  1. Replies
    11
    Views
    285

    Been using the Blue Patriot 450 since it came...

    Been using the Blue Patriot 450 since it came out. Nobody says they can't hear me, and it's been holding up. Has a good range so I can put the phone down somewhere what has a signal and crawl in a...
  2. Replies
    26
    Views
    1,027

    You an engineer or account before you took up...

    You an engineer or account before you took up HVAC? Lol
  3. Replies
    40
    Views
    1,107

    Ummmm... Who took the screw out 20 miles away...

    Ummmm...
    Who took the screw out 20 miles away from the service station?
    Maybe the old guy was pissy about that :)
  4. Replies
    37
    Views
    4,385

    Is it too late to make this a poll? Seems heavy...

    Is it too late to make this a poll?
    Seems heavy towards measure quick.
  5. Replies
    39
    Views
    1,532

    I might break out the 45% on brass to steal 😇

    I might break out the 45% on brass to steal 😇
  6. Replies
    39
    Views
    1,532

    I could say the same about using 15% 👍

    I could say the same about using 15% 👍
  7. Replies
    8
    Views
    5,133

    I give two age ranges. If the tag says TX it's...

    I give two age ranges.
    If the tag says TX it's old.
    If the tag says NY it's really old :)
  8. Replies
    8
    Views
    5,133

    Doesn't compute for older equipment

    Doesn't compute for older equipment
  9. Replies
    8
    Views
    2,460

    Pin 3 and 6 make the power switch button counting...

    Pin 3 and 6 make the power switch button counting from the left looking at the board with the touch pad ribbion cable removed.
  10. Replies
    28
    Views
    798

    You were missing coil temp and or evap outlet...

    You were missing coil temp and or evap outlet temp in the diagnosis. There is a PDF with the cut in and cut out temps since you have the part numbers. It may be going cold on the cut out. With it...
  11. Replies
    28
    Views
    798

    It's 5 ozs. Just charge it lol

    It's 5 ozs. Just charge it lol
  12. Replies
    28
    Views
    798

    Check the evap drain pan for leaks if you plan on...

    Check the evap drain pan for leaks if you plan on selling it. Haven't seen one running a mechanical stat. All I see of those are electronic air stat with coil temp termination for defrost.
  13. Replies
    16
    Views
    740

    Had a pressure gauge that was way off before too....

    Had a pressure gauge that was way off before too. Over inflated
  14. Replies
    39
    Views
    1,532

    Yes sounds like the wrong flux

    Yes sounds like the wrong flux
  15. Replies
    11
    Views
    563

    At least it would be for me.

    At least it would be for me.
  16. Replies
    11
    Views
    563

    I think it was more for vacuum rig testing not...

    I think it was more for vacuum rig testing not system testing.
  17. Replies
    16
    Views
    740

    Check the pressure in the front. They might have...

    Check the pressure in the front. They might have cranked them up when they did the back.
  18. Replies
    30
    Views
    750

    Your right! Cheap and afraid lol

    Your right!
    Cheap and afraid lol
  19. Replies
    30
    Views
    750

    Here's a brand new one got both lol810971

    Here's a brand new one got both lol810971
  20. Replies
    30
    Views
    750

    PU55IES use those caps :)

    PU55IES use those caps :)
  21. Replies
    30
    Views
    750

    Most are brazed shut

    Most are brazed shut
  22. Replies
    30
    Views
    750

    Used to be more common. The ultrasonic welded...

    Used to be more common. The ultrasonic welded ones were almost a guaranteed leak not so much anymore. Lokring caps used to be leakers been ok lately. The spot where they crimp is a weak point too....
  23. Replies
    8
    Views
    336

    High head pressure puts it in a standby. Seen low...

    High head pressure puts it in a standby. Seen low voltage trip the same.
  24. Replies
    12
    Views
    619

    Yes you should do more testing if you want to...

    Yes you should do more testing if you want to learn about it. Calibration means nothing in regards to this kind of clamp error.

    This was a liquid line in a 35 cooler. Not in the air stream or it...
  25. Replies
    212
    Views
    9,872

    I sold my SRL8 to a school otherwise I'd retest...

    I sold my SRL8 to a school otherwise I'd retest it. For the gasses I was dealing with most at the time like 22, 134 and 404 the SRL8 didn't cut it.
  26. Replies
    79
    Views
    21,223

    Fieldpiece also doesn't tell you what those some...

