Search:

Type: Posts; User: pecmsg

Page 1 of 20 1 2 3 4

Search: Search took 0.28 seconds.

  1. Adding N2 to the remaining charge for leak...

    Adding N2 to the remaining charge for leak checking is Illegal. (Good Luck with that. Inform your local DEC / EPA if you want)

    Pressurizing the system with 5PSIG of R-22 and following with N@ is...
  2. Replies
    18
    Views
    331

    Squirrel cage fans AKA centrifugal fans "Throw...

    Squirrel cage fans AKA centrifugal fans "Throw the air"! if you restrict the inlet or outlet the wheel just spins, less work is being done, less air is being moved so less amperage or electrical is...
  3. Replies
    11
    Views
    326

    This is the best statement I've seen in a while!...

    This is the best statement I've seen in a while!

    Your going to go far in this industry! :cheers:
  4. Replies
    11
    Views
    160

    Sucks getting old!

    Sucks getting old!
  5. Replies
    18
    Views
    331

    Sorry to say that restricting the air flow...

    Sorry to say that restricting the air flow actually lowers the power consumption (AKA Amperage) of the blower motor, so in your case I feel the motor and or capacitor were already doomed the filter...
  6. Replies
    2
    Views
    147

    I wonder about the warranty with being out of...

    I wonder about the warranty with being out of level!
  7. Replies
    7
    Views
    129

    So your changing a perfectly good compressor? ...

    So your changing a perfectly good compressor?

    With POE make room for a suction filter.
  8. Tell the management company to pay someone to...

    Tell the management company to pay someone to hook it up!

    You shouldnít accept the responsibility in any shape or form!
  9. Replies
    7
    Views
    129

    Evap and compressor. Why did the compressor...

    Evap and compressor.

    Why did the compressor fail?

    Change the whole unit youíve got a 12 year old water cooled condenser that will probably fail sooner then later!
  10. Nest is POO

    Nest is POO
  11. Replies
    13
    Views
    284

    I got off them early. Helps having a Daughter...

    I got off them early.

    Helps having a Daughter with a medical degree!

    My issue was the pain meds, 100 hits of oxy for 30 days with 2 refills. Wonder why thereís a opioid problem!
  12. Find a different service provider!

    Find a different service provider!
  13. Replies
    10
    Views
    295

    Do you realize how lucky you are extra wires were...

    Do you realize how lucky you are extra wires were pulled!
  14. When those ducts were first sized the equipment...

    When those ducts were first sized the equipment was a low velocity high temperature system. Todayís equipment is higher velocity lower temperatures.
    The two really donít work well together.
  15. Replies
    13
    Views
    312

    FWIW Mr Bill Itís a nation wide problem!

    FWIW Mr Bill

    Itís a nation wide problem!
  16. Replies
    13
    Views
    284

    It will be 8 years in Feb since my Quadruple. ...

    It will be 8 years in Feb since my Quadruple.

    Take it real easy on the pain meds and Listen to the physical therapist, Get that mussel mass back that's the fastest and best way to recover.
    ...
  17. I personally don't have a problem with Dye if...

    I personally don't have a problem with Dye if done properly, Obviously in this case it was not. Dump the oil and change it. This will also deal with any possible moisture issues!

    As far as the 3...
  18. You really donít want to hear what I have to say!

    You really donít want to hear what I have to say!
  19. Keep searching on the net...... Increase your...

    Keep searching on the net......
    Increase your fire insurance and get a Low level CO detector!
  20. Replies
    1
    Views
    152

    Pull the charge and weigh it! Straighten out...

    Pull the charge and weigh it!

    Straighten out the kinks!
  21. Find a different tech!

    Find a different tech!
  22. Replies
    13
    Views
    312

    Unfortunately thatís the way it is. 50 - 75%...

    Unfortunately thatís the way it is.

    50 - 75% of the techs are not qualified or are sales techs.

    Once you find one take real good care of him / her!
  23. Replies
    17
    Views
    315

    In N O Dump the Carrier Get a 90+% furnace

    In N O
    Dump the Carrier

    Get a 90+% furnace
  24. They were having leak issues early on.

