Search:

Type: Posts; User: mo-flo

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Thread: Ashamed

    by mo-flo
    Replies
    40
    Views
    2,325

    utility bed was route i went with my pickup truck

    utility bed was route i went with my pickup truck
  2. Replies
    20
    Views
    781

    safe bet on 22 i would assume....i get in trouble...

    safe bet on 22 i would assume....i get in trouble every time i ASS U ME tho....
  3. Replies
    20
    Views
    781

    nordyne....looks like Miller manufactured housing...

    nordyne....looks like Miller manufactured housing brand to me
  4. Replies
    20
    Views
    781

    looks like gibson unit....nordyne product

    looks like gibson unit....nordyne product
  5. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    yes sir....i plan on being a sponge for knowledge

    yes sir....i plan on being a sponge for knowledge
  6. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    thank you....helps alot

    thank you....helps alot
  7. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    ahu's are on a schedule of operation....all he...

    ahu's are on a schedule of operation....all he told me,and that mixed air damper position prevents cooling valve from actuating....something about dampers are slow and they don't want to make...
  8. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    ahu's are on a schedule of operation......i'll...

    ahu's are on a schedule of operation......i'll learn more as i go....it will be ok
  9. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    When ahu first kicks on it locks out chw valve...

    When ahu first kicks on it locks out chw valve for first 20 minutes until outside air dampers settle into their position.....is what i foind out from my supervisor yesterday
  10. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    thank you for your service.....i hope to follow...

    thank you for your service.....i hope to follow in a similar path as you....eventually one day myself....Good Lord willing!
  11. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    Awesome!.....yeah i'm seeing what you mean.....i...

    Awesome!.....yeah i'm seeing what you mean.....i gotta do readings every 2 hours on boilers and chillers....get a visual on cooling tower.....then back up the stairs to control room to watch 3...
  12. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    the benefits and stability is main reason i took...

    the benefits and stability is main reason i took this position......pick and choose what residential i want to fool with in my spare time is game plan
  13. Replies
    14
    Views
    1,163

    first thing i was taught.....going in peoples...

    first thing i was taught.....going in peoples homes you clean up your mess and then some....doesn't matter if trash was ours or Not....we were expected to be THE CLEANEST IF WE WEREN'T THE BEST HVAC...
  14. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    not that i'm aware of.....been here 6 months and...

    not that i'm aware of.....been here 6 months and nothing has been mentioned about it.....none of the other guys are......maybe because it's a state university?......i think that exempts us from...
  15. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    so far so good.....alot of fresh air intake and...

    so far so good.....alot of fresh air intake and exausted airflow i need to get better versed at understanding......as well as my primary and secondary loop theory
  16. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    i just released overide.....see if it goes back...

    i just released overide.....see if it goes back into alarm on me now
  17. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    not to mention instead of steam....they use high...

    not to mention instead of steam....they use high tempature high/ pressure water for heating........right now i have an alarm for high discharge air at 75 on an air handler at a building......so i put...
  18. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    blows me away what they are doing with water...

    blows me away what they are doing with water chilled 10 degrees....and the distance they are pumping it is unbelievable
  19. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    LOL....:grin2:

    LOL....:grin2:
  20. Thread: Big Change.....

    by mo-flo
    Replies
    29
    Views
    1,427

    Big Change.....

    SO....i'm spending my day with you from a control room overseeing 6 chillers and 4 boilers.....which is something as a residential hvac guy i never dreamed of doing....but here i am with you guys to...
  21. Replies
    132
    Views
    6,118

    Poll: lisc. contractors go out of business...

    lisc. contractors go out of business too......alot of your low quality is due to budget/money issues as well......not just untrained unliscensed contractors
  22. Replies
    132
    Views
    6,118

    Poll: no is my answer......free market will police...

    no is my answer......free market will police itself
  23. Replies
    132
    Views
    6,118

    Poll: no state lisc. in illinois.....only roofers and...

    no state lisc. in illinois.....only roofers and plumbers.......the way they look at it is......free market will weed out the hacks itself......if your work is subpar....you won't be in business long...
  24. Replies
    3
    Views
    758

    I'll get back with you guys when I have more info

    I'll get back with you guys when I have more info
  25. Working in a similar position now at a university...

