  1. Replies
    24
    Views
    803

    That is some seriously impressive insulation work!

    That is some seriously impressive insulation work!
  2. Replies
    45
    Views
    1,779

    410A has almost no glide. I wouldn’t worry at all...

    410A has almost no glide. I wouldn’t worry at all about pumping it down or topping it off.

    Scrolls pump down just fine, they are common on pump down refrigeration systems. Sometimes they rattle a...
  3. Thread: 404A

    by Red Man
    Replies
    12
    Views
    591

    The glide on 404A is very low. I don’t even think...

    The glide on 404A is very low. I don’t even think twice about topping it off.
  4. Replies
    10
    Views
    890

    Nope, no solution...the dispatcher still sucks.

    Nope, no solution...the dispatcher still sucks.
  5. Thread: Strange

    by Red Man
    Replies
    19
    Views
    1,128

    ...Under boobs :yes::yes:

    ...Under boobs :yes::yes:
  6. Thread: Strange

    by Red Man
    Replies
    19
    Views
    1,128

    Might be broke.

    Might be broke.
  7. Replies
    13
    Views
    747

    I work on ammonia systems. All are large systems,...

    I work on ammonia systems. All are large systems, mostly food processing plants.
  8. Replies
    10
    Views
    1,230

    The type with a coalescer element and the type...

    The type with a coalescer element and the type with a float and needle valve will have different methods for determining failure. Both types are are rebuildable.
  9. Replies
    18
    Views
    1,145

    I say go for it. Small refrigeration is my least...

    I say go for it. Small refrigeration is my least favorite kind of work. I much prefer large HVAC and large refrigeration. It is tough working on a huge variety of stuff and being expected, by the...
  10. Replies
    20
    Views
    1,086

    I’m gonna say the frozen coil caused a liquid...

    I’m gonna say the frozen coil caused a liquid slug to take out the compressor. When the compressor isn’t pumping, the evap superheat is a meaningless number.
  11. Replies
    2
    Views
    281

    Verify the JCI controllers have power. If they do...

    Verify the JCI controllers have power. If they do have power, you could try power cycling them.
  12. Replies
    24
    Views
    767

    The app does not make up for the extras that the...

    The app does not make up for the extras that the micro is missing.
  13. Replies
    24
    Views
    767

    I just have the micro, it’s cheaper than the JB...

    I just have the micro, it’s cheaper than the JB gauge. The pro would be nice.
  14. Replies
    24
    Views
    767

    Here’s a 5 ton split heat pump I did recently. 15...

    Here’s a 5 ton split heat pump I did recently. 15 minutes to 120 microns. Held below 150 for 10 minutes.
    808695
  15. Thread: Pulsing in TXV

    by Red Man
    Replies
    44
    Views
    1,514

    The superheat, subcooling, and air temps are all...

    The superheat, subcooling, and air temps are all needed to tell if the txv is actually the problem or if there’s a liquid restriction or just a low load. The OP found a dirty blower wheel, so the...
  16. Replies
    24
    Views
    767

    Yes, it’s very limiting. I highly recommend...

    Yes, it’s very limiting. I highly recommend getting a couple Appion large diameter hoses and core removal tools.
  17. Replies
    85
    Views
    5,744

    I got no problem going on commercial roofs, resi...

    I got no problem going on commercial roofs, resi roofs are different. They’re steeper and it’s a lot scarier getting on and off the ladder.
  18. Replies
    4
    Views
    436

    Ammonia subcoolers are typically not fan coils,...

    Ammonia subcoolers are typically not fan coils, they are more like what icemeister posted. It can be done with plate and frame or shell and tube heat exchangers. Is this system going to have an...
  19. Yup, me too :cheers:

    Yup, me too :cheers:
  20. I wouldn’t use that one. That stat can’t go...

    I wouldn’t use that one. That stat can’t go outside and doesn’t have a remote bulb. It could go in the economizer hood, but that would not be ideal. The OP needs a stat with a cap tube and bulb.
  21. You could use a ranco etc, or a mechanical stat...

    You could use a ranco etc, or a mechanical stat with a cap tube and sensing bulb. Find one where your desired set point is somewhere near mid range of the stat. Just run the Y circuit through the...
  22. Replies
    133
    Views
    7,551

    He comes back all the time! He was just here the...

    He comes back all the time! He was just here the other week showing off his all bun burgers he was eating because he had no work to do.
  23. Replies
    133
    Views
    7,551

    Doesn’t seem like the guru to me. Seems like a...

    Doesn’t seem like the guru to me. Seems like a thin skinned rookie. Kinda like the guru before we beat him down so many times.
  24. Thread: Beef jerky

    by Red Man
    Replies
    14
    Views
    1,239

    Looks great!

    Looks great!
  25. Thread: PM time

    by Red Man
    Replies
    103
    Views
    3,776

    ::DD: I’d be too ashamed to post that pic if...