    They were having leak issues early on.
  25. How did you decide on 4-Tons? How many CFMís...

    How did you decide on 4-Tons?

    How many CFMís can the existing duct handle?
  26. Replies
    7
    Views
    192

    Get a mini split!

    Get a mini split!
  27. Replies
    7
    Views
    198

    and we have to do the same thing, check the...

    and we have to do the same thing, check the entire Low Voltage Circuit!
  28. Itís Crap!

    Itís Crap!
  29. Replies
    7
    Views
    198

    Everything in the low voltage circuit!

    Everything in the low voltage circuit!
  30. it sounds like the control is calling for whatís...

    it sounds like the control is calling for whatís needed!
  31. Replies
    4
    Views
    242

    At design conditions yes it will run all the...

    At design conditions yes it will run all the time. Unless the unit was sized for cooling I would expect a few cycles overnight at 32*F
  32. Once you perform a manual ďJĒ and find out...

    Once you perform a manual ďJĒ and find out exactly how many BYUís the home looses then Youíll need a manual ďDĒ to see if the ducts can in fact handle the required air flow.
  33. Replies
    3
    Views
    232

    A replacement is available. You're wholesaler...

    A replacement is available. You're wholesaler will know the new model #!
  34. BS Properly sized and installed equipment...

    BS

    Properly sized and installed equipment doesnít need seasonal charge adjustments.

    The only way to check the charge in heat mode is to pull it and weigh it. Iím sure he didnít do that!
  35. If the max is 15 then thatís it. Sparky should...

    If the max is 15 then thatís it. Sparky should know that!
  36. Replies
    13
    Views
    492

    Ductless systems use inverter driven compressors....

    Ductless systems use inverter driven compressors. Still not much heat is available at 0*F
  37. Replies
    5
    Views
    163

    http://www.ua.org/apprenticeship Get paid to...

    http://www.ua.org/apprenticeship

    Get paid to learn
    Learn the right way
  38. Replies
    10
    Views
    214

    You need to call for service.

    You need to call for service.
  39. Replies
    33
    Views
    784

    Please be advised, over 1/2 of the alleged techs...

    Please be advised, over 1/2 of the alleged techs out there are NOT techs but salesmen.

    Take pics
    Ask questions

    Do Not Believe what they say, Question, Question, Question!
  40. Replies
    4
    Views
    148

    Bad evaporator

    Bad evaporator
  41. Replies
    4
    Views
    209

    Sounds like the tech is guessing. Did he test the...

    Sounds like the tech is guessing. Did he test the pressure at the switch or just change it?

    Insider at 14amps I donít believe
  42. Thread: She blew up

    by pecmsg
    Replies
    7
    Views
    484

    So did I and they accepted! If you can get a...

    So did I and they accepted!

    If you can get a cold pot, saves a lot of oil changes in the vacuum pump.

    I also went thru 5 or 6 large N2 bottles. Vineyard supplied and just bled N2 between pump...
  43. Replies
    12
    Views
    395

    Why is it orange?

    Why is it orange?
  44. Thread: She blew up

    by pecmsg
    Replies
    7
    Views
    484

    Im on day 8 (a few hours a day) of a 15-Ton...

    Im on day 8 (a few hours a day) of a 15-Ton chiller. Just starting to get below 1000 microns.
  45. Thread: sight glass ..

    by pecmsg
    Replies
    2
    Views
    210

    Could just be a bad indicator, overheated...…….....

    Could just be a bad indicator, overheated...……..

    If new id get another in warranty.
  46. Replies
    8
    Views
    328

    What does your service provider say?

    What does your service provider say?
  47. No Load...….. the electrical energy will...

    No Load...…..

    the electrical energy will produce more heat and less work.

    Add to that the extra starting torque will tear that squirrel cage to bits!
  48. What's there warranty policy for on line sales?

    What's there warranty policy for on line sales?
  49. Replies
    33
    Views
    784

    and maybe a 3rd

    and maybe a 3rd
  50. Replies
    33
    Views
    784

    Iíll get in trouble for the second time today ...

    Iíll get in trouble for the second time today


    BS!
Results 1 to 50 of 1000