Search:

Type: Posts; User: Bazooka Joey

Page 1 of 20 1 2 3 4

Search: Search took 0.08 seconds.

  1. “ It's very confusing but Bosch seems to have the...

    “ It's very confusing but Bosch seems to have the best price even compared to entry level Goodmans and others that are considered base level 13-14 SEER single stage systems. So is this the best bang...
  2. Replies
    2
    Views
    82

    What does this Air Handler have for heat,...

    What does this Air Handler have for heat, electric heat strips, hooked to a Heat Pump? How old is the system? Have you ever had a basic PM check if your unit is more than a few years old?
  3. Replies
    50
    Views
    775

    Just my :.02: worth, ( watching the video you...

    Just my :.02: worth, ( watching the video you provided ) but I like to remove the factory drier and install a short piece of copper tubing to take the place of where the drier was removed, and...
  4. Replies
    50
    Views
    775

    Well...remember if this person says you have a...

    Well...remember if this person says you have a leak ( using a electronic ) tell him to prove the location with soap and have him show you the bubbles. If he says he does not have any, give him some...
  5. Replies
    50
    Views
    775

    “ Someone is coming out tomorrow. I will have him...

    “ Someone is coming out tomorrow. I will have him check for acid and find the leak. Hopefully the leak can be patched.”

    Did they come out? If so what was the prognosis? Doubt they “ patch “...
  6. Buying a extended labor warranty from the...

    Buying a extended labor warranty from the manufacturers to me anyway is better than purchasing one from the Contractor, as your stuck with them for the duration of the contract, and certainly the...
  7. Not 100% sure but I don’t believe Bosch offers a...

    Not 100% sure but I don’t believe Bosch offers a manufacturers extended labor warranty like pretty much everyone else.

    Make sure they quote a AHRI matched system to get a true SEER, HSPF ratings (...
  8. Replies
    5
    Views
    263

    Did the Tech. balk at starting your unit? ( I’m...

    Did the Tech. balk at starting your unit? ( I’m surprised you where able to get someone out on a job you installed and especially gas piped, and flue piping as that could be a liability for them as...
  9. Replies
    5
    Views
    263

    Do you have a one year labor warranty on this “...

    Do you have a one year labor warranty on this “ new “ furnace, even if it’s over the one year labor warranty, call out the Company/Contractor who installed it. If system was registered you have 10...
  10. Replies
    50
    Views
    775

    Here’s one kit for checking both acidic and...

    Here’s one kit for checking both acidic and moisture, doubt whoever you call will have one, but if your curious. Never used it myself, so I don’t know the accuracy.
    ...
  11. Replies
    50
    Views
    775

    If the color of the oil is slightly black it...

    If the color of the oil is slightly black it still may be acidic, the darker the color of the oil ( blackish ) the more acidic a system is. Hopefully they find proof positive what your problem is,...
  12. Replies
    50
    Views
    775

    Yes remove both driers, then install a new bi...

    Yes remove both driers, then install a new bi flow wherever the field one was installed. Hopefully they can find your leak, and not just by a electronic, but actually pin pointing it after the...
  13. Replies
    50
    Views
    775

    Post 21 address acid, there are other brands, yes...

    Post 21 address acid, there are other brands, yes it has a acidic smell, but has different levels of smell, if it a very strong acidic smell to me anyway compressor damage is likely.
  14. Replies
    50
    Views
    775

    https://www.qwik.com/products/qwik-check Have...

    https://www.qwik.com/products/qwik-check

    Have them check for acid in system, as the bigger problem is the compressor oil will breakdown and cause a burnout, and compressor failure. Moisture will...
  15. Replies
    50
    Views
    775

    If it was a bad drier, then they should have...

    If it was a bad drier, then they should have removed the original and installed a new bi flow by the Air Handler ( away from the elements ) don’t know what else to tell you, possible someone can...
  16. Replies
    50
    Views
    775

    Doubt drier is leaking ( the one they changed...

    Doubt drier is leaking ( the one they changed unless it’s a inferior braze job, or if it was soft solder maybe they overdid the solder and some got inside the tubing, closing it up a little ) how...
  17. Replies
    50
    Views
    775

    Where was the drier located that was changed? A...

    Where was the drier located that was changed? A field install one or the factory installed one?

    What was the OD temperatures when you where getting those pressures you posted.
  18. Replies
    9
    Views
    306

    You can drop that 40+ degree by 8 as you said the...

    You can drop that 40+ degree by 8 as you said the stat was reading 74 and the return was pulling in 82. Possibly the other reason would be your also have the electric heat running ( 2nd stage ) along...
  19. Replies
    9
    Views
    306

    Call the Installing Contractor back, as they...

    Call the Installing Contractor back, as they should have given you at least a one year labor warranty and discuss the return pulling in a good amount of supply air, so no that is not a normal. To me...
  20. Replies
    9
    Views
    306

    You bought the equipment and installed it? Do you...

    You bought the equipment and installed it? Do you have electric heat?

    Is this a packaged one piece system or a split system?

    What’s the reason to run system at 82 degree? for test purposes?...
  21. Replies
    4
    Views
    200

    At 10 SEER, hopefully whoever you call actually...

    At 10 SEER, hopefully whoever you call actually will try to save your system, and not automatically condemn it and try to sell you a new system.
  22. Replies
    2
    Views
    206

    The Amana has the better manufacturers warranty...

    The Amana has the better manufacturers warranty once registered and a stainless steel HX. You get a new furnace ( to original registered owner ) if HX ever fails on the Amana model you quoted. The...
  23. Whatever they charged you ( retail ) is what they...

    Whatever they charged you ( retail ) is what they owe you, ( plus parts tax ) on that part not what they paid for it ( wholesale LENNOX PRESSURE SWITCH )
  24. Guessing your not the original owner of this...

