Search:

Type: Posts; User: AIRCON8

Page 1 of 6 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    9
    Views
    552

    its probably a short check the thermostat if is...

    its probably a short
    check the thermostat if is old sometime can create a short
    or could be thermostat wire with broken insulation touching metal or another wire
    sometimes contactor coil is...
  2. Replies
    52
    Views
    16,370

    can you check blower and condenser motor with 902...

    can you check blower and condenser motor with 902 ?
    i mean winding to ground ?
    i have a friend of mine that said he need a DMM to do that
  3. Replies
    14
    Views
    570

    i also use the model 1F85U-22NP non...

    i also use the model 1F85U-22NP non programmable. screen is 5" instead of 4.5. nice one
  4. Replies
    14
    Views
    570

    [QUOTE=EnergyOasis;25838860]I like the looks of...

    [QUOTE=EnergyOasis;25838860]I like the looks of Emerson 80 for homeowners on a budget. Would you opt for the programmable style for truck stock or no?

    Never tried the programmable, just the 1h1c...
  5. Replies
    14
    Views
    570

    i like the T4 and the Emerson series 80 The last...

    i like the T4 and the Emerson series 80
    The last one is for when i replace stat for property managers, cheap and so far no issues
  6. no need to make more money lying to the customer.

    no need to make more money lying to the customer.
  7. Not correct, R410A is a blend of 2 refrigerants,...

    Not correct, R410A is a blend of 2 refrigerants, R32 and R125, i believe 50-50 %, R 32 is inflammable so they added R125 to keep the inflammable level very low, but, when you have a leak, you don't...
  8. Replies
    101
    Views
    4,110

    Thats what i do but we raise the pressure at 250...

    Thats what i do but we raise the pressure at 250 and use H10 PRO for eventual leak search LOL

    Great mind think a like
  9. Replies
    101
    Views
    4,110

    i keep pressurize at 250 psi LOL

    i keep pressurize at 250 psi LOL
  10. Replies
    101
    Views
    4,110

    LOL not needed 600 psi for a 2 ton LOL

    LOL
    not needed 600 psi for a 2 ton LOL
  11. Replies
    101
    Views
    4,110

    So according to Bosch i was 150 PSI over :bump:...

    So according to Bosch i was 150 PSI over :bump:
    not gonna change my mind, 250 psi
    period :whistle:
  12. Replies
    101
    Views
    4,110

    now everybody talking about leak detector and,...

    now everybody talking about leak detector and, soon, they'll switch to tools LOL
  13. Thread: Gauges!

    by AIRCON8
    Replies
    26
    Views
    1,599

    i have the Testo i like them a lot i prefer test...

    i have the Testo i like them a lot
    i prefer test because not too big, FP a bulky and heavy
    only problem with theist is the temperature probe connector keep coming out
    quite annoying sometimes
  14. Replies
    101
    Views
    4,110

    well here another example that im right :cheers:

    well here another example that im right :cheers:
  15. Replies
    101
    Views
    4,110

    yes if someone is willing to learn

    yes if someone is willing to learn
  16. Replies
    101
    Views
    4,110

    well you can google it or you tube

    well you can google it or you tube
  17. Replies
    101
    Views
    4,110

    there you go :putergreet:

    there you go :putergreet:
  18. Replies
    101
    Views
    4,110

    triple vacuum

    triple vacuum
  19. Replies
    101
    Views
    4,110

    i agree. LOL Finally someone taking my side LOL...

    i agree. LOL
    Finally someone taking my side LOL
    yes i flow nitrogen when I'm brazing and yes i do 3 vacuum
    and again i don't install VRF with hundred of brazing, YOU have to do 2 brazing on...
  20. Replies
    101
    Views
    4,110

    exactly 250 and triple vacuum that's it

    exactly
    250 and triple vacuum
    that's it
  21. Replies
    101
    Views
    4,110

    Still not going there 250 psi its my limit...

    Still not going there
    250 psi its my limit period LOL
  22. Replies
    101
    Views
    4,110

    everybody talking about mini split and VRF can...

    everybody talking about mini split and VRF
    can you imagine 600 psi on a York micro channel coil ?
    they leak just if you look at them LOL
  23. Replies
    101
    Views
    4,110

    Nope i'm not going there period LOL 400 psi...

    Nope i'm not going there
    period LOL
    400 psi too much it will leak at 200 and with a good leak detector you'll find it.
  24. Replies
    18
    Views
    860

    Some of multi HP motors have very affordable...

