Search:

Type: Posts; User: RLJN

Search: Search took 0.01 seconds.

  1. Replies
    55
    Views
    1,083

    The old ANNIE would let you "bump" or jog a stuck...

    The old ANNIE would let you "bump" or jog a stuck compressor by reversing the run and start windings but IIRC it would then put the run cap on the run winding rather than the start.

    You were...
  2. Replies
    55
    Views
    1,083

    Does the compressor ID tag match the cond unit ID...

    Does the compressor ID tag match the cond unit ID tag as far as 1 or 3 phase?

    If somehow a 3 phase compressor ended up in a 1 phase cond unit, and then the replacement was based on the compressor...
  3. Replies
    5
    Views
    411

    I live in a pretty small village in NE. Once or...

    I live in a pretty small village in NE. Once or twice a month end up in a large supermarket and walk thru the Coffee Aisle. Each time it reminds me of "Moscow on the Hudson" when the character of...
  4. Thread: This is odd

    by RLJN
    Replies
    13
    Views
    435

    Glycol getting slushy??

    Glycol getting slushy??
  5. Thread: This is odd

    by RLJN
    Replies
    13
    Views
    435

    Would the ground frost have reached it's deepest...

    Would the ground frost have reached it's deepest point now and just starting to come back up?

    Snow cover this year or not?
  6. Thread: This is odd

    by RLJN
    Replies
    13
    Views
    435

    Loop or pump and dump?

    Loop or pump and dump?
  7. Replies
    45
    Views
    797

    Is this thread still on the line? I couldn't...

    Is this thread still on the line?

    I couldn't see it anywhere.
  8. Replies
    4
    Views
    380

    Exactly! Now every day is like a Saturday or...

    Exactly!

    Now every day is like a Saturday or Sunday.

    But I feel bad for those who want to work needing the money.
  9. Replies
    45
    Views
    797

    I read thru a fair amount of the comments added...

    I read thru a fair amount of the comments added to the "Newspeak" article.

    One comment was that the "Berka/Burqa" was the "perfect garment for protection" from the plague and virus.

    So 2...
  10. Replies
    11
    Views
    673

    Agree, that much voltage drop top to bottom of...

    Agree, that much voltage drop top to bottom of contacts produces a lot of heat.
    The longer it runs the hotter it gets. This takes the temper out of the metals and then the snowball effect happens....
  11. Replies
    21
    Views
    1,076

    As stated above the cond pump is usually the only...

    As stated above the cond pump is usually the only means of venting the entire steam system.
    Any restriction such as this P-trap will impede the air removal.
    Just a vent pipe run straight up would...
  12. Replies
    21
    Views
    1,076

    Were there any piping instructions with the pump?...

    Were there any piping instructions with the pump? Usually would be. Follow those and you are right......by those standards. AHJ has the final say, no matter how conflicting to those instructions.
  13. Replies
    11
    Views
    896

    It takes at least pump pressure to open the flow...

    It takes at least pump pressure to open the flow check. Closing off the other zones might get it to open with fast fill pressure. I have loosened them by exercising the manual open function several...
  14. Replies
    11
    Views
    896

    Is that PRV open to fast fill? Should hear the...

    Is that PRV open to fast fill? Should hear the flow.
    There might be a manual open on the flow check which could be stuck.
  15. This is just a very expensive Jerry Springer...

    This is just a very expensive Jerry Springer Show..........the cheaper versions are much more educational and enlightening.
  16. If there is a common wall between WIC and WIF...

    If there is a common wall between WIC and WIF even that temp differential is enough to cause water vapor transfer via conduits. Actually any pipe going from inside to outside of a building needs...
  17. Replies
    52
    Views
    3,264

    Is this a gas furnace with the standard 120 VAC...

    Is this a gas furnace with the standard 120 VAC motor or heat pump air handler typically being 208/240 VAC? (some older heat pumps had a single speed for both heat and cooling)
  18. Replies
    76
    Views
    9,359

    Perhaps.... Forced Air Furnace.....

    Perhaps.... Forced Air Furnace.....
  19. Replies
    76
    Views
    9,359

    I have been a licensed electrician for 50 years. ...

    I have been a licensed electrician for 50 years. Moved back to small rural home town 40 years ago wanting to be self employed. Realized this would require more than one trade.
    So learned plumbing...
  20. Replies
    52
    Views
    3,264

    Are the unused speed taps isolated/insulated from...

    Are the unused speed taps isolated/insulated from the power?
    If you somehow energize more than one tap the motor OL would cut out.

    Are voltage, rotation and run cap correct?
  21. Replies
    17
    Views
    1,472

    For a small plug such as this I use the white...

    For a small plug such as this I use the white Teflon paste. Just wipe the top of the container with my finger and then apply around the pipe threads. The brush does too much IMO.
  22. Replies
    13
    Views
    2,958

    If that is a pool heater vented into the same...

    If that is a pool heater vented into the same space, was it running also?