  1. Thread: Carrier Doas

    by Balibe
    Replies
    6
    Views
    442

    OEMCtrl devices cannot be uploaded into i-Vu...

    OEMCtrl devices cannot be uploaded into i-Vu without a Permission Key from the manufacture. They will need the Permissions ID from the i-Vu so they can generate a key. The ID and keys are added in...
  2. Replies
    7
    Views
    529

    It was a branded R2 Jace. I have only installed...

    It was a branded R2 Jace. I have only installed one, it was back in 2004/2005. It was not used as the front-end, it was used to integrate a bacnet system to CCN for control. ComfortView was the...
  3. Replies
    7
    Views
    529

    You will not be able to force the schedule you...

    You will not be able to force the schedule you see and have it effect the schedule table in the CCN device like you have done with ALC devices. The schedule table in the CCN device is what it follows...
  4. Thread: Comfortview

    by Balibe
    Replies
    13
    Views
    721

    Check the latest Master Price Sheet, effective...

    Check the latest Master Price Sheet, effective 01/2019 ..... still available.



    It was discussed at the Controls Expert Expo this past May, they need to keep the mouse happy ......
  5. Replies
    11
    Views
    450

    The IP controllers do not currently support...

    The IP controllers do not currently support static IP address configuration. Therefore these devices must be dynamically assigned IP addresses by the IT DHCP server. If you haven't seen it yet, look...
  6. Thread: Comfortview

    by Balibe
    Replies
    13
    Views
    721

    It is still supported and for sale. They are in...

    It is still supported and for sale. They are in the process of updating it for Windows 10.

    The original comfort controllers (1600/6400) are no longer available. There is a updated 6400 to replace...
  7. Max is correct on the format for adding to the...

    Max is correct on the format for adding to the current logic, the issue is with Carrier. They lock the RTU-Open logic so it can not be modified to add additional points. Another downfall is this...
  8. Anytime ..... in addition to the driver...

    Anytime ..... in addition to the driver properties, it is also available from the installers page .............
    .
    810541
  9. i-Vu has show bindings ...... under installer,...

    i-Vu has show bindings ...... under installer, select the network device then properties .....



    DEV:160024 --> 1600:192.168.10.40:47808 CCN Link - Atrium P2 (#bacnetip/integrator_bridge65)...
  10. Replies
    10
    Views
    994

    Is this your message ................ ...

    Is this your message ................


    Starting discovery
    Binding to device 130003...
    Reading Object List (this may take a while)...
    No response from device: 8:130003 Error: No response from:...
  11. Thread: Wireless JACE

    by Balibe
    Replies
    9
    Views
    557

    It is a paid extra for one with the wireless...

    It is a paid extra for one with the wireless radio disabled. I have had an Army & Navy base that required the wireless function to be non-functional, not just disabled in the settings.
  12. Replies
    13
    Views
    2,462

    The PC6400 appears to be the same module as a...

    The PC6400 appears to be the same module as a Comfort Controller 6400. There is no program used to upgrade or change the software. The Prom Chip needs to be replaced.
  13. There was a management tool update/patch that was...

    There was a management tool update/patch that was issued to resolve browser issues. Takes the management tool to Ver C from shipped Ver A or Ver B. This was applied separately from service pack 1,...
  14. Replies
    16
    Views
    1,534

    Carrier does sell them, part number is TERM485...

    Carrier does sell them, part number is TERM485 (qty 26). They are a 120ohm resistors. We like them better as they are in hard plastic similar to heat sink.
  15. Replies
    12
    Views
    4,886

    No where in the "yup read above" does it mention...

    No where in the "yup read above" does it mention baud rate ..... maybe you are too smart for all of us and knows "and stuff" is baud rate!!

    Maybe next time you should read the post before your...
  16. Replies
    12
    Views
    4,886

    Did you check the baud rate? They default at...

    Did you check the baud rate? They default at 76,800. Connecting to the USB port is not the same as the mstp comm.
  17. Replies
    1
    Views
    1,218

    I typically use the device instance, there are...

    I typically use the device instance, there are other options. Have you read the BACnet integration guide for i-Vu? I should have been on the tech tools cd.

