Search:

Type: Posts; User: joey791

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    2
    Views
    236

    You can connect to the USB but only to set some...

    You can connect to the USB but only to set some controller settings, you can't upload a database by USB.
  2. Replies
    18
    Views
    663

    Now that really blows, the jace I had the issue...

    Now that really blows, the jace I had the issue with was a Lynxspring Jace, I forget what the highest version they found but I believe it was a 3 series jace, the asd driver wouldn't work, I had to...
  3. Replies
    18
    Views
    663

    I don't know how you got it to work on 3.8, the...

    I don't know how you got it to work on 3.8, the asd jar file isn't supposed to work after like 3.4, had this problem a few months ago. You will have to get the ibmsasd jar and use it and pay for the...
  4. Replies
    11
    Views
    470

    https://www.trane.com/commercial/north-america/us/...

    https://www.trane.com/commercial/north-america/us/en/products-systems/equipment/unitary/variable-air-volume/Shut-off/round-in-round-out-.html
  5. Replies
    4
    Views
    510

    Nick, that job we talked about, I got in the jace...

    Nick, that job we talked about, I got in the jace as an admin and never could find a way to configure the controllers either.
  6. Replies
    8
    Views
    847

    Mikey, put your email in your profile, I'll email...

    Mikey, put your email in your profile, I'll email you and we can hook up.
  7. Replies
    2
    Views
    263

    Rockwell PLCs, that's really overkill.

    Rockwell PLCs, that's really overkill.
  8. Replies
    15
    Views
    637

    We did a job awhile back and thought about using...

    We did a job awhile back and thought about using a LGate, it was more expensive than a Jace with everything to do the job. Pricing varies though.
  9. Replies
    9
    Views
    561

    The company I currently work for has a hotel we...

    The company I currently work for has a hotel we have done work for in a major market that has somewhere in the neighborhood of 200 ASI controllers in it, a mix of controllers from 3 generations ago...
  10. Replies
    9
    Views
    561

    The deal with the ASI comms is backwards...

    The deal with the ASI comms is backwards compatibility, the original controls made can talk to the current line, everything has always been backwards compatible, you don't want to sell someone a...
  11. Replies
    9
    Views
    561

    It's mostly Bacnet now and they are coming out...

    It's mostly Bacnet now and they are coming out with a Tridium driver for the ASI protocol.
  12. Replies
    9
    Views
    561

    Their stuff is full Bacnet, I worked for a rep...

    Their stuff is full Bacnet, I worked for a rep over 10 years, just when the first Asic/3s started rolling out, have a ton of drop in programs in my library from anything from chill water air...
  13. Replies
    11
    Views
    585

    They are setup with WPT 3.2, you have to upgrade...

    They are setup with WPT 3.2, you have to upgrade them to the current version.
  14. Replies
    11
    Views
    585

    Jacob, my email is in my profile, shoot me one.

    Jacob, my email is in my profile, shoot me one.
  15. I use nothing but hyperterminal, your baud rate...

    I use nothing but hyperterminal, your baud rate is wrong. Look in the jace manual it will tell you what baud rate to use for what type Jace.
  16. Replies
    3
    Views
    322

    Does it have the hole for a plug with the red...

    Does it have the hole for a plug with the red insert in it?
  17. Replies
    3
    Views
    322

    Just pulled up the W7100J manual, it's supposed...

    Just pulled up the W7100J manual, it's supposed to be 2 minutes between stages, if you look at the troubleshooting in the back with the test plug in the stages will stage up every 10 seconds.
  18. Replies
    17
    Views
    1,181

    Sorry been busy, if you set a relinquish default...

    Sorry been busy, if you set a relinquish default value, it automatically writes that value to the point, which when not in use should be --. When that point has a value the user cannot adjust the...
  19. Replies
    17
    Views
    1,181

    Yes AV

    Yes AV
  20. Replies
    17
    Views
    1,181

    Btw that's default, writes work correctly, it's...

    Btw that's default, writes work correctly, it's just when you dont use the point.

    Sent from my SM-G960U using Tapatalk
  21. Replies
    17
    Views
    1,181

    Max, the point in the Jace both from the and...

    Max, the point in the Jace both from the and device and leaving the Jace bacnet ip shows a null value, nothing, just dashes.

    Sent from my SM-G960U using Tapatalk
  22. Replies
    17
    Views
    1,181

    Well it turned out to be a huge cluster, but I...

    Well it turned out to be a huge cluster, but I got through it, this is the second one I have done. I did a Google search and like I said I'm sending these points out Bacnet I/P through the Jace to...
  23. Replies
    17
    Views
    1,181

    Thanks for the help guys, this is the first time...

    Thanks for the help guys, this is the first time I've ever had to do this.
  24. Replies
    17
    Views
    1,181

    Noob AX question

    I have a 600 that was hit by lightning that has to be replaced, the guy who originally did the job is no longer with us. The only backup of the job is a config.bog file, I always, always, always use...
  25. The place I set you up with didn't give you a...

