  1. Is this a new house? If so you may have to deal...

    Is this a new house? If so you may have to deal with the General Contractor or builder first? Is this a existing house? are permits required for this job? If so see if this crack HVAC Contractor took...
  2. Possible the basement stat is just suppose to be ...

    Possible the basement stat is just suppose to be a slave stat meaning it only works to open and close the zone once the main stat upstairs energizes the heat or cool. Seems like it does not do that....
  3. Is that a general question or did you purchase a...

    Is that a general question or did you purchase a Goodman Heat Pump online and going to tackle the project yourself....
  4. Have you used it since? Sure it didn't rupture a...

    Have you used it since? Sure it didn't rupture a refrigerant line and you blew the oil and refrigerant charge in your direction?
  5. Replies
    52
    Views
    1,042

    Board may have been changed as it seems the RV...

    Board may have been changed as it seems the RV coil was never energized in cool? as you mentioned for clarification " RV was not powered "

    Possible reason the RV labor is significantly less than...
  6. Replies
    52
    Views
    1,042

    :cheers: yes! So true

    :cheers: yes! So true
  7. Replies
    52
    Views
    1,042

    [QUOTE=TimmyJ;25733244]No, sorry it was a bad...

    [QUOTE=TimmyJ;25733244]No, sorry it was a bad joke. I just meant my washer/clothes dryer. I'll have to look into this to find out more.

    I did find out the tech is coming back out to replace the...
  8. The GC and the HVAC Contractors gears in their...

    The GC and the HVAC Contractors gears in their head are turning after you gave the GC the manual. Keep us posted...

    If they are out there,...would like to see the AHRI numbers for your two systems...
  9. Replies
    52
    Views
    1,042

    Translate "RV is not powered" means your in heat...

    Translate "RV is not powered" means your in heat mode meaning if one gauges is installed on the liquid line and the other on the insulated larger vapor line of the lineset your pressures will read...
  10. Replies
    52
    Views
    1,042

    So basically you have two driers on your system?...

    So basically you have two driers on your system? You can look inside the OD unit and see if the factory original is still there. Not to be confused with a discharge muffler which the SSZ may have....
  11. Replies
    52
    Views
    1,042

    Compressor and board replaced so far? Didn't they...

    Compressor and board replaced so far? Didn't they remove the factory drier that Goodman installs inside the OD unit? That also should have been removed, and a new bi-flow drier should have been...
  12. Replies
    52
    Views
    1,042

    What does the " detailed legible " ( probably...

    What does the " detailed legible " ( probably asking a lot in those two last words ) original invoice say in regards to what the Tech. found wrong with the compressor, as an example compressor not...
  13. Replies
    10
    Views
    210

    .

    .
  14. Replies
    10
    Views
    210

    It's a non match, Nordyne OD unit to Goodman Air...

    It's a non match, Nordyne OD unit to Goodman Air Handler, but if it cools that's great! May want to see if compressor sweats completely thou, as the whole compressor should not sweat.
  15. After rereading your initial post, if your...

    After rereading your initial post, if your slightly over the magic 79' I would lean on just the inverted loop by the indoor coil and what the recommended lineset that the install guide suggested. For...
  16. https://www.alpinehomeair.com/related/Common_Mista...

    https://www.alpinehomeair.com/related/Common_Mistakes_AC_Rev_41509.pdf

    Page 1 discusses the reasoning for those parts. I suppose if you want a better chance of a longer life compressor may want to...
  17. Here's what was found, I don't see where you...

    Here's what was found, I don't see where you reference 60,000/3 ton to me it's a general guideline. Just says anything over 80' lineset. Dated 2012 I'm sure it's still current.

    Says to install a...
  18. https://www.alpinehomeair.com/related/IO-258T.pdf...

    https://www.alpinehomeair.com/related/IO-258T.pdf

    Dated 2017-2018 says to contact distributor or use manual page 3 also shows a inverted loop to be installed if Air Handler is higher than OD unit...
  19. Replies
    10
    Views
    406

    Used the GSX14 install guide, OD temperature...

    Used the GSX14 install guide, OD temperature needs to be a minimum of 60 degree. If TXV is non adjustable use SC ONLY. Says around 7-9 Degree subcooling.
    ...
  20. Goodman web-site shows the GMSS furnace as "...

    Goodman web-site shows the GMSS furnace as " limited inventory ", probably due to having a PSC motor, and as of 3 July 2019 they ( manufacturers ) will not be producing furnaces with those types of...
  21. Replies
    8
    Views
    281

    Any rebates offered by your utility company as...

    Any rebates offered by your utility company as all those mentioned probably would apply. Need a AHRI number thou proving they installed matching equipment.
  22. Replies
    13
    Views
    299

    :cheers:

    :cheers:
  23. Replies
    13
    Views
    299

    Another option is to install a uncased Rheem/Rudd...

    Another option is to install a uncased Rheem/Rudd R410A coil or if the UHLL is the same size get the number for that model coil and remove the 12 year old R22 coil and slide in the new R410A coil, ...
  24. If it's a low SEER unit...why do you have to use...

    If it's a low SEER unit...why do you have to use a TXV if it's easily removal/install and not a simple troublefree piston metering device as another option?

    Send a picture of your coil and...
  25. Granted the Bosch may operate at lower OD...