    The second network is for the non-open...
  18. Replies
    4
    Views
    3,730

    They are there, select FILES at the top, then ALL...

    They are there, select FILES at the top, then ALL FILES on the right. They are on the 1st page titled "FX-MSTP Controllers-Wiring 4_15_13".

    You do know they recently moved everything to a format....
  19. Replies
    11
    Views
    2,248

    AFAIK only the FX-16 can be uploaded. It was a...

    AFAIK only the FX-16 can be uploaded. It was a feature they added after the original release.
  20. It does not appear to matter if a conventional...

    It does not appear to matter if a conventional thermostat is used or a zone sensor. With conventional stat control, the unit should not need to know occupied/unoccupied as it will follow the stat...
  21. They changed control boards over the years. The...

    They changed control boards over the years. The older ones needed a CTI (Conventional Thermostat Interface) board. The newer Reliatel's can do both. So it depends on the unit and control package the...
  22. Replies
    30
    Views
    6,822

    There will need to be two (2) CCN address in the...

    There will need to be two (2) CCN address in the UPC.

    One is the CCN address of the RTU the UPC needs to talk to ..... Properties > Control Program > Status > CCN (default is 0,1). This should...
  23. Replies
    13
    Views
    3,283

    You will need a Lon adapter. I use the USB--->Lon...

    You will need a Lon adapter. I use the USB--->Lon adapter that was provided with my Trane Rover v7 Service Tool kit. It also did work with the PCMIA--->Lon adapter that I had with Rover v6.0
  24. Replies
    10
    Views
    4,395

    I am corrected :oops: The CIV-IM was used...

    I am corrected :oops:

    The CIV-IM was used with i-Vu v3.0. It is not used with versions v4.0, v5.0 or v6.0 that Carrier sold to independent contractors. How did you manage to get one? As...
  25. Replies
    13
    Views
    3,283

    Sounds like the programs in the controllers are...

    Sounds like the programs in the controllers are different. I would use NodeUtil to get the the xif out of the controller then create your own lnml. With the xif out out of the controller you will...
  26. Replies
    10
    Views
    4,395

    I doubt you have a CCN Integrator. What is the...

    I doubt you have a CCN Integrator. What is the part number of your device? AFAIK the CCN Integrators were Carrier only and used with i-Vu v3.0, which was also Carrier only. I think what you purchase...
  27. Replies
    9
    Views
    2,003

    Have to tried going back to Maxline through your...

    Have to tried going back to Maxline through your support channels?

    I had an issue last summer with their driver on a couple comm4 chillers. Once my local support channel put me in touch via email...
  28. Replies
    11
    Views
    5,856

    Sounds like you have everything correct. Are you...

    Sounds like you have everything correct. Are you seeing the Open devices in FA?

    The discovery will not populate the third-party devices with the Open devices. Even when they are wired to the same...
  29. Replies
    11
    Views
    5,856

    I assume you have i-Vu v6.0 as you are installing...

    I assume you have i-Vu v6.0 as you are installing the Carrier front-end?

    Are you using an OpenLink or CCNLink to integrate the BACnet units?

    What location under Installer are you attempting to...
  30. Replies
    4
    Views
    889

    Once the point is Network Visible, I typically...

    Once the point is Network Visible, I typically map a point with this typical address: exp:#eq_1619519_1 /dew_pt. This mapping is getting the dew point value from device #19 on network 16195. Another...
  31. Replies
    8
    Views
    2,968

    Try the link below. Scroll down the list, it...

    Try the link below. Scroll down the list, it should be the fourth download in the list. You will need a standard USB to Printer cable to connect to the device. This is the cable most newer USB...
  32. Replies
    10
    Views
    1,882

    Post the serial number with the model number. I...

    Post the serial number with the model number. I can lookup the unit easier with the serial number to see how it was shipped .....
  33. Replies
    25
    Views
    3,911

    Sounds like a broadcast acknowledger problem as...

    Sounds like a broadcast acknowledger problem as you are able attach to the device after getting the loading table and communications failure during the attach. Are you getting the loading table and...
  34. Replies
    25
    Views
    3,911

    Sounds like the system pilot security options,...