    The place I set you up with didn't give you a shot?
  26. Aero, do I know the large company?

    Aero, do I know the large company?
  27. I'm happy I always worked commercial.

    I'm happy I always worked commercial.
  28. Thread: TAC MN-CIM

    by joey791
    Replies
    8
    Views
    557

    I need one for a project we picked up, what you...

    I need one for a project we picked up, what you want for it

    Sent from my SM-G960U using Tapatalk
  29. Thread: TAC MN-CIM

    by joey791
    Replies
    8
    Views
    557

    send me an email if you want to get rid of it, or...

    send me an email if you want to get rid of it, or if you need a controller or something in trade, etc.
  30. Thread: TAC MN-CIM

    by joey791
    Replies
    8
    Views
    557

    Little black 9 pin serial interface with a curled...

    Little black 9 pin serial interface with a curled cable with something close to a headphone jack on the other end.
  31. Thread: TAC MN-CIM

    by joey791
    Replies
    8
    Views
    557

    TAC MN-CIM

    Looking for one, shoot me an email.
  32. Replies
    7
    Views
    586

    First N4 job, seems like the only thing I could...

    First N4 job, seems like the only thing I could change it to was an admin, I changed the password on it to, I did the last one a year ago so I completely forgot or thought I looked at it and I was...
  33. Replies
    7
    Views
    586

    Thanks for all the replies, it's been a year...

    Thanks for all the replies, it's been a year since I've put a Jace in, don't use them that often anymore, I had to change my Bacnet user privileges, also had to set a value, not null for my Boolean...
  34. Replies
    7
    Views
    586

    N4 ASD Driver Issue

    I'm integrating into so MN-FLO3Ts through some MN-ASDI, i have no problem discovering the controllers or the points, I have created a Bacnet Export Table to push the points out to another device,...
  35. Replies
    8
    Views
    978

    Worked great, why isn't Lucid default

    Worked great, why isn't Lucid default
  36. Replies
    8
    Views
    978

    N4 Workbench Color Scheme Change

    Doing my first N4 Jace, I take 3 anti-depressants a day, this default gray and white scheme is making me even more depressed, is there away to change the color scheme of the workbench interface?
  37. Replies
    2
    Views
    547

    Thanks digo, I was able to get into the Jace and...

    Thanks digo, I was able to get into the Jace and get a list.
  38. Replies
    10
    Views
    1,719

    We use them all the time ...

    We use them all the time

    https://www.trane.com/content/dam/Trane/Commercial/global/products-systems/equipment/unitary/variable-air-volume/round-in-round-out/VAV-PRC016A-EN_03162018.pdf
  39. Aero, I sent you 2 jobs to apply for, good luck.

    Aero, I sent you 2 jobs to apply for, good luck.
  40. Replies
    16
    Views
    1,170

    Just used one of these to do Modbus TCP to Bacnet...

    Just used one of these to do Modbus TCP to Bacnet IP, it was only 4 points but it was really easy.
  41. Aero, put your email in your profile, I have some...

    Aero, put your email in your profile, I have some job opportunities I can send you.
  42. Replies
    3
    Views
    433

    techdr, let me know if you pull out the 9540s, I...

    techdr, let me know if you pull out the 9540s, I need one for my test bench, thanks.
  43. Replies
    2
    Views
    547

    Points list for Staefa Talon Vav

    Found one for a loop controller but can find the SNVT list for a vav, any help wouls be appreciated.

    Sent from my SAMSUNG-SM-G930A using Tapatalk
  44. Replies
    6
    Views
    691

    If anyone has any asic devices they pull out I'm...

    If anyone has any asic devices they pull out I'm looking for a couple for my test bench, email me.
  45. Replies
    6
    Views
    691

    On the Asic/2 they use their proprietary ASI...

    On the Asic/2 they use their proprietary ASI protocol on the system and local bus, you have to have a 7540 to talk Modbus on the local bus, the 7040 only speaks ASI. How many devices onsite? If they...
  46. Replies
    11
    Views
    1,105

    Emulation has to be set to VT100 for it to work,...

    Emulation has to be set to VT100 for it to work, I have 8 Companion panels sitting in my laundry room if you need another one lol
  47. Replies
    3
    Views
    1,214

    Only the Loytec controller is left, all software...

    Only the Loytec controller is left, all software and Bluetooth adapter is sold.
  48. Replies
    3
    Views
    1,214

    Email sent, please put your email in your...

    Email sent, please put your email in your profile, we are not supposed to post them on the forum, thanks.
  49. Replies
    3
    Views
    1,214

    Carrier controls software and FX BTCVT

    Carrier Network Service Tool V, used once on my test bench, software and USB interface 1400.00
    Carrier I-vu Tech Tools version 5.1 software and interface cables brand new 500.00
    Johnson Controls...
  50. Replies
    13
    Views
    2,323

    https://ecobuilding.schneider-electric.com/transit...

    https://ecobuilding.schneider-electric.com/transition-to-smartstruxure/tac-ia-series#tab/documents