    ::DD:
    I’d be too ashamed to post that pic if that’s what my burgers looked like.
  26. Whattttt...I use my combustion analyzer at least...

    Whattttt...I use my combustion analyzer at least weekly, even during the summer! Well...maybe every other week occasionally.
  27. Thread: PM time

    by Red Man
    Replies
    103
    Views
    3,776

    Maybe you should start your own tech support...

    Maybe you should start your own tech support business. Tech support for all types of equipment, just call the hvac guru! $2 per minute and you can just bill the customer for the cost!
  28. Replies
    59
    Views
    1,799

    Poll: I agree. I don’t see the benefit of having four...

    I agree. I don’t see the benefit of having four new forums to cover a subject that seems to come up infrequently. I think it makes sense to lump it into residential appliances.
  29. My universal zebra ecm motor tester.

    My universal zebra ecm motor tester.
  30. Thread: PM time

    by Red Man
    Replies
    103
    Views
    3,776

    You must be really bored.

    You must be really bored.
  31. Replies
    5
    Views
    340

    I have no problem with the magnet strap.

    I have no problem with the magnet strap.
  32. The low discharge temps would be due to the flood...

    The low discharge temps would be due to the flood back you were getting. What were your pressures/temps after the repair?
  33. So you evacuated the condenser...that likely...

    So you evacuated the condenser...that likely removed the non condensables that were causing your problems.
  34. Something is not adding up here. I’ve worked on...

    Something is not adding up here. I’ve worked on these Masterbuilt condensing units for -40 walk ins. The ones I worked on had two stage Bitzer compressors. They were 404A and had 180# headmasters....
  35. So you’re saying it was overcharged to compensate...

    So you’re saying it was overcharged to compensate for a bypassing headmaster?
  36. Replies
    144
    Views
    6,761

    Yes...a meme is a picture with a “funny” caption.

    Yes...a meme is a picture with a “funny” caption.
  37. Replies
    144
    Views
    6,761

    I just downloaded tapatalk just to see...

    I just downloaded tapatalk just to see it...definitely a meme with a racial slur, I don’t see how anyone could think otherwise. He must’ve been drunk, he normally seems like a good guy in his posts....
  38. Replies
    144
    Views
    6,761

    Who’s Cheri?

    Who’s Cheri?
  39. Replies
    31
    Views
    2,719

    I’ve seen a sporlan liquid line solenoid leak...

    I’ve seen a sporlan liquid line solenoid leak from the stem once. It was in a beer walk in. No pitting on the stem, just leaking.
  40. Replies
    144
    Views
    6,761

    He said he confirmed that if he called in an...

    He said he confirmed that if he called in an order his “helper” could pick it up. His “helper” is you. He asked what model to order and you ignored him. :gah:
  41. Replies
    53
    Views
    9,181

    There’s still good trade schools. I went through...

    There’s still good trade schools. I went through a two year program at my local tech school 8 years ago. The teacher had decades of experience and had a full understanding of why things are the way...
  42. Replies
    31
    Views
    1,392

    I personally don’t see why propress is considered...

    I personally don’t see why propress is considered ok and sharkbites aren’t. They both have an o ring seal and a means of keeping the pipe from popping out of the fitting. I much prefer soldering. A...
  43. Replies
    59
    Views
    5,334

    Does R to C measure 24 V? If it does, what do...

    Does R to C measure 24 V? If it does, what do mean there’s no power to the stat. If it doesn’t, does the transformer secondary measure 24 V?
  44. Replies
    72
    Views
    3,744

    My bag I bring in to almost every call is pretty...

    My bag I bring in to almost every call is pretty big, it probably weighs 30 pounds. I do a lot of commercial and industrial work and a trip to the van could easily take 15 minutes, sometimes 30...
  45. Replies
    72
    Views
    3,744

    ::DD:

    ::DD:
  46. Replies
    59
    Views
    5,334

    But if everything is good it must be working...

    But if everything is good it must be working fine!

    OP...people here would be happy to help. We need actual numbers of what you’ve measured, not that they’re fine or good.
  47. Replies
    72
    Views
    3,744

    A meter is definitely one of the most essential...

    A meter is definitely one of the most essential tools on a service call. Don’t touch anything until you’ve confirmed your suspicions with your meter.
  48. Replies
    72
    Views
    3,744

    Blasphemy! That’s what small allen wrenches are...

    Blasphemy! That’s what small allen wrenches are for :grin2:
  49. Replies
    101
    Views
    3,247

    Weird, I never heard of getting paid by the call....

    Weird, I never heard of getting paid by the call. That sounds terrible. What’s the pay for a no heat? Do you pay for and mark up parts, or does the employer?
  50. Replies
    15
    Views
    686

    How careful were you brazing in the reversing...

    How careful were you brazing in the reversing valve? I’ve only seen a stuck reversing valve once. The pressures weren’t quite equal, they were 10-20# apart. I’ve seen plenty of bad compressors with...