    Sounds like the system pilot security options, you can access just about everything with a system pilot that NSTV can access. Try the following ....

    The current security level can be overridden...
  35. Replies
    1
    Views
    801

    The basic lead/lag that Carrier offers in their...

    The basic lead/lag that Carrier offers in their PICS's are only for the chillers. They don't offer anything in the package units.

    Not sure which PIC's you have in the package units, but you will...
  36. Replies
    1
    Views
    1,360

    The UCM's should be Comm4 as the CCP is 1997. If...

    The UCM's should be Comm4 as the CCP is 1997. If you have Rover with Comm4 cable you can check. With the relay board in the VariTrac CCP, there should be no comm to the RTU.

    You should be able to...
  37. Replies
    3
    Views
    1,378

    SketchUp ???? (http://www.sketchup.com/) It is no...

    SketchUp ???? It is no longer owned by Google, Trimble Navigation bought it in 2013 .....
  38. Thread: Trane varitrac

    by Balibe
    Replies
    8
    Views
    2,637

    Contact your local Trane salesman for the...

    Contact your local Trane salesman for the VariTrac software and cable. All they have for download on their website is update v12sp6.

    If you have Rover, you can access the zone controllers but...
  39. Thread: Trane varitrac

    by Balibe
    Replies
    8
    Views
    2,637

    Version 6- uses HyperTerminal, beige panel cover...

    Version 6- uses HyperTerminal, beige panel cover with a 2 line lcd display. Version 10+ uses VariTrac software, white panel cover with touch screen.
  40. Thread: MCS CONTROLLS

    by Balibe
    Replies
    1
    Views
    751

    I have integrated a few of these controllers. The...

    I have integrated a few of these controllers. The ones I have dealt with have been programmed specifically for the chiller/scu it controls and not a generic program.

    I would call their tech...
  41. Replies
    40
    Views
    23,865

    FYI ..... Each software requires a separate key...

    FYI ..... Each software requires a separate key to use the software. The ComfortView Key will not work with NSTV and requires additional adapters. The NSTV USB Converter/Key will not work with...
  42. Replies
    3
    Views
    1,583

    Below are the LED indications, these are for the...

    Below are the LED indications, these are for the BACnet flavor. There does not seem to be a way to reset the card. Verify the 24vac, if someone switched the + and Com to the translator & chiller pic...
  43. Replies
    9
    Views
    3,526

    I also use comfortsite, the drawing is not there...

    I also use comfortsite, the drawing is not there in the elibrary or under the unit information. From the unit manuals, you have the correct drawing number. There were two units originally ordered,...
  44. Replies
    9
    Views
    3,526

    Post the serial number of the unit, it will be...

    Post the serial number of the unit, it will be easier to lookup with that versus the drawing number .....
  45. Replies
    4
    Views
    1,288

    A filter for displayname like *DPR* will show all...

    A filter for displayname like *DPR* will show all points with DPR in the name. Works good if you have several points like DPR_O_1, DPR_O_2, etc.

    There is also the option above the filter to narrow...
  46. Replies
    8
    Views
    1,620

    I have used the gateway linked below for comm4...

    I have used the gateway linked below for comm4 vav's, it has worked great with no issues for a couple years. I have not used it on anything else but comm4 vav's, but it states it also works with...
  47. I also like to use the SunPostion. If you need it...

    I also like to use the SunPostion. If you need it earlier/later, just add/subtract to the angle. Typically just a couple degrees
  48. Replies
    3
    Views
    1,011

    To reiterate mcquire07, the controller must be...

    To reiterate mcquire07, the controller must be off the network for the controller to reply it's address when scanned with 0,0. It is rare, but there a few devices that will not reply to 0,0 like...
  49. Replies
    3
    Views
    985

    It is a separate program, you will find it in the...

    It is a separate program, you will find it in the Programs\ComfortView folder with all the other shortcuts ....
  50. Replies
    12
    Views
    2,385

    You can globally broadcast a single point from a...

    You can globally broadcast a single point from a CC6400 only if the point name is the same in all controllers needing it and the point is writable. The fire shutdown (FSD) in Plinks is a network...