Search:

Type: Posts; User: Dchappa21

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Thread: New SMAN380V

    by Dchappa21
    Replies
    7
    Views
    795

    I just got the new SMANs and I agree with u.. I...

    I just got the new SMANs and I agree with u.. I didn't have the fieldpiece probes, but now feel like I need them to have a complete set... So I ordered the wireless probes kit, and can't wait till...
  2. Replies
    12
    Views
    1,017

    Yeah, something on the actual manifold without ...

    Yeah, something on the actual manifold without having to plug in to check the data log would be handy, at least for me and all my co workers. Something that u can clear when u want and doesn't clear...
  3. Replies
    12
    Views
    1,017

    Ok Russ I bought these and have been using them...

    Ok Russ I bought these and have been using them all week. So far so good. Just wanted to check with you and see if there is a way to see the min, max psig over a period? I use this function almost...
  4. Replies
    12
    Views
    1,017

    Thanks Russell, I assume it's the same for the...

    Thanks Russell, I assume it's the same for the SMAN480? They will still work in the same low temps?
  5. Replies
    12
    Views
    1,017

    Will the wireless temp clamps work below 32...

    Will the wireless temp clamps work below 32 degrees? I see they are rated for between 32°-122°f. Looking to use these around 0°f or below ambient temp. Is that rating just what all the specs we're...
  6. Replies
    15
    Views
    1,811

    I see the wireless temp clamps say opperating...

    I see the wireless temp clamps say opperating temp 32f-122f. Does this mean they won't work in a frozen case or WI freezer to get a temp reading due to the ambient temperature?
  7. Replies
    15
    Views
    1,811

    Ok thanks, I was more interested in the distance...

    Ok thanks, I was more interested in the distance on the pipe clamps anyway for refrigeration. That's pretty sweet, think this will be my next manifold!
  8. Replies
    15
    Views
    1,811

    Are the wireless probes good for 350' to the SMAN...

    Are the wireless probes good for 350' to the SMAN (clear path). Then another 350' from the SMANs to your phone or tablet??
  9. Replies
    15
    Views
    1,811

    My guess is the getting ride of old stock. The...

    My guess is the getting ride of old stock. The new SMAN 480 and 380 are set to come out sometime in April from what I hear.
    ...
  10. Do your testos go back to zero after you've been...

    Do your testos go back to zero after you've been working on a system? Got a coworker that bought the 557s a couple of weeks ago and his are always off by a few inches or psi after he works on a...
  11. LMFAO

    LMFAO
  12. The new SMAN 480 has an IP 54 rating, not bad....

    The new SMAN 480 has an IP 54 rating, not bad. Anyone know what the current SMAN is? I've always just used the Digi-Cools not sure what there IP class is but I know it doesn't mind lots of water or...
  13. I'm just the opposite, I can't image going back...

    I'm just the opposite, I can't image going back to a set of analogs and a pt chart. Been using digital gauges for over 12 years now. I don't even really look at the pressures, just the saturation...
  14. New Sman looks pretty cool, been looking for a...

    New Sman looks pretty cool, been looking for a new digital manifold or smart gauges for a little while now... Just hope it will have r448a in it or able to update it. ...
  15. Replies
    56
    Views
    2,502

    Balance port valves are pretty much all we have...

    Balance port valves are pretty much all we have installed for many many years now, and yes it's because they can be used with low liquid pressure. Thats the main reason to use a balance port for...
  16. Replies
    28
    Views
    2,460

    Not to hijack, but has anybody heard when...

    Not to hijack, but has anybody heard when Inficons latest and greatest leak detector is coming out. I believed it was called Stratus, and had a ppm display one it. Looked pretty cool.
  17. Replies
    6
    Views
    695

    I use an a421 to replace a lot of dixell controls...

    I use an a421 to replace a lot of dixell controls on self contains sometimes with a relay or contactor and sometimes just the tstat. Depends on the current draw and location.
  18. Replies
    56
    Views
    3,518

    Something I found odd with 448a was the listed...

