    That's a BadRate alright. The MSTP driver only...

    That's a BadRate alright.

    The MSTP driver only supports standard baud rates.

    Setting is under Driver-Bacnet Network-Bacnet Comm-Network-MSTP Port
  2. Thread: History point

    by orion242
    Replies
    3
    Views
    252

    There are triggered histories in ax com or...

    There are triggered histories in ax com or vykonpro that come in handy for certain apps.

    This is muddy yet. COV histories are not the easiest to work with when you mix in other types or want to...
  3. Replies
    7
    Views
    367

    Thanks, I did finally get it through offical...

    Thanks, I did finally get it through offical channels. I will say it was a hassle obtaining updates compared to purchasing it via the same avenues.
  4. Replies
    7
    Views
    367

    Seems it takes a bit of persistence. Haven't had...

    Seems it takes a bit of persistence. Haven't had the time to try the last few responses I got back.

    Far as I have gathered so far r1.3.0.1 is current.
  5. Replies
    7
    Views
    367

    KMC support flipped me to the local dealer,...

    KMC support flipped me to the local dealer, guessing that's a dead end. See what Kele has too say.
  6. Replies
    7
    Views
    348

    https://catalog.weidmueller.com/catalog/Start.do?l...

    https://catalog.weidmueller.com/catalog/Start.do?localeId=en_DE&ObjectID=8739140000

    Manuals there. Shouldn't be a problem.

    Would look at the current between supplies and load and see if...
  7. Replies
    7
    Views
    367

    Will be going down the same path. Won't be...

    Will be going down the same path. Won't be impressed with a device anyone can purchase yet the updates are unobtainable.
  8. Replies
    53
    Views
    19,061

    Maybe try the links ~3 posts below...

    Maybe try the links ~3 posts below...
  9. Replies
    40
    Views
    1,473

    You shouldn't have an issue getting certs for...

    You shouldn't have an issue getting certs for FQDNs using DDNS or publicly routable IPs.

    CAs might thumb their nose at xyz.noip.com, but you can register xyz.com and add DDNS to that and get a...
  10. Replies
    9
    Views
    463

    Can only have a single Modbus master on a 485...

    Can only have a single Modbus master on a 485 network, so your not getting far if you cannot reconfigure the existing setup.
  11. Replies
    6
    Views
    303

    Older AX versions and current browser have had an...

    Older AX versions and current browser have had an issue that just brings up a blank page after login.

    Use current IE & Java. Add the page to compatibility views in IE. Might have to add a...
  12. Replies
    12
    Views
    411

    Full serial has the options to change the IP,...

    Full serial has the options to change the IP, reset platform creds, etc.

    IPL is the IPL> command prompt. That's where the memory tests are. If the Jace only boots to that point, its warranty...
  13. Replies
    12
    Views
    411

    Ditto on the bad blocks, seen this on more than...

    Ditto on the bad blocks, seen this on more than one working unit.

    If a Jace only boots to the IPL command line, its usually a door stop. If you can get to the full serial shell menu, its normally...
  14. Replies
    12
    Views
    411

    Stuff in the data recovery folder. Normally dump...

    Stuff in the data recovery folder. Normally dump it all, but if you want to be safe just get all the old files and keep the 3-4 most recent.
  15. Replies
    12
    Views
    411

    Sounds like the data recovery bug. Delete some...

    Sounds like the data recovery bug.

    Delete some / all of those files, reboot and then upgrade to the latest 3.7 version.
  16. Replies
    40
    Views
    1,473

    Think your missing the point behind running a...

    Think your missing the point behind running a VPN. One key benefit is it prevents all these port scanning services from enumerating whatís behind a connection. Rather trivial to hunt for known...
  17. Second that. Audit trail isn't a strong point...

    Second that.

    Audit trail isn't a strong point with RC.

    System PW change, aweful.
  18. Replies
    2
    Views
    169

    And thank you HW for making this PITA when they...

    And thank you HW for making this PITA when they share about everything...that works at least.

    If your dealing with a mixed AX/N4 site, typically you run the N4 demon and launch AX without. Aka,...
  19. Replies
    4
    Views
    229

    Seen this several times. Virtual objects come...

    Seen this several times.

    Virtual objects come in and everything reads, but the proxy points are a claiming unknown object which is BS. You can do a point discovery and everything shows up valid...
  20. Replies
    84
    Views
    3,946

    Why I would trust one of my controllers to...

    Why I would trust one of my controllers to provide this functionality over commodity networking gear? Can see more than one IT dept that would forbid it. Why bother go that route if you have...
  21. Replies
    84
    Views
    3,946

    With STP you don't need the loops starting and...

    With STP you don't need the loops starting and terminating on the same switch. You could have a string of devices between switches in mech rooms and a second, third, etc redundant links shooting...
  22. Replies
    40
    Views
    1,473

    Only if its Traget's IT dept, lol. You can...

    Only if its Traget's IT dept, lol.

    You can limit access to just whats required with most VPN solutions.
  23. Replies
    84
    Views
    3,946

    Almost positive they have TX/RX packet by port. ...

    Almost positive they have TX/RX packet by port. Only traffic I would expect on blocking ports is STP, next to nothing vs forwarding ports. Should be a fairly easy to sort out based on that. You...
  24. Replies
    84
    Views
    3,946

    Also would hope in this day and age this isn't an...

    Also would hope in this day and age this isn't an issue. Validate new firmware / program validity before overwriting seems to be more common at least what I see. Unless power is lost at the exact...
  25. Replies
    84
    Views
    3,946

    Hey now, we are FX "partners"! Are we second...

