Search:

Type: Posts; User: EugeneTheJeep

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    32
    Views
    886

    So, he does not know what kind of tank to use?

    So, he does not know what kind of tank to use?
  2. Replies
    32
    Views
    886

    DIY?

    DIY?
  3. Replies
    44
    Views
    11,345

    Maybe Radwell can rebuild them? But they are...

    Maybe Radwell can rebuild them? But they are behind too.

    Actually they do, and sell lots of parts.

    https://www.radwell.com/en-US/Search/?q=manitowoc+ice
  4. Replies
    44
    Views
    11,345

    I have changed a few hoshi evaps as well, Under...

    I have changed a few hoshi evaps as well, Under the 5 year warranty.
  5. Replies
    11
    Views
    445

    Just charge it to 5 degrees SH at the SSV if its...

    Just charge it to 5 degrees SH at the SSV if its a leaker, or recover and weigh in the nameplate amount, if you want it perfect.
    I can't think of a brand that doesn't want the charge weighed to spec.
  6. Replies
    44
    Views
    11,345

    I just replaced a 2 year old Manitowoc with a...

    I just replaced a 2 year old Manitowoc with a Hoshizaki on Tuesday. The customer could not wait for the new Manitiowoc board. I now have 2 of them down, waiting for the control board.
    Hoshi's do...
  7. Keep in mind, with dirt and corrosion on the...

    Keep in mind, with dirt and corrosion on the coils, your old 2.5 ton system is not putting out 2.5 tons.
  8. If it were my house, I would pick the 1.5 ton...

    If it were my house, I would pick the 1.5 ton system.
  9. Well if you take a shot on the blower motor you...

    Well if you take a shot on the blower motor you are out $XXXX
    If it breaks down again that would bring it to $XXXXX if you do a replacement.
    I would replace the motor, as the coil is new, and the...
  10. Replies
    16
    Views
    988

    Looks like the roller wheels have a little too...

    Looks like the roller wheels have a little too much spread for 1/4 and maybe even 3/8.
  11. Replies
    16
    Views
    988

    Thanks for the input, but kind of big when...

    Thanks for the input, but kind of big when compared to the M12.
  12. Replies
    16
    Views
    988

    Yes, but I am pretty sure that is 3/8 plumbing...

    Yes, but I am pretty sure that is 3/8 plumbing size, so 1/2 ID. I guess well be doing a lot of hand cutting.
  13. Mine split at the bottom the other day, I poked 2...

    Mine split at the bottom the other day, I poked 2 holes in the fabric part of the zipper just above where it would no longer stay together and put a nylon cable tie above the part that no longer...
  14. Replies
    16
    Views
    988

    Power tubing cutter

    Anyone know of a cordless tubing cutter that cuts 1/4 & 3/8 of tubing. Got a bunch of ductless splits to install, and looking. Could not find anything.
  15. Replies
    57
    Views
    1,236

    Most leaders run low SH at the comp. Many of them...

    Most leaders run low SH at the comp. Many of them have SSV that are rusted out. I actually buy their cap tube for the small systems I service. Large diameter, and never saw one restricted.
    ...
  16. We had one the same, put in leak sealer, 2 years...

    We had one the same, put in leak sealer, 2 years later not a problem.
  17. Covid 19 the ultimate line of BS for everything....

    Covid 19 the ultimate line of BS for everything. :censored:

    But yes, low on gas.
  18. Replies
    13
    Views
    511

    So it worked out fine with a 38K Copeland. The...

    So it worked out fine with a 38K Copeland. The Bristol was physically bigger and heavier.
  19. I bought out a few retirees and have a bunch of...

    I bought out a few retirees and have a bunch of duplicated crap in my shop just the same.
  20. Replies
    60
    Views
    2,188

    Mine get tossed after 2 summers, stains, fabric...

    Mine get tossed after 2 summers, stains, fabric pilling, and rips. I want to look good.
  21. Replies
    60
    Views
    2,188

    Mine get tossed after 2 summers, stains, fabric...

    Mine get tossed after 2 summers, stains, fabric pilling, and rips. I want to look good.
  22. Replies
    60
    Views
    2,188

    It took quite a few washes to break them in, and...

    It took quite a few washes to break them in, and they lasted a lot longer.
  23. Replies
    60
    Views
    2,188

    X2, I liked the old ones I got as a kid, deep...

    X2, I liked the old ones I got as a kid, deep blue, and as stiff as cardboard.
  24. Replies
    27
    Views
    860

    Fan on, or fan auto? So it cools perfectly fine,...

    Fan on, or fan auto?
    So it cools perfectly fine, but never shuts off?
  25. I use a Ranco A30-262.

    I use a Ranco A30-262.
  26. Replies
    27
    Views
    860

    Sounds like good humidity control to me. How...