    Granted the Bosch may operate at lower OD temperature but I'd be curious ( never having installed one ) at those temperatures how long is the defrost period lasts or even the frequency? As mentioned...
  26. Meant to say if Bosch requires or recommends any...

    Meant to say if Bosch requires or recommends any training on their equipment on proper install and set up and final field refrigerant set up.
  27. https://www.ahridirectory.org/Home/Download?Refere...

    https://www.ahridirectory.org/Home/Download?ReferenceId=sUzbLVC3/aFB9wkj0dGAH6S7n8m3sBX2KW9XVomczLng/0TYEl7Dcv1vQ1BIA1JD

    Here's your AHRI certified reference number proving a match for the...
  28. That would depend on if the metering device is...

    That would depend on if the metering device is brazed in or bolted in.
  29. Replies
    44
    Views
    1,249

    East meets West?

    East meets West?
  30. Here's your Active AHRI certified reference...

    Here's your Active AHRI certified reference number to prove at least the Carrier bid is matched and shows you the SEER and EER numbers. The partial model number ( for OD unit ) you gave would need...
  31. Replies
    44
    Views
    1,249

    Sorry here's one if you have a Heat Pump, the...

    Sorry here's one if you have a Heat Pump, the others given where straight A/C OD units..
    ...
  32. Replies
    44
    Views
    1,249

    Looks like that Air Handler has a ECM motor so if...

    Looks like that Air Handler has a ECM motor so if you wanted to go to 16 SEER as an example only, here is but one match as an example using the same brand for the OD unit, if you have rebates this...
  33. Guessing your furnace is 17" wide? As the Carrier...

    Guessing your furnace is 17" wide? As the Carrier bid shows a 17" wide coil. Depending what the total model number is on the OD unit this could be your AHRI number.
    ...
  34. You get the base warranty of 5 years on that...

    You get the base warranty of 5 years on that Ameristar if you don't register it, once you register it you get 10 years to original owner.

    10-Year Registered Limited Parts Warranty

    Registered...
  35. Replies
    44
    Views
    1,249

    Overwhelmed with all the quality answers?...

    Overwhelmed with all the quality answers? :whistle:
  36. So basically out of 3 systems only one leak? The...

    So basically out of 3 systems only one leak? The 1st place would be to check is the indoor coil if you call someone or do a visual of the OD unit, lineset to see if there is any residual oil around...
  37. ...what did they use to determine you have...

    ...what did they use to determine you have leaking systems? If you indeed having leaking units, how do they run, do they cool? A electronic leak detector or soap suds. Typically they use electronic...
  38. Replies
    44
    Views
    1,249

    Hello??...Got those number that where requested...

    Hello??...Got those number that where requested in post 4?
  39. I would not accept coil leaking in any of your...

    I would not accept coil leaking in any of your systems, until they can show you using soap suds only. Major leaks you'll see bubbles, tiny leaks the tendency is the leak will look like Barbasol...
  40. Replies
    44
    Views
    1,249

    " Newish 1-speed ICP air handler"....sounds like...

    " Newish 1-speed ICP air handler"....sounds like you have PSC motor? If so your probably better off with the 14 SEER, probably easier to match. Usually motors are multi speed, yours is set at one of...
  41. Dated 2019 ...

    Dated 2019

    http://www.guardianhomecomfort.com/equipment/guardian-gaw-systems.aspx
  42. Go to Mitsubishi web-site model number it shows...

    Go to Mitsubishi web-site model number it shows all the compatible ID models and SEER and EER of that combo. So 1st thing is to see if the ID section is compatible then if so check the overall...
  43. What does the OD unit brand model say on the...

    What does the OD unit brand model say on the web-site, chances it will say " up to "

    As an example multi zone

    https://daikincomfort.com/products/heating-cooling/multi-zone

    Outdoor units
  44. Replies
    6
    Views
    264

    Get another opinion, could be drain line plugged,...

    Get another opinion, could be drain line plugged, or leaking from PVC fittings/connection. You circled the primary PVC drain tube outside of the coil, which looks slightly misaligned, maybe it's...
  45. See that's what happens when the Contractor is...

    See that's what happens when the Contractor is dealing with a informed homeowner who asks quality questions.

    If it was not mentioned already, ask them for the commissioning report that they are...
  46. Alternate could mean you lose a slight percentage...

    Alternate could mean you lose a slight percentage in efficiency. Not enough to worry about...
  47. Does it run any quieter if the door is left open?...

    Does it run any quieter if the door is left open? Looks like a bare bone ( noisy ? ) Air Handler by the unpainted frame. Air Handlers have multispeed blower motors. They may have the blower set at a...
  48. Replies
    5
    Views
    203

    May need balancing dampers or a main damper...

    May need balancing dampers or a main damper installed if you don't already have them? See if you have something. They typically install balancing dampers at all branch lines ( right at the main duct...
  49. Make sure you register your unit for the full...

    Make sure you register your unit for the full manufacturer warranty, you should be getting at least a one year labor warranty.

    This may asking for to much but ask the Installing Contractor/builder...
  50. Make sure you register the Air Handler, you may...

    Make sure you register the Air Handler, you may get upwards of 10 years warranty even thou the OD section was not changed at the same time.