    Hey now, we are FX "partners"! Are we second class JCI citizens? Do we not bleed blue if you stick us?

    Lol.

    Firmware updates are a pretty rare event, any benefit is going to be a real fringe...
  26. Replies
    44
    Views
    3,364

    More good PR for cloud services, including IBM's....

    More good PR for cloud services, including IBM's.
    ...
  27. Replies
    7
    Views
    249

    Are you trying to use a USB 485 adapter to pull...

    Are you trying to use a USB 485 adapter to pull MSTP into a supervisor? Not going to work if that's the case.
  28. Replies
    84
    Views
    3,946

    Would really have to wonder what advantage MRP is...

    Would really have to wonder what advantage MRP is going to provide to any BMS. The convergence time is quicker, but at the speeds BMS controllers are operating their likely isnít any noticeable...
  29. Replies
    4
    Views
    283

    You need to make a new BACnet device, then add...

    You need to make a new BACnet device, then add BACnet proxy points under that and link up your logic.

    Here are the points I normally use on the ACH550 with the full profile. Just monitoring so...
  30. Replies
    2
    Views
    184

    You have to use those on the wiresheets under a...

    You have to use those on the wiresheets under a spudder.
  31. Replies
    84
    Views
    3,946

    No doubt about it. Who wants to send money to...

    No doubt about it. Who wants to send money to their competitor? They can't even make a good markup on it because anyone can get it from a half dozen other sources.
  32. Replies
    84
    Views
    3,946

    Depends on what your working with. There are...

    Depends on what your working with. There are devices that spec min scan time regardless of program size. Its a guaranteed min service level rather than an optimistic sales claim that only happens...
  33. Replies
    84
    Views
    3,946

    You might be right. Need to double check my...

    You might be right. Need to double check my notes. Thinking about it more, the edge control engine was running long before the full Niagara stack. Scan time still is pretty poor. The cpier is...
  34. Replies
    84
    Views
    3,946

    There are modules that do this when they loose...

    There are modules that do this when they loose power. Would bet this becomes pretty common if all IP devices take off. Nice feature to have, though I wonder in practice if you don't still lose a...
  35. Replies
    84
    Views
    3,946

    Looking at the edge10 and ciper controllers, it...

    Looking at the edge10 and ciper controllers, it seems they have a long ways to go. Sure 10+ min boot times might be fine in most cases, central plants and critical gear that's simply not acceptable....
  36. Report back on the performance difference. In...

    Report back on the performance difference.

    In theory it should be way better than what you had. I'm wondering if these devices are either underpowered or just have a horrible BACnet stack hence...
  37. Replies
    84
    Views
    3,946

    Hows that really change much? Been pretty easy...

    Hows that really change much? Been pretty easy to get everything on IP regardless and do that for a while now.

    ...as long as its not ARCnet that is... ;)
  38. Wow. For an expensive looking device, that's an...

    Wow. For an expensive looking device, that's an epic fail. Its BACnet performance will be always be total garbage as you found out.

    What protocol are you trying to covert to from BACnet? If...
  39. Replies
    1
    Views
    181

    http://www.kele.com/Catalog/21%20Temperature/Web%2...

    http://www.kele.com/Catalog/21%20Temperature/Web%20Images/ACI-AN-O.jpg
  40. Replies
    22
    Views
    1,043

    Exactly. They are a rock when you need to...

    Exactly. They are a rock when you need to restart them. Dead in the water for how long? Even input to output time isn't anything to write home about.

    Smoke rating, bit of a problem till they...
  41. Replies
    5
    Views
    274

    Ditto. Daiken hasen't ever setup my...

    Ditto.

    Daiken hasen't ever setup my controllers and I'm not going setting up theirs either.
  42. Replies
    5
    Views
    274

    Needs to be configured before you will see any...

    Needs to be configured before you will see any points, least that was the case last time I ran into one. Search the forum, the software has been linked to here several times.
  43. Replies
    2
    Views
    237

    Both AX & N4 community modules are maintained on...

    Both AX & N4 community modules are maintained on sourceforge. Any updates, that's where your going to find them.
  44. Don't think there is a way in the stock modules...

    Don't think there is a way in the stock modules to add/delete files from the browser. Might be some addon you can get.

    Seems like a dangerous feature if not handled carefully.
  45. Replies
    2
    Views
    270

    Bit dated but take a look at this ...

    Bit dated but take a look at this

    https://hvac-talk.com/vbb/showthread.php?1701561-Niagara-AX-Building-History-Reports-for-PX-Views

    You may also want to look at the analytics charts. Not...
  46. Replies
    1
    Views
    168

    Its doing that because your machine isn't...

    Its doing that because your machine isn't licensed. Most of the time you need to take your hostID displayed there and get with your channel to get a license.



    You don't have one from the...
  47. Ditto on the max info frames. You could also...

    Ditto on the max info frames. You could also kick up the baud rate. Either will drop your update rates by a much larger factor than swapping those handful of devices to slaves.

    Given that...
  48. Replies
    3
    Views
    348

    Use workbench and connect to the platform and...

    Use workbench and connect to the platform and change it under platform admin.
  49. WB doesn't need the daemon running to make a...

    WB doesn't need the daemon running to make a connection to a remote device.

    >java.net.ConnectException: Connection refused: connect

    Would be looking at the following myself...

    Wrong IP...
  50. Replies
    10
    Views
    485

    485 needs a ground reference, be it 3-wire or...

    485 needs a ground reference, be it 3-wire or 2-wire with common ground. Likely your issue.

    Field servers getting sent to a site unconfigured will normally show up as a device with no points. If...