    Fieldpiece also doesn't tell you what those some gasses their detectors detect better than others are so it must be better for sales to keep it a secret.
  27. Replies
    79
    Views
    21,223

    This has been discussed at nauseam over the years...

    This has been discussed at nauseam over the years but this specific topic with the SRL2 has been dead for years. It went from the SRL2 being the best detector to it does better with some gas than...
  28. The freeze times for his machine were in the pic

    The freeze times for his machine were in the pic
  29. After a full and proper freeze with ⅛ bridge...

    After a full and proper freeze with ⅛ bridge harvest starts and count to 45 and the ice will drop. They cut harvest in half with the little air pump that breaks the vacuum behind the sheet.
  30. Always been sticking hot gas valves on these...

    Always been sticking hot gas valves on these intermittent ones for me. Haven't had a weird board relay on these. Those danfoss valves like to stick for some reason.
  31. The E20 code Probably dirty water level...

    The E20 code

    Probably dirty water level sensor. Separate issue.810920
  32. PHM the new ones are fast and can also harvest in...

    PHM the new ones are fast and can also harvest in 45 sec. if everything is humming along.
    810918
  33. Sounds like it did whatever it has been doing to...

    Sounds like it did whatever it has been doing to freeze up but you weren't prepared to test what the issue was with the harvest cycle.
  34. Was there ice and did it drop?

    Was there ice and did it drop?
  35. Sorry are you saying the ice didn't drop after 5...

    Sorry are you saying the ice didn't drop after 5 mins but did after a double batch of ice?
  36. Also at 7 mins you might be set too thin of...

    Also at 7 mins you might be set too thin of bridge.

    If the water tray is full low and high are yes. One common rod that makes to the low and high. The low rod is about the same length as the...
  37. Looks like a dirty water level probe with that...

    Looks like a dirty water level probe with that water fault. Sometimes I ohm them to ground and they show Mohm to ground. Even when they don't look dirty they are.
  38. Replies
    79
    Views
    21,223

    That's more than a few. Do you leave them on...

    That's more than a few. Do you leave them on different sites where you work?

    My first ZX was ok until I needed a replacement sensor. Had a good run of multiple sensors that weren't any good and...
  39. Replies
    79
    Views
    21,223

    No different

    No different
  40. Replies
    79
    Views
    21,223

    Well?

    Well?
  41. Replies
    79
    Views
    21,223

    Wrong

    Wrong
  42. We?? maybe Fieldpiece is over their skis

    We?? maybe Fieldpiece is over their skis
  43. Replies
    6
    Views
    329

    I've extended my thermistor sensor with a 100...

    I've extended my thermistor sensor with a 100 foot extension cord before. My cord reads 3 tenths of a ohm for 100 ft.

    The difference between 39 and 40 on a Copper 4011 is 732 ohms

    If you are...
  44. Replies
    6
    Views
    329

    I never signed up. I don't think I have any...

    I never signed up. I don't think I have any business posting there either.
  45. Replies
    50
    Views
    5,779

    Mines 3 phase

    Mines 3 phase
  46. Replies
    11
    Views
    563

    It goes up if you get whatever you spray past the...

    It goes up if you get whatever you spray past the leak. If whatever you spray covers the leak it goes down.
    Needs to be a decent sized leak.
  47. Replies
    50
    Views
    5,779

    I just worked on a dispenser with the capacitor...

    I just worked on a dispenser with the capacitor hanging off the motor.... Hummmmmm
  48. Replies
    6
    Views
    329

    Looks like someone moved out of AOP to a...

    Looks like someone moved out of AOP to a different area.
    I'm not allowed to post in AOP. Was starting to sound like a FP commercial tough.
  49. Replies
    12
    Views
    619

    Best I've found are Cooper Atkins 4011 and if you...

    Best I've found are Cooper Atkins 4011 and if you have extreme ambient issues the small sensor is easily insulated where a scissors style clamp is not.
  50. Replies
    12
    Views
    619

    Why would you believe your new clamp that shows...

    Why would you believe your new clamp that shows warmer than your old clamp that you say is affected by air movement on a suction line? The only way to test your pipe clamp is against a property...