    Guessing your not the original owner of this furnace, as if you are and you registered the furnace initially you still would have 4 more years of parts warranty. The HX looks to have a basic 20 year...
  25. Did this Contractor who resealed your ducts also...

    Did this Contractor who resealed your ducts also check the A/C performance. Have you ever had a basic PM check in the 5 years of running it.
  26. You have a inducer exhaust fan, verses maybe the...

    You have a inducer exhaust fan, verses maybe the old one did not, possible one reason the flue temperature is lower? Without knowing the exact model of your Goodman seen several models of the 80%,...
  27. Guessing the ductwork is not correct, as you...

    Guessing the ductwork is not correct, as you mention ducts furthest from the coil. Did you have existing ductwork at your residence and the Contractor made modifications to existing ducts or they...
  28. Replies
    9
    Views
    415

    Call a HVAC company, ask for a seasoned Tech....

    Call a HVAC company, ask for a seasoned Tech. good at low voltage troubleshooting. Ask that person what size heater element you have as one question, then have that person mark it as it says to do...
  29. Yes HVAC is measured in OD.

    Yes HVAC is measured in OD.
  30. That vapor line ( suction line as you call it )...

    That vapor line ( suction line as you call it ) looks like at least 5/8” OD and not 3/8” OD from here. Yes Technical Services typically do not talk to homeowners, that’s why I referenced having the...
  31. I’m surprised at that size, ( heard of 1/4” OD X...

    I’m surprised at that size, ( heard of 1/4” OD X 5/8” OD ) not so much the Liquid Line but the vapor line. BTW when talking Heat Pump the suction line is actually called the vapor line.....just...
  32. chocolate?

    chocolate?
  33. Docs for unit spec new lineset as 3/8+3/4". ...

    Docs for unit spec new lineset as 3/8+3/4".

    Old, R22 lineset is 1/4+3/8.

    What does the above mean? Your old lineset size?

    Why don’t they bid AHRI matched systems? Ask for something like...
  34. Im guessing the larger line is 5/8” OD? and not...

    Im guessing the larger line is 5/8” OD? and not 3/8” OD.

    What’s wrong with following the manufacturers recommendations in the install guide? Says 3/8” OD X 3/4” OD . Also the install guide says to...
  35. Throw those snowmobiles on your truck, and I’ll...

    Throw those snowmobiles on your truck, and I’ll bring mine and meet you at Old Forge when the snow flies....:whistle:
  36. IDK what to tell you about your current stat...

    IDK what to tell you about your current stat compatibility with the iConfort feature of the EL model.

    BTW your 4A7A may not actually be rated at 14 SEER, as the OD unit alone does not determine...
  37. The ML has a standard 20 year HX warranty and...

    The ML has a standard 20 year HX warranty and looks to have 2 width sizes, whereas the EL has a limited lifetime HX warranty to original registered owner and three width sizes.

    Both have 2 stage...
  38. Replies
    6
    Views
    304

    If your interested in possible rebates and your...

    If your interested in possible rebates and your getting matched systems, include the complete model numbers of furnace, ID coil and OD unit, especially the ID coil number, as the indoor selection...
  39. Replies
    18
    Views
    1,245

    Hey that’s pretty good,...I’ll give you a full...

    Hey that’s pretty good,...I’ll give you a full like. Yes the support brackets alignment on the downspout is pretty good. I like that part.
  40. Replies
    9
    Views
    621

    Believe some manufacturers say ( matched system )...

    Believe some manufacturers say ( matched system ) to use a certain amount of refrigerant for every feet above the initial 15’ of lineset then come back in the warmer weather to fine tune it by...
  41. Replies
    18
    Views
    1,245

    Sounds about right, @500 Sq. Ft. a ton rule...

    Sounds about right, @500 Sq. Ft. a ton rule...
  42. Possible one reason the thermostat cycles back on...

    Possible one reason the thermostat cycles back on after only one minute is behind the thermostat where the wires hook up to the thermostat subbase the hole is large and it has cold air in that chase,...
  43. I “assume” if we were to have to replace the...

    I “assume” if we were to have to replace the units that they would be matched units and properly installed.

    I would not assume anything, I would request matched AHRI system in order to sign an...
  44. “I will say that our Carrier performance Heat...

    “I will say that our Carrier performance Heat pumps have performed well and seem very quite...”

    Your existing 13/14 SEER systems are probably relatively uncomplicated even with the current faults....
  45. Sooorry for the disinformation

    Sooorry for the disinformation
  46. https://www.lennoxpros.com/docs/Technical/210667.p...

    https://www.lennoxpros.com/docs/Technical/210667.pdf dated 2019

    Says you have the Quantum coil, which says it’s made for corrosion.
    ...
  47. Replies
    7
    Views
    317

    Here’s the spec. sheet on both. Forgot to...

    Here’s the spec. sheet on both. Forgot to mention, if compressor ever fails on the GSZC16 within the 1st 10 years of ownership, you get a new OD unit, not a compressor like most other manufacturers,...
  48. Replies
    7
    Views
    317

    The GSZC16 has a limited lifetime compressor...

    The GSZC16 has a limited lifetime compressor warranty to the original registered owner whereas the GSZ16 has a 10 year warranty, both have a 10 year parts warranty once registered.
  49. Ask for a AHRI system, as besides getting a...

    Ask for a AHRI system, as besides getting a matched system, and knowing the SEER, EER, HSPF of that system on paper, not really real world numbers ( as you can not go by the OD unit rating alone )...
  50. Replies
    20
    Views
    749

    From a excerpt from History of Chrysler AirTemp ...

    From a excerpt from History of Chrysler AirTemp

    The good times did not last, as other companies were able to catch up in features and production if not in quality, and the industry quickly shifted...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4