    Compressor doesn't require a ground for it to...

    Compressor doesn't require a ground for it to operate.

    Lots of compressors out there that are not grounded, or grounded properly.
  2. Replies
    46
    Views
    677

    A weak compressor wouldn't draw a high vacuum on...

    A weak compressor wouldn't draw a high vacuum on either line.

    The slight vacuum on the small line just shows that a small amount of refrigerant is being pumped. Which points to a low charge.
  3. Replies
    46
    Views
    677

    No, still looks like a low charge.

    No, still looks like a low charge.
  4. Replies
    4
    Views
    216

    Moved to the Junk Yard forum. This is the...

    Moved to the Junk Yard forum.

    This is the forum foe selling things.
  5. Prices are not allowed, I removed them.

    Prices are not allowed, I removed them.
  6. Replies
    15
    Views
    327

    Moved to AOP.

    Moved to AOP.
  7. Replies
    5
    Views
    252

    Verify air flow is not low. What is the temp...

    Verify air flow is not low. What is the temp split across the evap coil/air handler.
  8. Replies
    46
    Views
    677

    On a mini split, that small line is not a liquid...

    On a mini split, that small line is not a liquid line.

    You described a system low on charge.
  9. Replies
    5
    Views
    122

    Hope those 8 flex ducts are a combination of 8...

    Hope those 8 flex ducts are a combination of 8 and 9" ducts. Other wise you have a low air flow issue.

    And your 24x30 return grille is a bit small for a 4 ton system.
  10. Replies
    1
    Views
    139

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  11. Replies
    17
    Views
    253

    Prices are not allowed, I removed them.

    Prices are not allowed, I removed them.
  12. Replies
    12
    Views
    782

    That thermostat doesn't have a settable extended...

    That thermostat doesn't have a settable extended fan option.
  13. Replies
    12
    Views
    782

    Nope, thats not it. Whats the full model...

    Nope, thats not it.

    Whats the full model number of your thermostat.
  14. Has someone else been working on it recently.

    Has someone else been working on it recently.
  15. Replies
    12
    Views
    782

    In the installer menu, thee are extended fan run...

    In the installer menu, thee are extended fan run time options.
  16. Sorry, prices are not permitted here, they have...

    Sorry, prices are not permitted here, they have been removed.
  17. LOL. Only Pro members have PM privileges. So...

    LOL.

    Only Pro members have PM privileges. So the OP can't send or receive PMs.
  18. Replies
    19
    Views
    411

    Moved to AOP.

    Moved to AOP.
  19. Replies
    14
    Views
    361

    Moved to AOP.

    Moved to AOP.
  20. Good chance, its just the thermostat.

    Good chance, its just the thermostat.
  21. 1500 CFM is probably fine being that its in first...

    1500 CFM is probably fine being that its in first stage.
  22. Replies
    1
    Views
    104

    Maybe get a better company to service your unit....

    Maybe get a better company to service your unit. One that will find and fix the leak.
  23. Replies
    7
    Views
    294

    Too powerful of a furnace won't cause the A/C to...

    Too powerful of a furnace won't cause the A/C to freeze up. You have a low air flow issue most likely. Or an improperly installed evap coil.
  24. Replies
    7
    Views
    273

    Is your employer your wife? Your a DIYer.

    Is your employer your wife? Your a DIYer.
  25. Replies
    10
    Views
    238

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  26. Replies
    17
    Views
    445

    The dye travels with the oil, which travels with...

    The dye travels with the oil, which travels with the refrigerant.

    Its a relatively small amount of oil that travels with the refrigerant, so not much oil or dye circulates in 30 minutes.
    ...
  27. Replies
    5
    Views
    196

    Honeywell IAQ.

    Honeywell IAQ.
  28. Replies
    17
    Views
    445

    Some leaks are hard to find. And need to have the...

    Some leaks are hard to find. And need to have the system recovered except for a few ounces as trace gas, and then nitrogen used to bring the system up to a high pressure and checked.

    Most leak...
  29. Replies
    46
    Views
    839

    Yes.

    Yes.
  30. Replies
    19
    Views
    644

    5,000 sq foot house with a 4 ton A/C. 1,250 sq ft...

    5,000 sq foot house with a 4 ton A/C. 1,250 sq ft per ton, on a 20 plus year old house. Might be a tad small.

    Same with furnace.

    Ask the company how they determined what size equipment to...
  31. Replies
    23
    Views
    473

    I only use the contractor models. So I don't know...

    I only use the contractor models. So I don't know which if any box store models have it or not.
  32. Replies
    23
    Views
    473

    Its not a feature that automatically pops up. If...

    Its not a feature that automatically pops up. If your thermostat has that feature. It has to be enabled in the set up menu.
  33. Replies
    45
    Views
    669

    Ah, forgot its an electric furnace. Its okay...

    Ah, forgot its an electric furnace. Its okay then. I was thinking gas furnace at first.


    And on a side note. Have them check if one of the electric heaters is coming on with the A/C.
  34. Replies
    45
    Views
    669

    The A coil is NOT suppose to be on top of a...

    The A coil is NOT suppose to be on top of a downflow furnace. Its detrimental to the furnace. Causes the heat exchanger to rust from the inside out.
  35. Replies
    45
    Views
    669

    A coil on top? Is this an upflow or downflow...

    A coil on top? Is this an upflow or downflow furnace?
  36. Replies
    41
    Views
    907

    From what several members said a long time ago....

    From what several members said a long time ago. It was common in Florida at one time.
  37. Replies
    45
    Views
    669

    More often than not, techs don't crawl under the...

    More often than not, techs don't crawl under the home and check the ducts.
  38. Replies
    4
    Views
    225

    Could be a orifice/TXV issue, or a low air flow...

    Could be a orifice/TXV issue, or a low air flow issue, or a restricted LLFD issue.

    SH and SC would have probably pointed you in the right way.
  39. Replies
    45
    Views
    669

    Should check to make sure non of the ducts under...

    Should check to make sure non of the ducts under the home are disconnected. And make sure the ducts are properly attached to the unit.
  40. The Ultra Aire will be a higher quality unit.

    The Ultra Aire will be a higher quality unit.
  41. No, its not harmful. And might even save enough...

    No, its not harmful. And might even save enough money in ten years to pay for the insulation.
  42. Replies
    23
    Views
    473

    We have a contractor locator map of this boards...

    We have a contractor locator map of this boards members. See if any are listed on it. The link to it is in my sig.
  43. Prices removed.

    Prices removed.
  44. Replies
    41
    Views
    907

    Your not charged based on amp draw. But rather by...

    Your not charged based on amp draw. But rather by wattage. Many forget this when they see a lower amp draw on a 3 phase unit the same size as a single phase unit.

    Same amount of wattage whether...
  45. A good nitrogen flush/purge is all that is needed.

    A good nitrogen flush/purge is all that is needed.
  46. Yes, you posted prices. I also removed the new...

    Yes, you posted prices.

    I also removed the new prices you posted.

    https://hvac-talk.com/vbb/showthread.php?1241-Welcome-to-HVAC-Talk!-Please-read-these-rules
  47. Prices are not allowed.

    Prices are not allowed.
  48. Replies
    12
    Views
    259

    Sorry, prices are not allowed.

    Sorry, prices are not allowed.
  49. So did the installers come back and find the...

    So did the installers come back and find the problem.
  50. Replies
    36
    Views
    1,099

    Page 15. The system should be liquid-charged...

    Page 15.

    The system should be liquid-charged through the liquid-receiver shut-off valve or through a valve in the liquid line. The use of a filter drier in the charging line is ...