Search:

Type: Posts; User: UrAverageAguy

Page 1 of 3 1 2 3

Search: Search took 0.02 seconds.

  1. Replies
    38
    Views
    3,159

    I meant to say I LIKE the concept behind this...

    I meant to say I LIKE the concept behind this install, itís very neat and definitely a layout I havenít thought of before. Thatís why I was curious on the angle on your vanes and how well the...
  2. Replies
    38
    Views
    3,159

    I think the concept/engineering behind this...

    I think the concept/engineering behind this install, although Iím still confused on how a horizontal install wouldnít have been any easier or cost effective? Also how did you determine the ďcorrectĒ...
  3. Replies
    1
    Views
    519

    RHEEM/RUUD

    Iím looking to find the refrigeration cycle diagram for a Residential RQPM 2-5 ton package heat pump. Does anybody know where I could find this literature?


    Sent from my iPhone using Tapatalk
  4. Replies
    36
    Views
    6,771

    I can see your theory being true especially in...

    I can see your theory being true especially in your climate and mine due to hot summers and high humidity. I think it would be easier to add a 3Ē strip if insulation on the outside to ďcushionĒ the...
  5. Replies
    12
    Views
    3,263

    One of Heils old factories is in my town, thereís...

    One of Heils old factories is in my town, thereís tons of those old furnaces, gas packs, and pkg heat pumps still running with original parts around here. I service them all the time but couldnít...
  6. Do you not worry that the nylon strapping will...

    Do you not worry that the nylon strapping will stretch over time? I fix a lot of duct work because the trunk was supported with nylon strapping.. great install though, thereís only a few of us in my...
  7. Replies
    6
    Views
    2,164

    I have a better idea. Give it to me and Iíll...

    I have a better idea. Give it to me and Iíll scrap it for $20


    Sent from my iPhone using Tapatalk
  8. Replies
    24
    Views
    5,315

    Painted the metal 90..now that is craftsmanship ...

    Painted the metal 90..now that is craftsmanship


    Sent from my iPhone using Tapatalk
  9. Replies
    17
    Views
    3,535

    I understand itís not good to make a customer...

    I understand itís not good to make a customer feel like they have something crappy installed on their house and when I come across stuff like that I donít sit on a bucket and complain about the extra...
  10. Replies
    4
    Views
    2,139

    Wow. Is that what they call ďthinking inside the...

    Wow. Is that what they call ďthinking inside the boxĒ


    Sent from my iPhone using Tapatalk
  11. Replies
    17
    Views
    3,535

    Hope you skipped lunch

    Well, Iím not trying to start a debate here but just because it passes code or an inspection doesnít mean itís right. The inspectors arenít the ones that have to work on these installs, so why would...
  12. Replies
    33
    Views
    4,089

    Iím not sure if the unit worked or not or why the...

    Iím not sure if the unit worked or not or why the gas is off. I opened the wrong door and had to take a picture before closing it and I hope I never have to step foot back in there again


    Sent...
  13. Replies
    33
    Views
    4,089

    How often do you find ďgoodĒ DIY work? Sent...

    How often do you find ďgoodĒ DIY work?


    Sent from my iPhone using Tapatalk
  14. Replies
    17
    Views
    3,535

    hmm that sounds like a very familiar solution ...

    hmm that sounds like a very familiar solution
    806504806505



    Sent from my iPhone using Tapatalk
  15. Replies
    14
    Views
    3,170

    That sounds like a never ending nightmare ...

    That sounds like a never ending nightmare


    Sent from my iPhone using Tapatalk
  16. Replies
    33
    Views
    4,089

    Lol I hear that at 90% of the houses/businesses I...

    Lol I hear that at 90% of the houses/businesses I work on. Everybody wants the best equipment and the best job but sure acts like youíve stabbed them when you mention what it will cost to make that...
  17. Replies
    33
    Views
    4,089

    Sounds like one big monopoly thatís been going on...

