connecting to the RS485 Bus. Different manufacturers implement the standard in different ways. + and - should be isolated from chassis...
  5. Replies
    1
    Views
    351

    Dead JCI FX60E Trash?

    I have a dead JCI FX60E in my hand. It fails out of the initial boot on the serial shell. Tests at this level all end with "Try Again". Never even gets to the menu where you set passwords, FTP and...
  6. http://cgproducts.johnsoncontrols.com ...

    http://cgproducts.johnsoncontrols.com

    http://cgproducts.johnsoncontrols.com/content.aspx?CID=214#
  7. There should be 1 more setpoint not in the list...

    There should be 1 more setpoint not in the list you show. The Effective setpoints are never writeable. The six software setpoints you displayed are part of a zone setpoint block that sets up the...
  8. One solution would be to modify the program in...

    One solution would be to modify the program in the VMA to bring the required setpoints to the network input points. You would need the CCT program to do this. Only 12 units would not take too long.
  9. Replies
    15
    Views
    779

    There are calibration values that you can modify...

    There are calibration values that you can modify that change the hardware. Or it may be calibrated in the program by adjusting the ends of the 0 to 10 VDC conversion to % in the software. Either...
  10. So far there is not enough information to answer...

    So far there is not enough information to answer this question. First where are you?. Design heating temperatures vary greatly with location. What is the "heating coil"? AHU, VAVRH, FCU, RAD...? What...
  11. Replies
    13
    Views
    770

    At one point I think I saw a JCI N2 VMA style...

    At one point I think I saw a JCI N2 VMA style controller mounted on a valve at some show or something. I don't think the product ever came to be though. I think they were testing the market.

    But,...
  12. Replies
    12
    Views
    809

    By "it" I assume you are asking how data is...

    By "it" I assume you are asking how data is shared between the BACnet devices. Both the MSEA and FX product can share data peer to peer or by the supervisor. How the product does it is dependant on...
  13. Replies
    12
    Views
    809

    Under tools you will find where you can upload...

    Under tools you will find where you can upload the programs from multiple controllers to the laptop. You will then need to open each file to find the peer to peer sharing. This is done linking...
  14. Ok, with the added info you should need something...

    Ok, with the added info you should need something similar to the middle picture of the tekmar 2 page sheet. Just take out the boiler and add the electric for the tank. You and your supplier should be...
  15. FYI ...

    FYI

    http://www.tekmarcontrols.com/images/_literature/a0002_m_07.pdf?lbisphpreq=1

    http://www.tekmarcontrols.com/images/_literature/p9336_02.pdf?lbisphpreq=1

    I have nothing to do with Tekmar,...
  16. Your distributor should set you up. Your could...

    Your distributor should set you up. Your could look at the TEKMAR controllers for you education. I like zone valves in our commercial work, but this floor stuff really works better with pumps on each...
  17. Replies
    4
    Views
    466

    What type of valve are the old valves? Globe or...

    What type of valve are the old valves? Globe or ball or something else? What is the pipe size of the old valve? 3 way or 2 way? Brand of the valve? Age?

    If you can give some of this information...
  18. Replies
    55
    Views
    1,605

    You may need to edit the state table. Or delete...

    You may need to edit the state table. Or delete the state table connection if not needed. You should probably disable the auto tuning if you don't have something controlling when the process runs....
  19. I know it used to work without any license on the...

    I know it used to work without any license on the PC. I had the JCI LX version of the plugins running on the browser connection to a JACE. I installed Workbench on the PC. Workbench would not run...
  20. Replies
    55
    Views
    1,605

    I think the side loop button will do what you are...

    I think the side loop button will do what you are looking for. Create a custom and then add a side loop will get you started.

    I suggest this for both your application and as a self training path....
  21. Replies
    3
    Views
    459

    Here you go. New Custom Application OK Right...

    Here you go.
    New
    Custom Application
    OK
    Right click to add 2 inputs.
    Right click to add 1 output.
    Save.
    Done.

    Not that I think this is what you are thinking of, but meets the spec...
  22. Replies
    11
    Views
    584

    Another option is evaluate valve position to...

    Another option is evaluate valve position to reset the plant DP setpoint. Make provisions so network trouble failsafes the DP to an acceptable level (maybe the last level).
  23. Replies
    12
    Views
    1,223

    Any chance "someone" is putting something else in...

    Any chance "someone" is putting something else in the plug? Trying to stuff a rj45 or usb or a pencil in there? Shorts or broken/bent pins would do this.
  24. Depending on your ultimate goal, I would suggest...

    Depending on your ultimate goal, I would suggest working around the Metasys and trying the niagara on the LON trunk or maybe a LON/IP router.

    Though the BACnet thing suggested above may work. I...
  25. Yep, when they bleed red blood they are dead. ...

    Yep, when they bleed red blood they are dead.

    We used a JCI actuator on these valves, VA-4233 and a V-9999-BC1 adaptor. But now we mostly replace the whole valve. Packing and seats getting pretty...
  26. Replies
    9
    Views
    675

    So what does "no luck in 2 days" mean? If you...

    So what does "no luck in 2 days" mean? If you worked on this for 2 days, I hope you have some more information...