    Working in a similar position now at a university campus....have to say...night and day difference from residential hvac
  26. Replies
    14
    Views
    2,842

    can't use pvc for popoff valve...

    can't use pvc for popoff valve discharge......atleast where i'm at
  27. Replies
    3
    Views
    758

    carrier o2xr issue....

    they think it'S A MOTOR....put a megger on it and checked good.......anyone have experience with these?
  28. Replies
    9
    Views
    1,174

    Definitely doesn't pay to report your...

    Definitely doesn't pay to report your symptoms...I'm finding that out
    No good deed goes unpunished...smh
  29. Replies
    7
    Views
    950

    Not sure the brand...it has an expansion...

    Not sure the brand...it has an expansion tank,pump,and controls board pre-assembled in one panel that distributes water to heating coil or cooling coil as well as domestic hot water....water lines...
  30. Replies
    9
    Views
    1,174

    It's a tough situation for sure...I don't want to...

    It's a tough situation for sure...I don't want to spread the virus around or infect nobody with it...I'm still trying to figure out how,when and where I picked it up...especially being vaccinated and...
  31. Replies
    9
    Views
    1,174

    Could of worked today...

    I feel better...but...unfortunately I'm off till Tuesday after testing positive for covid...seems like a person should be able to receive some compensation for lost hours if they can work but CDC...
  32. Replies
    7
    Views
    950

    They were talking about hooking solar panels up...

    They were talking about hooking solar panels up to run it...thus taking bill down to nothing...🤔😯
    I used to be a die-hard gas-fired forced air man for heating...but I'm warming up to this closed...
  33. Replies
    7
    Views
    950

    Air to water heat pumps....

    Just to watch the show on Bob Vila at these things on there and they look pretty cool you can do and domestic hot water said the customers bill went from 3000 to 1000 after installation
  34. Thread: Hazard pay?

    by mo-flo
    Replies
    11
    Views
    1,027

    So...uv light should be installed in filter...

    So...uv light should be installed in filter section of air handlers to kill any covid particles the filters catch is what I'm hearing...but the amount of air moved is most likely moved at too high of...
  35. Thread: Hazard pay?

    by mo-flo
    Replies
    11
    Views
    1,027

    Hazard pay?

    Watch out boys and girls it's in the air or the ductwork 1.....I'm vaccinated and still caught covid...
    Anyways I'm working on these huge air handlers now that you literally walk inside of to chan%...
  36. Replies
    35
    Views
    2,532

    lol...ok..👍

    lol...ok..👍
  37. Replies
    35
    Views
    2,532

    Trane chiller at physical plant and air handler...

    Trane chiller at physical plant and air handler showing 3 of the 6 doors on it located in.penthouse of one of several buildings
  38. Replies
    35
    Views
    2,532

    See if this works?

    See if this works?
  39. Replies
    35
    Views
    2,532

    Thanks

    Thanks
  40. Replies
    35
    Views
    2,532

    These doors are more like doors on ships that I'm...

    These doors are more like doors on ships that I'm working on...not quite 16 foot big
  41. Replies
    35
    Views
    2,532

    ok...I'll see if I can download it

    ok...I'll see if I can download it
  42. Replies
    35
    Views
    2,532

    thanks man for the words of encouragement

    thanks man for the words of encouragement
  43. Replies
    0
    Views
    798

    Sad to hear the news...

    Prayers and condolences to friends and family members of the members of this site that have passed....some of these names I'm reading were members that really helped me along alot on here
  44. Replies
    20
    Views
    1,825

    O2 will rise and so will CO from flame...

    O2 will rise and so will CO from flame impingement....afterblower comes on...it takes a little time for heat to open up breach in heat exchanger...no more than 100 ppm CO in flue gas...if so...needs...
  45. Replies
    35
    Views
    2,532

    I wish I could figure out how to upload pictures...

    I wish I could figure out how to upload pictures from .y phone on here
  46. Replies
    35
    Views
    2,532

    I think some engineers came out to look at...

    I think some engineers came out to look at putting some uv lights in and they said we have about 30 or so air handlers that u can walk in like that....the air handlers I'm maintaining now are the...
  47. Replies
    35
    Views
    2,532

    Disregard.

    Disregard.
  48. Replies
    35
    Views
    2,532

    hvac talk is only place I've ever came to..."to...

    hvac talk is only place I've ever came to..."to talk shop"
  49. Replies
    35
    Views
    2,532

    went thru a divorce after 25 years....damn near...

    went thru a divorce after 25 years....damn near killin' me...it's not been pretty at all for me
    Business has gotten down to nothing..so...I went and got a job at a university doing hvac for them...
  50. Replies
    35
    Views
    2,532

    2017

    2017
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4