    Something I found odd with 448a was the listed defrost times from Zero Zone for a multideck med temp case was 6 times a day vs 4 times a day with 404a.
  19. Thread: Ardco Doors

    by Dchappa21
    Replies
    7
    Views
    649

    Try Case parts or Ref hardware supply. Plenty of...

    Try Case parts or Ref hardware supply. Plenty of pics in the catalogs to look at for help pinpointing what you need.
  20. Replies
    18
    Views
    883

    Good catch. I just assumed it had a distributor....

    Good catch. I just assumed it had a distributor. Haven't seen a new WI evap without on in the last 20 years lol.
  21. Replies
    18
    Views
    883

    It won't feed properly, you'll have a low suction...

    It won't feed properly, you'll have a low suction pressure. Re-use the old one or like pecmsg said install it temporarily. I would suggest having a sporlan kit on the truck. You can build a valve...
  22. Replies
    81
    Views
    2,825

    Make sure there is not a little 032 drier up...

    Make sure there is not a little 032 drier up stream of the valve in the case... Seen those plug up a bunch of times.
  23. Replies
    18
    Views
    1,666

    If you haven't already, clean the condenser coil,...

    If you haven't already, clean the condenser coil, 300 psi is pretty high. You can also look to see the mcc of the compressor (maximum constant curret) my guess is your under that. WAG is that it's...
  24. Replies
    41
    Views
    3,594

    Pressures of r290 will be about the same as...

    Pressures of r290 will be about the same as r22... R32 may be next up in the resi world. But your already using it today, its in 410a. R32 is also flammable (A2L).
  25. Replies
    14
    Views
    1,330

    Viper and rinse with water in a pump spayer. I...

    Viper and rinse with water in a pump spayer. I only use nitrogen on ice machines that I don't want coil cleaner going into the bin.
    I got some old Tupperware that I have in my truck to cat water.....
  26. Thread: Once again

    by Dchappa21
    Replies
    3
    Views
    826

    Looks pretty cool!! Price yet?

    Looks pretty cool!! Price yet?
  27. Replies
    15
    Views
    1,469

    Correct.

    Correct.
  28. Replies
    15
    Views
    1,469

    It's a few hundred more than the Bosch for me.

    It's a few hundred more than the Bosch for me.
  29. Replies
    15
    Views
    1,469

    It's one or the other from what I understand. You...

    It's one or the other from what I understand. You need to switch a dip switch or 2 to switch to 37 degree coil. Looks like it comes set for 47.
  30. Replies
    15
    Views
    1,469

    What would be the matching evap coil for this...

    What would be the matching evap coil for this unit? Looked on my suppliers site and the price isnt to bad for that condensing unit. I will look into that unit, thanks. Have you installed many of the...
  31. Replies
    15
    Views
    1,469

    Maybe the TM9E doesn't have y1 and y2 , I've been...

    Maybe the TM9E doesn't have y1 and y2 , I've been looking at a lot of manuals, I have to try and look later. And I'll look in to the TM9Y, thanks.
  32. Replies
    15
    Views
    1,469

    Thanks rundawg. I can get a really good price on...

    Thanks rundawg. I can get a really good price on the Bosch unit, so I figured why not try it. It's got a ten year warranty like all the other units. And it can ramp all the way down to 25 percent so...
  33. Replies
    15
    Views
    1,469

    York standard ecm

    Don't really do much residential , but looking to replace my furnace and AC unit.
    Looking at York TM9E080C16MP11
    And going to use a Bosch bova 36 heat pump with a 3 ton coil.
    Is the "standard...
  34. Thread: Coil gun

    by Dchappa21
    Replies
    20
    Views
    2,093

    Yeah they work great. No more sore arm from...

    Yeah they work great. No more sore arm from pumping your pump sprayer. I don't use the foaming tip though. I like the little small piece to fan out the spray. Or I'll use it without any tip on really...
  35. Thread: Refco Tap

    by Dchappa21
    Replies
    42
    Views
    4,241

    Good to know. Guess they wouldn't be a good...