    Ping?
    Open ports?
    Network Scanner?
    Login?
    Java?
    Serial Shell?
    Lights?...
  27. Replies
    5
    Views
    674

    On a related note... Are you sure you want to...

    On a related note...
    Are you sure you want to map points in the NAE?

    If this is a BACnet field controller on the Field bus you may want to map directly to the field controller on the JACE. This...
  28. Replies
    9
    Views
    932

    I think Verasys is the route you should go. I...

    I think Verasys is the route you should go. I have used the PCT zoning system. Works fine, but I had to customize both times I used it due to my equipment not the same as the programmer designed....
  29. There is a setting in the platform for how often...

    There is a setting in the platform for how often to save the station automatically. But, it is good practice to save it manually after making changes like writing a new program. Also it is good to...
  30. Replies
    53
    Views
    3,219

    Planes and Boats have had "autopilots" for years....

    Planes and Boats have had "autopilots" for years. In the air or on the water the lanes are much wider. I can easily walk from one goal post to the opposing goal post on an empty football field. Much...
  31. I think the Passcode is disabled by default. I...

    I think the Passcode is disabled by default. I think it prompts for a code when you enable it.

    There is a BACnet point where you can see the code from the network. Changes are made at the display.
  32. You got it. I am far enough north that heating...

    You got it. I am far enough north that heating valves are normally open without any air and dampers are closed to OA without any air. If we install anything else something will freeze someday. Almost...
  33. Typically a Classroom UV will have an EP valve...

    Typically a Classroom UV will have an EP valve that dumps the air off the Damper only on a steam unit when the fan stops. Hot water units usually dump both the damper and the valve. Most steam UV...
  34. You will need to buy the PCT software. It should...

    You will need to buy the PCT software. It should not be too hard to find a distributor to sell it to you. Look for JCI ABCS distributor.

    The JCI FX JACE is an open device license so any brand...
  35. Replies
    7
    Views
    868

    Quick tip. HVACPRO can get Controller information...

    Quick tip. HVACPRO can get Controller information for the whole bus. Select Controller information and select multiple controllers. This will give you a notepad file of configuration type, address...
  36. This is the correct answer. But the S2 N2 to...

    This is the correct answer. But the S2 N2 to Bacnet Router would work too. Just turn on the BACnet portion of the NAE and you should be able to map the NAE points on a JACE on the same ethernet...
  37. Replies
    12
    Views
    2,154

    2015 thread hijacked today??? really???

    2015 thread hijacked today??? really???
  38. Replies
    4
    Views
    547

    I am guessing you have a series of data in a...

    I am guessing you have a series of data in a chart and want to make a conversion in the controller. If a linear approximation is not accurate enough you may need to determine a representative...
  39. I know the issue is solved, but for a little more...

    I know the issue is solved, but for a little more clarity (I hope)...

    After you discover the points, before you add them you should add the "relinquish default" not the "present value" for the...
  40. Replies
    3
    Views
    1,018

    I have done this a few times. My goal is usually...

    I have done this a few times. My goal is usually to make the NAE portion not really a part of the system anymore as the JCI Branch controls this product as a proprietary product.

    Method 1:...
  41. Replies
    5
    Views
    574

    How about a PENN S66 Series Electronic Fan...

    How about a
    PENN S66 Series Electronic Fan Speed Control
    or a
    Hoffman 700 series
  42. My guess is duplicate Device IDs. BACnet can not...

    My guess is duplicate Device IDs. BACnet can not have any duplicate device Id on any trunk. MSEA (JCI NAE and ADS) does not use device IDs so duplicates do not cause a problem until a BACnet...
  43. Replies
    6
    Views
    793

    I am not sure and I don't work with NAE to Lon,...

    I am not sure and I don't work with NAE to Lon, but I dont think the NAE configures the LON network. I think JCI has a tool to do that. MCL Tool is the product I think.
  44. Replies
    18
    Views
    1,965

    JCI M-Tool GX-9100 program tool. Plug into DX...

    JCI M-Tool GX-9100 program tool. Plug into DX 9100, upload DX, Fix problem, Download DX and XT.
  45. Replies
    10
    Views
    2,258

    I thought it was OK. Just had to do the demo or...

    I thought it was OK. Just had to do the demo or practice before the test part so you knew how they wanted me to do it.
  46. Check that in my last post... Easiest solution...

    Check that in my last post...

    Easiest solution is to just hook it up and ignore the "problem". See if anyone notices...

    Not an advocate of crappy work like that, but it is an easier "solution"....
  47. This raised my curiosity... Graphed the data...

    This raised my curiosity...
    Graphed the data from ACI in Excel...
    Compared the ohms of Type 2 vs 3 close to linear...
    Roughly built a table of the Deg F temp of the incorrect readings you would...
  48. It is not too bad as long as the ports get...

    It is not too bad as long as the ports get through the Firewall. The tool I suggest is the 3#. IT dept. won't be much help with this one though, They can't reach the firewall from their cubicle, much...
  49. Replies
    1
    Views
    634

    Program service and a Query similar to this..

    Program service and a Query similar to this..
  50. Replies
    10
    Views
    2,508

    I ran into those limits last year when I replace...

    I ran into those limits last year when I replace a DX9100 and added a bunch of new points. PCG2611 had Faults over address 12. I just exposed the points where they connected in the PCT configuration...