  1. Email their tech support, they're quicker then...

    Email their tech support, they're quicker then asking the controls forum here.
  2. Screw terminal seems best imo, the push locks...

    Screw terminal seems best imo, the push locks works as well when done right but getting the wire in there without having strands fold back is a pain sometimes. Also straight wire is prefered for me....
  3. Replies
    3
    Views
    561

    Code is 6363, go to menu, and look for something...

    Code is 6363, go to menu, and look for something related to communication and input your info there. The RTU should have documentation inside of them guiding you how to configure BACnet settings.
  4. It all depends on how the NET ports were setup...

    It all depends on how the NET ports were setup when that controller was commissioned. They can be disabled for all you know and you won't get anywhere. First look at NET1 because that's the port...
  5. Replies
    10
    Views
    618

    Lol so speaking of the fuse, we had some...

    Lol so speaking of the fuse, we had some balancers come out and play with the MT3 controller to adjust the OAD position and incidentally the controller died. Daikin told me to check the fuse and I...
  6. Nope, Getting ORCAview or a Delta licensed...

    Nope,

    Getting ORCAview or a Delta licensed work bench is the only way to program and edit those objects and believe me, I tried cracking/breaking into it, it's hard. I don't know if a generic...
  7. Replies
    6
    Views
    445

    Yeah that's right, so they use this venturi valve...

    Yeah that's right, so they use this venturi valve to control airflow into the room and out of the room, so on the supply and return. Using that they can set different positive/negative static...
  8. Replies
    12
    Views
    4,307

    So I'm trying to modify my WEBS 4.10.1 workbench...

    So I'm trying to modify my WEBS 4.10.1 workbench and there's only one theme, the Honeywell one and every time I modify anything it all, workbench doesn't want to open. Some error shows up on the...
  9. Replies
    12
    Views
    4,307

    Bump yeah I can't get my theme to show up under...

    Bump yeah I can't get my theme to show up under the drop down menu either.
  10. Replies
    21
    Views
    1,272

    Honeywell CIPer 10, CIPer30 and CIPer50 run...

    Honeywell CIPer 10, CIPer30 and CIPer50 run Niagara natively.
  11. Replies
    5
    Views
    776

    Try running another station on it, or you can...

    Try running another station on it, or you can start from scratch, load a clean dist file on it, commission a different good working station and see if you got the same issue. Try the station on...
  12. Replies
    219
    Views
    128,622

    Heard Spyder5 unitary controllers are 5-8 months...

    Heard Spyder5 unitary controllers are 5-8 months lead time as well
  13. Replies
    5
    Views
    776

    It should be grounded as well the power supply...

    It should be grounded as well the power supply you're using should be as well but I doubt that is what's causing your issue. There's a thousand things that can cause your JACE to slow down. Start...
  14. Replies
    219
    Views
    128,622

    Insane, 13% increase in cost in controllers. What...

    Insane, 13% increase in cost in controllers. What do you even do with that when you're bidding for projects, win the bid and hear this?
  15. You're screwed unless you either got the physical...

    You're screwed unless you either got the physical USB key or an enteliweb license which only a vendor can purchase for you. For the enteliweb license, your DAC-1146E needs to be connected to a system...
  16. Replies
    180
    Views
    17,016

    Shout out to Gwilliams

    Shout out to Gwilliams
  17. Replies
    16
    Views
    748

    Hmm well you're kinda screwed then man without...

    Hmm well you're kinda screwed then man without buying the 4.9 Supervisor unless someones got the 4.9 modules.
  18. Replies
    16
    Views
    748

    What kind of points? Whenever I integrated this I...

    What kind of points? Whenever I integrated this I would discover all the points I need over BACnet.
  19. Replies
    16
    Views
    748

    FYI they do have 4.9 JACEs on their site

    FYI they do have 4.9 JACEs on their site
  20. Replies
    16
    Views
    748

    How about tying into the BACnet network of the...

    How about tying into the BACnet network of the LMBCs to your JACE?
  21. Replies
    16
    Views
    748

    I don't think you can, when I used to...

    I don't think you can, when I used to commission/program Wattstopper they never gave/licensed me for their work bench so I was only able to access the JACE through a web browser. Only a Wattstopper...
  22. Replies
    37
    Views
    11,047

    I'm using the TC500 on a job right now, it's...

    I'm using the TC500 on a job right now, it's pretty straight forward and easy to setup. We connected it to a JACE wifi and discovered all the bacnet points, theoretically if you wanted too, you could...
  23. Replies
    3
    Views
    523

    Pictures of the diagram would be nice

    Pictures of the diagram would be nice
  24. You mean like having a modem connected to it and...

    You mean like having a modem connected to it and you forward the IP of the JACE to the modem and remote connect to the modem?
  25. Replies
    37
    Views
    2,327

    Always good, I have a yearly review and plan on...

    Always good, I have a yearly review and plan on doing so. Especially with inflation being as insane as it is right now.
  26. Replies
    37
    Views
    2,327

    Yeah I realized all of that, that wasn't really...

    Yeah I realized all of that, that wasn't really in my cards until later on. Luckily here non compete clauses aren't legal in Ontario so I could open a company if I wanted to but it needs a lot of...
  27. Replies
    37
    Views
    2,327

    Oh this is a new job, I left another controls...

    Oh this is a new job, I left another controls company 6-7 months ago for this one because it pays much better. Pay here is pretty decent, that's not the issue. I just bought a place recently and I...
  28. Replies
    37
    Views
    2,327

    Eh, we're not super busy but not dead either. I'm...

    Eh, we're not super busy but not dead either. I'm doing something like 44 hour weeks. Work usually slows down a bit in winter .
  29. Replies
    37
    Views
    2,327

    Anyone do weekend work?

    I'm trying to earn a bit of extra cash as things are tight right now and was trying to come up with good ideas of weekend/evening work that I could do. I'm curious to see if anyone is doing anything...
  30. Replies
    12
    Views
    1,098

    https://www.irisys.net/products/safecount-occupanc...

    https://www.irisys.net/products/safecount-occupancy-monitoring-solution paired with https://store.chipkin.com/products/irisys-people-counter-to-bacnet-gateway.

    If you search up occupancy counter...
  31. Replies
    5
    Views
    1,249

    Linknet thermostats can't be on the same network...

    Linknet thermostats can't be on the same network at BACnet devices, those are two different com protocols so you have to move them to a different network port. It sounds like you have an ethernet...
  32. Delta's got pretty good tech support if you can...

    Delta's got pretty good tech support if you can still login into Delta Controls Passport
  33. Replies
    5
    Views
    788

    Also the code to configure the Microtech...

    Also the code to configure the Microtech controller is by default 6363
  34. Installing a CT right on the incoming line before...

    Installing a CT right on the incoming line before it goes anywhere on the unit should negate that no? Whether you have an ECM or vari speed comp, your current drawn will go up/down at the line side.
  35. Replies
    5
    Views
    788

    Search up the engineering guide of that...

    Search up the engineering guide of that controller, I'm sure it exists as I've come across them and hooked them up. They have onboard menu on the controller itself which you have to configure for BMS...
  36. It depends on the situation imo, you can use an...

    It depends on the situation imo, you can use an analog CT to differentiate between a unit running on fan only and when it turns on a compressor so it can technically save you money from putting in...