Search:

Type: Posts; User: lkapigian

Page 1 of 20 1 2 3 4

Search: Search took 0.07 seconds.

  1. Sounds like you have it configured for dual fuel,...

    Sounds like you have it configured for dual fuel, should call for strip heat based upon how far away from set point
  2. it is in Smart Recovery Mode to be @ set point @...

    it is in Smart Recovery Mode to be @ set point @ the desired time ( not just starting at set time) it is a comfort feature, if you do not want that, you can disable it

    radical setbacks are not...
  3. Replies
    10
    Views
    301

    Hillary will jump in soon

    Hillary will jump in soon
  4. Thread: Motor RPM?

    by lkapigian
    Replies
    7
    Views
    400

    RPM = Hz* (2 / poles) * 60

    RPM = Hz* (2 / poles) * 60
  5. Why don't the Dems just let their vote speak...

    Why don't the Dems just let their vote speak then? They have screamed impeach since the day he took office.....................I'll eat crow if he does not win in 2020, but I am putting my money on...
  6. Trump will prevail, dems want to keep it behind...

    Trump will prevail, dems want to keep it behind closed doors so the public cant see Republicans want this to go to court so the public can see...........dems really don't want to get grilled under...
  7. Loved the ABC video allegedly depicting gnn...

    Loved the ABC video allegedly depicting gnn fights in Syria and was actually an old video from a gun range in kentucky in 2016............nothing fake about that
  8. we use filter grills so we can install multiple...

    we use filter grills so we can install multiple filters , not a big fan of 1 filter on the side of an AH, smallest single filter we install is 20x30
  9. unit size? I would not put (1) 20x20x4 on...

    unit size? I would not put (1) 20x20x4 on anything larger than a 2 ton, we do multiple 4"
  10. Replies
    16
    Views
    1,068

    I have had luck with it albeit the leak will come...

    I have had luck with it albeit the leak will come back, I can maybe extend an evap coil leak for the season but rest assured it will be back

    If it not done 100% correctly you will do mare damage...
  11. Ha Ha....I know

    Ha Ha....I know
  12. Replies
    7
    Views
    514

    ^^^^^^^^^^^^^^^This ^^^^^^^^^^^^^^^

    ^^^^^^^^^^^^^^^This ^^^^^^^^^^^^^^^
  13. IF the coil was out of warranty , this is why we...

    IF the coil was out of warranty , this is why we recommend replacing not just the coil for this very reason......That is of course assuming the coil was changed in a proper manner...fan barley...
  14. most are 1 year parts 5 compressor

    most are 1 year parts 5 compressor
  15. Replies
    2
    Views
    277

    External driers should always be installed, the...

    External driers should always be installed, the internal drier is Not a replacement or "in lieu of" an external drier...they would be OK if the install is Pristine and Sanitary ( regarding piping...
  16. Replies
    3
    Views
    189

    pretty much a hack install, and you should never...

    pretty much a hack install, and you should never "blank Off" especially if that fan discharges where the blank off is

    I imagine there are other issues but we would need to know static and airflow...
  17. Replies
    225
    Views
    4,668

    I can say I have been around it for 40 years and...

    I can say I have been around it for 40 years and in my observations have only seen some really good recipe's and cooks come from it
  18. Replies
    12
    Views
    542

    Developers want to pad the bottom line,...

    Developers want to pad the bottom line, theirs......

    you can always shop it both ways and not go one route only based upon an assumption

    spend it upfront or pay it in the end with headaches
  19. Replies
    12
    Views
    542

    Cant discuss pricing , but I am frequently more...

    Cant discuss pricing , but I am frequently more than a union shop

    Pricing is not always an indicator,but you can usually bet that when someone is the fraction the cost of another, they have left...
  20. Replies
    12
    Views
    542

    You can expect union work to be top notch all the...

    You can expect union work to be top notch all the way, you typically don't see hack work, that being said ( as an ex union fitter) our non union work parallels what you will see in a union shop
    ...
  21. Replies
    225
    Views
    4,668

    Coincidence maybe, but if overtime smoking dope...

    Coincidence maybe, but if overtime smoking dope leads you to do this, I hardly think that occured to these young shooters so quickly

    They were/are nuts to begin with..........I imagine you can say...
  22. Replies
    225
    Views
    4,668

    I'm sorry , the only thing weed leads to is...

    I'm sorry , the only thing weed leads to is overeating

    That being said there are tweekers that smoke dope, but you will not find an aggressive pothead
  23. non oem motor, we wont do that..but if the RPM...

    non oem motor, we wont do that..but if the RPM and all dimensions are correct it will function
  24. You need pro status to post a reply to a thread...