    Sounds like good humidity control to me.
    How big is the system, how big is the house?
  27. Replies
    60
    Views
    2,188

    My Carharts are pretty baggy. I wear the Carharts...

    My Carharts are pretty baggy. I wear the Carharts in the winter, and in the summer a Red Kap Uniform.
    The uniforms have it all over jeans for summer comfort. You can move easier, they dry very...
  28. Replies
    60
    Views
    2,188

    From my favorite test lab. ...

    From my favorite test lab.


    https://www.youtube.com/watch?v=sU6Y1FH6Ssk
  29. Replies
    13
    Views
    511

    Sort of like the old Semi Carlyle's, they would...

    Sort of like the old Semi Carlyle's, they would bleed the second stage port for easier startup.
  30. Replies
    13
    Views
    511

    Don't most larger hermetics have the high...

    Don't most larger hermetics have the high pressure bypass valve in them?

    BTW, yet to see where that is in your image? "Internal Bleed" option
  31. Replies
    13
    Views
    511

    Not seeing that, but I am going to send that to...

    Not seeing that, but I am going to send that to United and tell them to send me a 38K Copeland.
    Maybe the internal bleed is the high pressure relief?
  32. Replies
    13
    Views
    511

    Thanks for the quick response.:cheers: That...

    Thanks for the quick response.:cheers:

    That one is single phase.
  33. Replies
    13
    Views
    511

    Has 2 Bristol h27a38qdbla

    Has 2 Bristol h27a38qdbla
  34. Replies
    13
    Views
    511

    York tonnage

    Need to replace one of the compressors on a Dh090n15s2daa3a rtu. Distributor says he can't cross the old Bristol compressor. Anyone know the tonnage?

    Thank
  35. I usually don't sweat 1000 BTU either way, it's...

    I usually don't sweat 1000 BTU either way, it's only a matter of a few hours a year, that the cooling equipment will be a little undersized.
  36. I would go with yours, how could you have a high...

    I would go with yours, how could you have a high heat loss in Florida?
    I use cool calc, and just stick with 400 CFM per ton.
    You could always sign a waiver, and get the 2.5 ton, and be more...
  37. Had enough of the pressure switch expert?...

    Had enough of the pressure switch expert? :whistle:
  38. Replies
    26
    Views
    2,329

    I was about to say the same thing, even with a...

    I was about to say the same thing, even with a joint, who knows if someone might stick a broom in there?
  39. Thread: Really

    by EugeneTheJeep
    Replies
    8
    Views
    425

    :grin2:

    :grin2:
  40. Replies
    21
    Views
    747

    That would never be a leak tite joint in my book....

    That would never be a leak tite joint in my book. Fill that sucker in.
  41. So, did it shut down the air handler and...

    So, did it shut down the air handler and condenser when it had a leak? I believe what you said in your OP, is that it shuts down the entire system, as if its satisfied?
  42. Did you try and put another another known good...

    Did you try and put another another known good thermometer right next to the control? I have seen these units with a HP switch opening, and it definitely sounds the error back to the controller. If...
  43. Thread: Really

    by EugeneTheJeep
    Replies
    8
    Views
    425

    Aw Gawd! Get over it. :whistle:

    Aw Gawd! Get over it. :whistle:
  44. Why not just hook up the gas, and charge it to 5...

    Why not just hook up the gas, and charge it to 5 degrees F, SH in cooling?
  45. Replies
    10
    Views
    447

    Where are you even getting flex? All my suppliers...

    Where are you even getting flex? All my suppliers say its unavailable, and even the online sources have none in stock.
  46. With 6 units, on rough terrain, a crane could do...

    With 6 units, on rough terrain, a crane could do them all very easily.
    I used to work on some Cingular cell tower units, so I know what you are up against.
  47. Thread: Ashamed

    by EugeneTheJeep
    Replies
    40
    Views
    2,481

    Yes, that is because you can't find a new one,...

    Yes, that is because you can't find a new one, and it's driving up the prices of used.
    Fook Joe Biden!
  48. Thread: Ashamed

    by EugeneTheJeep
    Replies
    40
    Views
    2,481

    A cap for the pickup would be a big plus.

    A cap for the pickup would be a big plus.
  49. Thread: Ashamed

    by EugeneTheJeep
    Replies
    40
    Views
    2,481

    Its the long tall Transit, 13' long bed, and I...

    Its the long tall Transit, 13' long bed, and I keep a 24 ext ladder inside.
  50. Thread: Ashamed

    by EugeneTheJeep
    Replies
    40
    Views
    2,481

    I can' help you if you don't charge enough. i got...

    I can' help you if you don't charge enough. i got to the point where I don't want to run anymore. So the piddly calls, I tell them a week or two if I am on big money making jobs, some wait, and some...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4