  1. Thread: Have you ever?

    by pecmsg
    Replies
    40
    Views
    1,107

    Your in a loose loose situation. SAFETY...

    Your in a loose loose situation.

    SAFETY FIRST!!!

    Knowingly releasing refrigerant
    Letting flanges leak / release

    This all sounds bad to me.
  2. Replies
    17
    Views
    258

    4-Tons for 1200 sq ft Zero dehumidification. 90%...

    4-Tons for 1200 sq ft
    Zero dehumidification. 90% of the time.

    It too damn big.
  3. Replies
    17
    Views
    258

    Duel fuel is the way to go. Heat pump with (in...

    Duel fuel is the way to go.
    Heat pump with (in your Case) LP back up. The Heat Pump down to say 20*F LP after that.
    Will cut your heating bills in 1/2 ?
  4. Replies
    17
    Views
    258

    A well insulated and tight 1200 Sq Ft home on...

    A well insulated and tight 1200 Sq Ft home on Long Island would get 1 1/2-Ton + or -heat pump!
    Ohio
    1 1/2 - 2-Tons
  5. Replies
    17
    Views
    258

    So what does that tell you? I question the 80K...

    So what does that tell you?

    I question the 80K heater as well but Iím not there.

    Have the 5-ton contractor post his calculations so we can see where the mistake is.
  6. Replies
    17
    Views
    258

    Iím not there so itís tough to see exactly what...

    Iím not there so itís tough to see exactly what you have.

    Get another estimate done
  7. Replies
    17
    Views
    258

    You still way oversized. and still some type of...

    You still way oversized.
    and still some type of backup is needed!
  8. Replies
    17
    Views
    258

    5-Tons for 1200 sq ft No need for back up ...

    5-Tons for 1200 sq ft

    No need for back up

    Keep looking for a good contractor!
  9. Maybe thatís the reason there are so many shady...

    Maybe thatís the reason there are so many shady techs!
  10. Replies
    4
    Views
    168

    Donate it to Habitat for humanity and put the...

    Donate it to Habitat for humanity and put the write off towards a qualified contractor
  11. Replies
    8
    Views
    155

    open Display cases are store temp and RH...

    open Display cases are store temp and RH Sensitive.
    Below 75* and 60%

    Above that and they wonít work
  12. Replies
    2
    Views
    131

    The installing contractor hopefully knows the...

    The installing contractor hopefully knows the local codes and the best way to run it!
  13. Thread: Mini split

    by pecmsg
    Replies
    3
    Views
    199

    Sorry but this is not a DIY Site

    Sorry but this is not a DIY Site
  14. You measure walls Windows Doors Search for...

    You measure
    walls
    Windows
    Doors

    Search for Manual ďJĒ calculation
  15. There are a# of sites that will do the calls with...

    There are a# of sites that will do the calls with you supplying the information
  16. Replies
    15
    Views
    731

    Single phase has 2 zero points 3 Phase 3 zero...

    Single phase has 2 zero points
    3 Phase 3 zero points

    How does that work?
  17. Replies
    21
    Views
    657

    How many times are you doing this? Why are you...

    How many times are you doing this?
    Why are you putting N2 in the air handler?
  18. Or DuPont's best piping practices

    Or
    DuPont's best piping practices
  19. I O M

    I O M
  20. Replies
    21
    Views
    657

    1/4Ē copper. What $20

    1/4Ē copper. What $20
  21. I agree with the Two comments above. Find a...

    I agree with the Two comments above.
    Find a contractor you can trust. Please keep in mind most are salesman!
  22. Replies
    3
    Views
    171

    I really donít care about the name on the boxís...

    I really donít care about the name on the boxís but more on the contractor.
    As far as R-410A you donít have a choice!
  23. Somethings wrong. We use a lot of micro...

    Somethings wrong.
    We use a lot of micro channels in refrigeration and Iíve only had 1 failure!
  24. Cant say ive ever collapsed tubes with just a...

    Cant say ive ever collapsed tubes with just a vacuum...……….there had to be other pressures involved!
  25. Thread: Have you ever?

    by pecmsg
    Replies
    40
    Views
    1,107

    Tires on the company truck start getting bald I...

    Tires on the company truck start getting bald I report it.