    Good to know. Guess they wouldn't be a good choice to set up superheat on a frozen line up.

    Did you have the gauge hooked up too? Don't hey have the same temp range 32-122?
  36. Thread: HFC Ban Off

    by Dchappa21
    Replies
    12
    Views
    2,205

    Put some Zero Zone self-contains in last week,...

    Put some Zero Zone self-contains in last week, they came with R448a in them. The medium temp Hydra Cool units had 404a in them though. The build date on them were from 2017.. Doing a couple more...
  37. Thread: Refco Tap

    by Dchappa21
    Replies
    42
    Views
    4,241

    Hahaha, cut slow!

    Hahaha, cut slow!
  38. Thread: Refco Tap

    by Dchappa21
    Replies
    42
    Views
    4,241

    Adding ref doesn't seem like it would be bad with...

    Adding ref doesn't seem like it would be bad with just a tee or valve core tool. Suppose you could just screw them on a manifold if you really wanted and just pull them off as needed.
  39. Thread: HFC Ban Off

    by Dchappa21
    Replies
    12
    Views
    2,205

    The big refrigeration companies have to much...

    The big refrigeration companies have to much money invested in these earth saving new flavors, they will get their way eventually. But for now 404a is back to being legal for installs. Think...
  40. Thread: Refco Tap

    by Dchappa21
    Replies
    42
    Views
    4,241

    Nice, thanks for your time and thoughts Iceman....

    Nice, thanks for your time and thoughts Iceman. Think I'll be ordering a set soon.. Can't believe it took Refco to make a wirless set with sat and psig reading on the tool and display the temp...
  41. Thread: Refco Tap

    by Dchappa21
    Replies
    42
    Views
    4,241

    Clamps not tight enough or air giving false...

    Clamps not tight enough or air giving false reading?? Guessing distance is comparable to Appions and testo and all the others?

    Do you know if the psi drifts with temp change yet?
  42. Thread: Refco Tap

    by Dchappa21
    Replies
    42
    Views
    4,241

    Refco Tap

    Since it got lost in the big crash, I'll start another one. Anybody get em yet? I see Tru tech still says they ship in 5-10 days.
  43. Replies
    14
    Views
    1,842

    Looks good, only thing I would add is traps to...

    Looks good, only thing I would add is traps to the drains, its going to suck in a lot of hot air in the summer. Any pics of the cond units?
  44. Replies
    17
    Views
    3,058

    Pricing I got was from Bell Simons Company.

    Pricing I got was from Bell Simons Company.
  45. Replies
    4
    Views
    899

    Yup! Gets my vote! Multiple temp probes off one...

    Yup! Gets my vote! Multiple temp probes off one transducer like sporlan pro would be nice too :.02:
  46. Replies
    267
    Views
    24,562

    I'll place my order for the W2000 right now :D...

    I'll place my order for the W2000 right now :D ....
    Still using my 1200s and 1250s, going on 10 years now. Been waiting for a digital wireless manifold with a display on it, that's not a testo.
  47. Replies
    60
    Views
    4,692

    Know this is an old thread, but please don't...

    Know this is an old thread, but please don't insulate an accumulator. I have changed a bunch that were insulated and rusted out. I've yet to replace one that wasn't insulated.... They don't come...
  48. Replies
    52
    Views
    4,959

    Looks good so far. Is the drain going to be...

    Looks good so far. Is the drain going to be trapped out side with heat tape before it goes into the cup?

    Also you do know 404a is being phased out right? If you installed this after jan 1 2018 you...
  49. Replies
    17
    Views
    3,058

    Got a price today $740 for 2 pressure sensors...

    Got a price today $740 for 2 pressure sensors ($205 each) and 2 temp sensors (165 each)... think I'll wait a year should be half the price like the original smart tool is now. I'll stick with the...
  50. Replies
    17
    Views
    3,058

    Thanks.. think I might pick these up soon. Tried...

    Thanks.. think I might pick these up soon. Tried asking one of the supply houses today and of course never heard of the new pro/r version.
    Anyone have a ball park price for the new version (2...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4