    Sounds like one big monopoly thatís been going on for at least 30 years now. Haha


    Sent from my iPhone using Tapatalk
  18. Replies
    33
    Views
    4,089

    I could agree with you there, especially with the...

    I could agree with you there, especially with the restricted filter it has to get the air from somewhere. Maybe thatís why this dentist office doesnít put people to sleep for surgeries, the gases in...
  19. Replies
    33
    Views
    4,089

    The brown ďcardboardĒ looking things on the...

    The brown ďcardboardĒ looking things on the ground below the water heater were the other 3 filters that replaced in the life span of the unit. Let me also mention that it was a solid wood door that...
  20. Replies
    33
    Views
    4,089

    806420806421806422 Sent from my iPhone using...

    806420806421806422


    Sent from my iPhone using Tapatalk
  21. Replies
    33
    Views
    4,089

    Opened the wrong door..

    How often do yíall see something that you wish you wouldnít have? I wasnít even there to look at the unit, who knows if it works or not but I wanted to see how many code violations yíall could count?...
  22. Replies
    9
    Views
    1,641

    I tried to warn them about it. I have to go back...

    I tried to warn them about it. I have to go back and install a couple LED lights for them so I thought I would at least run some 1/2 lag bolts through the foundation underneath the side thatís washed...
  23. Replies
    9
    Views
    1,641

    Heating and cooling systems are the last things...

    Heating and cooling systems are the last things on peopleís minds, until they quit working or it ďruinsĒ their plans or what theyíve imagined in their new/old homes. They expect us to snap our...
  24. Replies
    9
    Views
    1,641

    Well I tried to politely emphasize that I would...

    Well I tried to politely emphasize that I would prefer nothing in front of it but obviously itís not my yard to have an opinion. I tried telling them that more support under the pad and gravel would...
  25. Replies
    9
    Views
    1,641

    They were talking about planting more trees when...

    They were talking about planting more trees when I was finishing up the final touches....I asked them kindly to please keep it something small since all my controls and service panels were on the...
  26. Replies
    9
    Views
    1,641

    Just a PKG unit

    Got the call for no Air movement, it had a basement style Crawlspace so I checked the duct first. Itís 16Ē return on an 3.5 ton unit. So then I checked the unit and the control board had fried (very...
  27. Replies
    2
    Views
    668

    Thank you for your help, I finally forced my...

    Thank you for your help, I finally forced my local distributors to admit that Quietside is part of Samsung and that they could get the parts Iím looking for. They found my OEM part and now I know to...
  28. Replies
    2
    Views
    668

    Need some help

    I have a old Quietside Heat Pump mini split,13 Seer. The indoor gave me a 7 pulse flash code, outdoor coil sensor issue. I have verified that Iím getting 5vDC from the air handler as Iím supposed to....
  29. Replies
    36
    Views
    6,771

    I see undersized duct at 90% of the houses I go...

    I see undersized duct at 90% of the houses I go to. I lose several change outs because I price them to add vents or increase the duct size. Itís honestly impressive to see how tough some of the R22...
  30. Replies
    36
    Views
    6,771

    I told the builder from the start that I didnít...

    I told the builder from the start that I didnít like it, for one not only the install was harder but service work is more of a pain and for future replacement. Every option I offered got turned down...
  31. Replies
    36
    Views
    6,771

    I agree with the conduit, normally I do run it in...

    I agree with the conduit, normally I do run it in conduit but it didnít happen on this job. I split the return between the living room and the master bed. Even with the door open I donít believe it...
  32. Replies
    20
    Views
    2,755

    Yeah in my area they are more worried about the...

    Yeah in my area they are more worried about the tape we use instead of failing houses with 4 ton units on 2 ton duct systems. Iíve started using duct butter to cut down on the rolls of mastic.

    ...
  33. Replies
    27
    Views
    5,368

    shark bites and lock tite is my way out of a...

    shark bites and lock tite is my way out of a pinch


    Sent from my iPhone using Tapatalk
  34. Replies
    20
    Views
    2,755

    We have to use mastic on anything thatís metal to...