    Some of multi HP motors have very affordable price right now
    almost the same price of a fractional hp
    ok they don't have ball bearing but if you replace the motor on an old system could be...
  25. Replies
    101
    Views
    4,110

    don't know i was just answering to a guy here

    don't know i was just answering to a guy here
  26. Replies
    101
    Views
    4,110

    i do residential up to 5 tons pressure switches...

    i do residential up to 5 tons
    pressure switches txv coils and compressor valve
    no need to go to 600 psi
    not me
  27. Replies
    101
    Views
    4,110

    nope i'm not go that high LOL 250 is the limit...

    nope i'm not go that high LOL
    250 is the limit period
  28. Replies
    18
    Views
    860

    i found Packard a good brand i also buy...

    i found Packard a good brand
    i also buy contractor and transformer from them
  29. Replies
    7
    Views
    680

    thank you for your info

    thank you for your info
  30. Replies
    21
    Views
    2,019

    Klein the blue one with curved handle

    Klein
    the blue one with curved handle
  31. Replies
    340
    Views
    165,596

    Sticky: Poll: Trane is my first choice Bryant second one...

    Trane is my first choice
    Bryant second one
    Rheem for property management companies
    at least until Rheem will continue to make a/h with PSC motor and capacitor LOL
  32. Replies
    101
    Views
    4,110

    i also open bot gauges all the way and let the...

    i also open bot gauges all the way and let the nitrogen flow in slowly, but not going up to 400 PSI
    i stop at 250 :)
  33. Replies
    242
    Views
    12,979

    i am currently installing T4 and they are not too...

    i am currently installing T4 and they are not too bad.
    i have purchased a couple of White Rogers/ Emerson. Series 80 i guess
    so far so good
    i just can't decide LOL
  34. Replies
    18
    Views
    860

    i am working for some property managers so i keep...

    i am working for some property managers so i keep some multi HP on my truck, 3 x 1075 and 2 x 825, i can replace the motor right there, no need to go back to supplier. For parts in warranty, i...
  35. Replies
    18
    Views
    860

    TRUCK STOCK CONDENSER MOTOR

    What do you carry on your truck
    Multi HP, more expensive but one get it all ( almost)
    or less expensive fixed fractional HP but you need lot of them ?
  36. Replies
    34
    Views
    2,360

    What if it will stop work to get a replacement...

    What if it will stop work to get a replacement one will be a mess, plus have to wait few days for delivery
  37. Replies
    34
    Views
    2,360

    Never tried that one

    Never tried that one
  38. Replies
    34
    Views
    2,360

    Yeah i heard about that issues :gah:

    Yeah i heard about that issues :gah:
  39. Replies
    34
    Views
    2,360

    i also like the GLAS from Johnston Controls, its...

    i also like the GLAS from Johnston Controls, its amazing, but don't know anything about it and it's reliability.
  40. Replies
    34
    Views
    2,360

    The TH 8321 is the one i always installed, and so...

    The TH 8321 is the one i always installed, and so far i had no call back. i was looking for alternatives.
    the system was a Trane 16 SEER not communicating. i ended up installing the Pro 8000 because...
  41. Replies
    34
    Views
    2,360

    Just purchased a couple of WR too but not wifi...

    Just purchased a couple of WR too but not wifi
    hopefully i won't regret it
  42. Replies
    34
    Views
    2,360

    i like it a lot, but here in FL its more then $...

    i like it a lot, but here in FL its more then $ and the final price to the customer is going to be very high
  43. Replies
    34
    Views
    2,360

    which one do you use ? the touchscreen or the...

    which one do you use ? the touchscreen or the other one ?
  44. Replies
    34
    Views
    2,360

    is pro 9000 alexa google play and apple home kit...

    is pro 9000 alexa google play and apple home kit ready ?
  45. Replies
    34
    Views
    2,360

    SENSI touchscreen look nice

    SENSI touchscreen look nice
  46. Replies
    34
    Views
    2,360

    anyone ever installed the GLAS from Johnson...

    anyone ever installed the GLAS from Johnson controls ??
  47. Replies
    34
    Views
    2,360

    i like the PRO9000 this is the one I'm thinking...

    i like the PRO9000 this is the one I'm thinking about if i will never stop installing the vision pro.
  48. Replies
    34
    Views
    2,360

    I'm not crazy about Ecobee sorry :whistle:

    I'm not crazy about Ecobee sorry :whistle:
  49. Replies
    34
    Views
    2,360

    WHICH WIFI THERMOSTAT DO YOU INSTALL ???

    I NEED TO INSTALL A WIFI TSTAT FOR A CUSTOMER
    I ALWAYS INSTALL HONEYWELL VISION PRO
    BUT I'M LOOKING FOR ALTERNATIVES
    I WAS WONDERING WHAT DO YOU GUYS INSTALL
  50. Replies
    242
    Views
    12,979

    i just purchased a couple of Emerson/white rogers...

    i just purchased a couple of Emerson/white rogers T80 2h1c and 1h1c
    wanna give them a try, what do you think about them ?
Results 1 to 50 of 288