    You need pro status to post a reply to a thread other than one you started in AOP
  25. Replies
    28
    Views
    2,923

    We stay away from GD’s and go owner direct, put...

    We stay away from GD’s and go owner direct, put that extra % with us
  26. Replies
    57
    Views
    2,939

    I'll send you some pictures when I get back to...

    I'll send you some pictures when I get back to town Tuesday
  27. Replies
    57
    Views
    2,939

    Oversize them and the effect is negligible, I've...

    Oversize them and the effect is negligible, I've had these on for 20 years
  28. Replies
    57
    Views
    2,939

    I can get one but just custom made screens from a...

    I can get one but just custom made screens from a screen shop
  29. Replies
    9
    Views
    323

    There should not be much of a load , r13...

    There should not be much of a load , r13 partition which is treated as a North exposure and a ceiling if single story ....wold be no where near 5 tons
  30. Replies
    57
    Views
    2,939

    We take care of a cotton facility, we install...

    We take care of a cotton facility, we install mesh screens on the air cooled condensers with spare sets the maintenance staff cleans every few weeks like a lint screen on a drier
  31. Replies
    9
    Views
    323

    If an apartment hall, the walls are treated as...

    If an apartment hall, the walls are treated as partition , not interior as you have to assume vacancies and the space may become unconditioned
  32. Our Carrier Supplier, Sigler, was the last living...

    Our Carrier Supplier, Sigler, was the last living Carrier dealer to have worked with Willis Carrier. Russel past a couple years ago in his late 90s but worked at his Carrier dealership daily...I was...
  33. Replies
    5
    Views
    368

    you can go smaller outside bigger inside but not...

    you can go smaller outside bigger inside but not visa versa
  34. Replies
    22
    Views
    1,421

    High SC and SH usually indicates a restriction

    High SC and SH usually indicates a restriction
  35. We have our supplier and they have their own tech...

    We have our supplier and they have their own tech people that work with Carrier Directly and they do make visits to the home UNDER the 100% Satisfaction Program IF your contractor is part of that
  36. Thread: My Wife :-)

    by lkapigian
    Replies
    12
    Views
    1,660

    Ouch

    Ouch
  37. but his cooling IDB is 72, should be 75

    but his cooling IDB is 72, should be 75
  38. Replies
    4
    Views
    241

    If you have the liquidity, get a air handler for...

    If you have the liquidity, get a air handler for the roof,it will likely have to be special made/ordered

    In Ca where I am we are heavy into SPP ( though I prefer spilt's ) Noise and weight are...
  39. Not a big deal with the lower design on heating,...

    Not a big deal with the lower design on heating, I am a stickler on cooling ..........Contractor A report gives me a headache looking @:cheers:
  40. Thread: High Static

    by lkapigian
    Replies
    2
    Views
    252

    if you are reading it correctly, personally I...

    if you are reading it correctly, personally I would not worry about .67
  41. Replies
    4
    Views
    241

    They are available, but I would still go SPP

    They are available, but I would still go SPP
  42. If ducts are in the attic Contractor B is going...

    If ducts are in the attic Contractor B is going to be way off on second floor, negligible on the first but still off on the first
  43. Contractor B used the correct Indoor design, not...

    Contractor B used the correct Indoor design, not knowing what your city id 1% can vary , looks like B chose Boston AP are you close to that?

    I see 0 duct load, are they in a conditioned space? 0...
  44. dehumid or ventilation setting

    dehumid or ventilation setting
  45. Post the complete reports .dont game Manual J

    Post the complete reports .dont game Manual J
  46. cant discuss prices but if it is an old unit 20+...

    cant discuss prices but if it is an old unit 20+ probably didn't matter other than they should have looked indoors for a leak...we don't charge by the pound but rather a flat rate
  47. Replies
    11
    Views
    464

    I agree, we'd put it in and return also there is...

    I agree, we'd put it in and return also there is the option of making a smaller or larger one out of 2 or more capacitors, to many techs just don't know how.............
  48. first contractor used wrong cooling design , no...

    first contractor used wrong cooling design , no idea about 3- would be nice to see the full report
  49. Replies
    11
    Views
    464

    lots of things are done all the time that are...

    lots of things are done all the time that are incorrect....40% over is pretty significant
  50. Replies
    11
    Views
    464

    5% + on capacitance is ok voltage over is fine no...

    5% + on capacitance is ok voltage over is fine no matter, if it were me, i'd go back with the right size MFD