    We have to use mastic on anything thatís metal to metal. Taps, seams, joints, everything. On one small duct job itís easy to use 2-3 rolls of mastic and we all know how cheap it is and how itís a...
  35. Replies
    20
    Views
    2,755

    Looks good! I like the return plenum/stand, also...

    Looks good! I like the return plenum/stand, also like the time and detail you spent making everything look as neat as it does. My only question is why the duct board? I know some people like it more...
  36. Replies
    27
    Views
    5,368

    I was assuming itís probably installed wrong and...

    I was assuming itís probably installed wrong and they didnít notice it because they spent to much time working on the art of that suction line. But for the sake of the Compressor letís just hope is a...
  37. Replies
    27
    Views
    5,368

    That thermostat wire looks awfully small... ...

    That thermostat wire looks awfully small...


    Sent from my iPhone using Tapatalk
  38. Replies
    36
    Views
    6,771

    You can see it plain as day that it stops right...

    You can see it plain as day that it stops right below the unit. I told the builder that I didnít have the fire damper access door installed on the supply side or the brackets sealed around the damper...
  39. Replies
    36
    Views
    6,771

    Thank you, I try my best to think ahead and...

    Thank you, I try my best to think ahead and definitely put pride into everything I touch. Even if itís a old POS haha


    Sent from my iPhone using Tapatalk
  40. Replies
    36
    Views
    6,771

    The main breaker panel is about 10í away from the...

    The main breaker panel is about 10í away from the unit.


    Sent from my iPhone using Tapatalk
  41. Replies
    36
    Views
    6,771

    I thought about it but the support brackets had...

    I thought about it but the support brackets had to go in first either way and once they were in place I knew that was my best opportunity to seal my duct connections, and no I didnít screw anything...
  42. Replies
    36
    Views
    6,771

    The top is rocked but they couldnít get behind...

    The top is rocked but they couldnít get behind it. The drywall stops at the top of the bracket. Is it bad to say that I wanted the unit in place before they put the drywall up.


    Sent from my...
  43. Replies
    36
    Views
    6,771

    Acont624. The 824 is better and the 1050 is the...

    Acont624. The 824 is better and the 1050 is the betterest. Great thermostats


    Sent from my iPhone using Tapatalk
  44. Replies
    36
    Views
    6,771

    I didnít have anymore glue for the insulation and...

    I didnít have anymore glue for the insulation and settled for tape but was regretting it after doing so..I hate the way tape looks


    Sent from my iPhone using Tapatalk
  45. Replies
    36
    Views
    6,771

    The secondary port has a inline float switch...

    The secondary port has a inline float switch thatís capped off. I do have a trap but was worried it might drip water on his work bench this summer so I insulated the drain line.


    Sent from my...
  46. Replies
    36
    Views
    6,771

    Nothing special

    Itís nothing to Fancy but Iím proud of it, I hope yíall donít burn me to bad..

    I went with 1.5 ton w/ 2 ton TAM9, I still have a couple touch ups to do on the install. They sent the wrong fire...
  47. Your right, the longer you I look these pictures...

    Your right, the longer you I look these pictures the worse it gets. One thing is for sure...they did a great job at doing things wrong


    Sent from my iPhone using Tapatalk
  48. It almost looks like they ran the liquid line...

    It almost looks like they ran the liquid line through the condensate drain port for vertical installations. And of course taped over the actual liquid line port.


    Sent from my iPhone using...
  49. Well hopefully they showed up without the ďlate...

    Well hopefully they showed up without the ďlate Friday afternoon attitudeĒ this time and fixed everything properly.


    Sent from my iPhone using Tapatalk
  50. Just noticed that the Rev. Wire at the condenser...

    Just noticed that the Rev. Wire at the condenser is wired in for constant AC. Can you explain whatís going on there? Please tell me the HO donít have to rely on EM heat as their primary heat because...