    PCT Sequence of Ops

    Hello

    I'm looking for Johnson's literature for the sequence of operations of a VAV terminal with CO2 min flow reset. They used to give this to you via the asset tool but thats gone. FX builder had...
  2. Replies
    3
    Views
    749

    I was able to find the jar on my vendors ftp...

    I was able to find the jar on my vendors ftp after looking on niagara central for 3 days. It does exist and did fix the problem.
  3. Replies
    3
    Views
    749

    Weather.Jar Niagara 3.4.43

    Hello, I have a jace running 3.4.43. Where can I find the patched Weather.jar for 3.4 which fixes the re-direct error and causes the jace to reboot?

    This is what I see when I try to update the...
  4. Replies
    2
    Views
    611

    Platform N2 errors

    N2 Platform Errors on FX60
    Hello,

    I have a FX60 with 71 VMAs and 2 UNTs. All of the controllers are online and points work as they should with good polling however I keep getting these errors in...
  5. I called Viconics and the 8600 series is exactly...

    I called Viconics and the 8600 series is exactly what I need. Thanks
  6. 7 Day Programmable Thermostat with Analog Heating Output

    Hello,

    Im having trouble locating a 7 day programmable thermostat with an analog heating output for a modulating hot water valve.

    This is a non ddc job and the engineer just bounced my...
  7. Replies
    3
    Views
    802

    I am assuming you tried jci / explorer

    I am assuming you tried jci / explorer
  8. Replies
    6
    Views
    1,197

    Yea, I understand. Unfortunately my ISP is...

    Yea, I understand. Unfortunately my ISP is dynamic as well. Is there any controller which offers a mobile app similar to how wifi thermostats operate?
  9. Replies
    6
    Views
    1,197

    Home Automation- Newbie

    Hello,

    I want to be able to control a 24v contactor in my home from my mobile device. I am looking into the ethernet RIB. I dont want to spent a ton of money on this project. Can you guys provide...
  10. Lochinvar Crest AX Integration over modbus

    Hi

    I am having trouble mapping the points in the Lochinvar Crest modbus points list. I keep getting illegal data address. Does anyone know if there is an offset? Has anyone done this integration...
  11. Replies
    3
    Views
    928

    PCT - Custom Enum States?

    I am using PCT version 6 to write a custom program for an air handler. I have hybrid activities I want to label with custom states text. Is this possible? The default available states arent cutting...
  12. Replies
    37
    Views
    17,265

    I did not have the crpto service installed. I...

    I did not have the crpto service installed. I have installed it and still cannot send email from Niagara.
  13. Replies
    37
    Views
    17,265

    with SSL enabled I get this error ERROR...

    with SSL enabled I get this error

    ERROR [15:54:30 10-Oct-13 EDT][email] BEmailAccount could not poll:
    java.lang.Exception: Valid CryptoService not found.
    at...
  14. Replies
    37
    Views
    17,265

    I used a SMTP client application on this network...

    I used a SMTP client application on this network to verify its not a network issue or port blocked. It required me to use TLS. Is TLS supported by Niagara? Also, the email was sent using the SMTP...
  15. Replies
    37
    Views
    17,265

    I am running 3.6.47 Crypto appears to be...

    I am running 3.6.47

    Crypto appears to be licensed.

    <license version="3.7" vendor="Tridium" generated="2013-01-02" expiration="never" hostId="Qnx-NPM6-0000-15F6-4DFD" serialNumber="485036">
    ...
  16. Replies
    37
    Views
    17,265

    yes- same results

    yes- same results
  17. Replies
    37
    Views
    17,265

    Using a GMAIL account in Niagara

    Has anyone successfully used Gmail as a mail relay in Niagara - outgoing account?

    If so, can you post a screenshot of your settings? I cant get this to work for the life of me and I do not think...
  18. Replies
    2
    Views
    1,020

    Anyone

    Anyone
  19. Replies
    2
    Views
    1,020

    Emon Demon and FX60

    Hello,

    I have to setup add an EMON Demon E20-208100-MKIT to a FX60 via a JCI PCG controller. I understand to bring the pulse to a BI and set it up as an accumulator in PCT. From there, I dont know...
  20. Does the drive itself accept your fieldbus? Lon?...

    Does the drive itself accept your fieldbus? Lon? Which can tell you the speed?
  21. Cutler hammer/ johnson controls drives will...

    Cutler hammer/ johnson controls drives will accept floating control (motor pot up pot down)
  22. I used one kele pwa-1t this week with good...

    I used one kele pwa-1t this week with good results.
  23. Replies
    1
    Views
    2,888

    Help with Niagara Bformat text

    I have an enumeration set which Id like to add an enum COS alarm extension. I want to include the enumerated text in the off normal alarm text.
    For example, 0 = Normal, 1= Low Pressure, 2= Fan...
  24. Replies
    14
    Views
    7,228

    Ok you should see the one and only station on...

    Ok you should see the one and only station on your jace. Delete it and then go to Tools, New Station. Hope this helps.
  25. Replies
    14
    Views
    7,228

    Are you in the platform of your computer? Make...

    Are you in the platform of your computer? Make sure you are in the platform of your jace
  26. Replies
    14
    Views
    7,228

    I would make a new station. I believe its Tools...