    When they get to the point of being unsafe AKA the indicators are wearing I don't drive that truck!
  26. Replies
    17
    Views
    663

    Licensed and Qualified are 2 different things! ...

    Licensed and Qualified are 2 different things!

    That work was done by "Unqualified, Unprofessional HACKS"

    Send the Pictures to your TSSA and HRAI and you "Might" get a response!
  27. Replies
    17
    Views
    663

    anyone who attempts to defend himself in a court...

    anyone who attempts to defend himself in a court of law, rather than retaining an attorney, "has a fool for a client."
  28. Replies
    17
    Views
    663

    Unfortunately you'll have to pay to get the...

    Unfortunately you'll have to pay to get the answers then possibly get reimbursed by the GC!

    Going to the GC with "On the web they said this and that" will get you exactly where you are now!
    ...
  29. Replies
    17
    Views
    663

    You need a Licensed & Qualified contractor to...

    You need a Licensed & Qualified contractor to inspect and advise what has to be done!

    Start with the manufactures web site for factory reps!
  30. ALL Heat pumps should have some type of Back Up!

    ALL Heat pumps should have some type of Back Up!
  31. Replies
    26
    Views
    1,027

    Looks normal except for the TV? But WTH...

    Looks normal except for the TV?

    But WTH ........................….Ive got a hammock
  32. And a few hundred at the scrap yard!

    And a few hundred at the scrap yard!
  33. Replies
    13
    Views
    346

    If you extend the arm its NOT rated and cant be...

    If you extend the arm its NOT rated and cant be used!
  34. @slickster I guess you get the point! Good...

    @slickster

    I guess you get the point!

    Good
    Target
    Perfect
    Within range

    Just doesn't cut it. Get back to us with facts and figures.
  35. Replies
    5
    Views
    198

    BTW You've got the post count...Apply for pro...

    BTW

    You've got the post count...Apply for pro status
  36. Replies
    5
    Views
    198

    Fixed Orifice-------------------Super Heat ...

    Fixed Orifice-------------------Super Heat

    X-valve------------------------Sub Cooling





    Keep pulling the charge
  37. There's been many times I just needed a second...

    There's been many times I just needed a second set of eyes!

    :cheers:
  38. Replies
    3
    Views
    189

    Is there a P-Trap on the floor drain? Should be...

    Is there a P-Trap on the floor drain? Should be by code!
    If you seal up the floor drain what are you going to do about the condensate?

    What's the humidity in the rest of the house?

    A...
  39. Dont know but the one below does so Access T...

    Dont know but the one below does so

    Access T with Schrader!

    I also see a shut off valve so ?????
  40. Thread: icomfort s30

    by pecmsg
    Replies
    8
    Views
    389

    How long does the unit run during the hot part of...

    How long does the unit run during the hot part of the day?
  41. Pressures great Super Heat perfect Nothings...

    Pressures great
    Super Heat perfect

    Nothings wrong

    Here's my bill!:grin2:
  42. Thread: XLI16

    by pecmsg
    Replies
    6
    Views
    269

    Keep searching for a tech that knows Super Heat,...

    Keep searching for a tech that knows Super Heat, Sub Cooling, Static Pressure and TESP!
  43. Replies
    4
    Views
    220

    Purge vapor off the top of the condenser.

    Purge vapor off the top of the condenser.
  44. Try a different contractor.

    Try a different contractor.
  45. Replies
    17
    Views
    663

    Get a different certified contractor to inspect...

    Get a different certified contractor to inspect and advise. You arguing with the contractor is a waste of time!

    Ducts not connected
    sharp metal edges

    Who inspected this, a home inspector? His...
  46. Replies
    17
    Views
    663

    Whoever did that work Is a HACK and shouldn't be...

    Whoever did that work Is a HACK and shouldn't be allowed to work with there tools.

    Why are you waiting contact the builder ands advise him you've been told NOT to use the equipment!
  47. Thread: GOODMAN

    by pecmsg
    Replies
    27
    Views
    825

    We do what we have to do!

    We do what we have to do!
  48. Replies
    7
    Views
    285

    Then you can change the speed!

    Then you can change the speed!
  49. Replies
    4
    Views
    227

    If the compressors on the fan MUST be on!

    If the compressors on the fan MUST be on!
  50. Thatís the way I see it!

    Thatís the way I see it!