    I would make a new station. I believe its Tools --> New Station. You may need to be in the app director
  27. Replies
    1
    Views
    946

    Make sure there are no duplicate bacnet...

    Make sure there are no duplicate bacnet instances. I assume you're using a RS485 expansion?
    Keep an eye on the busy time on the trunks with that many controllers you may need to slow polling down
  28. Replies
    13
    Views
    3,378

    Apparently I signed up and now I am getting...

    Apparently I signed up and now I am getting emails asking me to update my "status"... I looked around and its pretty useless
  29. Replies
    15
    Views
    5,575

    Can you send me the info as well as I'm actually...

    Can you send me the info as well as I'm actually in need of a fix
  30. Replies
    15
    Views
    5,575

    The field server controller points for the Camus...

    The field server controller points for the Camus boilers is going in and out of fault quickly. I saw this same issue on the PCG controller when I used a low bacnet instance number... (104). Changing...
  31. Replies
    15
    Views
    5,575

    a +, -, and Common are landed. The shield is back...

    a +, -, and Common are landed. The shield is back wrapped.... When the shield was connected, I saw nothing on the trunk.
  32. Replies
    15
    Views
    5,575

    Bacnet Comm error- ACH550, AX

    I'm getting these Bacnet comm errors from an ABB ACH 550 connected over 22/3 @19,200 baud. Theres only 5 controllers on this 25 foot fieldbus. I only have added 11 points from this VFD thus far. Some...
  33. Replies
    2
    Views
    1,116

    I can't even get a sequence of operations for...

    I can't even get a sequence of operations for their application wizards never mind training material
  34. Replies
    4
    Views
    892

    I think I should be able to do this using the...

    I think I should be able to do this using the read/write attributes function in PCT but I keep getting an error after changing the Bacnet ID and clicking write attributes : "No attributes are defined"
  35. Replies
    4
    Views
    892

    PCV1620 and bacnet device instances

    Is it possible to change the device instance on a PCV1620 once its been programmed (without re-downloading to the box)? I have duplicate device instances on different fieldbuses and different...
  36. Thanks Dan... The factory rep sent me a link to...

    Thanks Dan... The factory rep sent me a link to the pulse option doc which didn't exactly apply when I asked him some questions...

    Thanks for being thorough
  37. 359651359661 Heres the logic. The data is in...

    359651359661

    Heres the logic. The data is in fault because I ran the station offline.
  38. anyone?

    anyone?
  39. Help with intellimeter A277 demand meter in AX

    I have several Intellimeter A-277 electrical meters that I must connect to a FX60.

    I have these pulse inputs tied into a PCG1711 controller and setup as accumulators. I have inferred that the...
  40. The PT link is wattmaster. I would try to call...

    The PT link is wattmaster. I would try to call them with any questions regarding the PT link and points communicated over it.
  41. Fixed. Tech support had me hardcode the JACES...

    Fixed. Tech support had me hardcode the JACES bacnet network # into the 812u via BacView. BacView Password was 09876
  42. Trouble w Mammoth RTU I/O Pro 812U Bacnet

    I am trying to connect an FX60 to a mammoth RTU with a I/O Pro 812u. I am connecting with a 3' piece of wire from the internal RS485 card to the port2a (net+, net-). I have setup bacnet correctly and...
  43. Replies
    7
    Views
    2,131

    I should add that cycling power or recalibrating...

    I should add that cycling power or recalibrating the DP does not help when the controller is reading supply flow of zero.

    When the controller is reading zero in these cases, I am able to measure...
  44. Replies
    7
    Views
    2,131

    FXVMA Questions

    I have installed over 300 FXVMAs (N2). I am using the FX Builder Application Wizard to generate APDs for terminal boxes. These are mostly fan powered electric heat and cool only vavs. There are over...
  45. Replies
    1
    Views
    970

    Niagra owner training tips/documents

    I have been asked to do some owner training on sites which we have installed FX60s with VAVs, RTUs, and FTPs along with some custom applications.

    I'm trying to put together some hand outs to aid...
  46. Replies
    5
    Views
    1,277

    The boss has decided to use one of the available...

    The boss has decided to use one of the available DOs and wire it in parallel with the PAT unload relay. Doing so will let me unload the compressor upon compressor enable command, and unload the...
  47. Replies
    5
    Views
    1,277

    Im not sure that I understand how the DAT block...

    Im not sure that I understand how the DAT block will help me with the compressor drifting.

    The calculated load is 0 percent but the compressor is loading on its own. I need to back this off and at...
  48. Replies
    5
    Views
    1,277

    Help with FX PAT DO / Scroll Compressor

    Im using an FX15 to write a program for a RTU which has a scroll compressor. I'm using a PAT DO (Position Adjust Timer) block to LOAD/UNLOAD the compressor via 2 binary outputs (Floating Control)
    ...
  49. Replies
    3
    Views
    910

    customer says they have never adjusted the Static...

    customer says they have never adjusted the Static Pressure or DAT setpoint on the controller in question. Customer says they think those points are not writable. Perhaps the NAE is pointing to the...
  50. Replies
    3
    Views
    910

    The NAE sends the out of service value. I have...

    The NAE sends the out of service value. I have tried toggling this to TRUE, then adjusting the actual setpoint (calculated) as shown on the NAE.