Search:

Type: Posts; User: mrcool

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Just why?

    by mrcool
    Replies
    18
    Views
    1,171

    is that and outlet in the supply? Duct shoe...

    is that and outlet in the supply? Duct shoe Rack--- im putting that as an option on all my installs
  2. Replies
    44
    Views
    11,197

    my top three ice machine- 1. hoshizaki 2....

    my top three ice machine- 1. hoshizaki 2. hoshizaki 3. hoshizaki --- i saw this post was old but they probably need a new ice machine by now
  3. worked on only two of those units and both had...

    worked on only two of those units and both had that problem
  4. Thread: Lowest bidder

    by mrcool
    Replies
    15
    Views
    1,226

    maybe the installer was trying to express his...

    maybe the installer was trying to express his artistic side.
  5. Replies
    21
    Views
    9,449

    what about clocking the gas meter

    what about clocking the gas meter
  6. Replies
    29
    Views
    1,254

    https://www.coolairproducts.net/fixquick/ --- ...

    https://www.coolairproducts.net/fixquick/ --- was at trane today and saw this
  7. Replies
    111
    Views
    3,099

    check preasure at discharge and at receiver-- i...

    check preasure at discharge and at receiver-- i do the touch test to and had one fool me onces
  8. Replies
    24
    Views
    1,146

    i owe them 8 fingers after i picked up a tank of...

    i owe them 8 fingers after i picked up a tank of 134a, anybody have some fingers they can spare
  9. Replies
    51
    Views
    1,882

    most of the refrigerant today are made of a...

    most of the refrigerant today are made of a mixture of refrigerants---so now if ur mixing r22 and MO99-- ur only making ur own custom mixture ----LOL
  10. Replies
    14
    Views
    886

    as far as UL ratings go -- they are useless, like...

    as far as UL ratings go -- they are useless, like the dolphin free stamp on tuna can , had my TV screen catch on fire, when i reported it to them they didnt do nothing about it, even to put out a...
  11. Replies
    14
    Views
    886

    little giant, the float was not working pump- was...

    little giant, the float was not working pump- was running dry- but i installed a pump with a power cord cause there was a outlet near by- but hav e u ever cut the cord and connected it to the wall...
  12. i dont think anything with R290 wound be a good...

    i dont think anything with R290 wound be a good replacement-- think about how much refrigerant is in that thing and 4 5 years down the line there a pinhole in the evap or it could be in the condenser...
  13. Will that work?

    Will that work?
  14. Replies
    14
    Views
    886

    condensate pump for mini split

    Had to replace a mini split condensate pump, making a lot of noise and the guy thats in the next room to servers was complaining. so this was a mini 2 piece pump and i replaced it wth a a regular...
  15. Replies
    13
    Views
    1,468

    wanted to lighten the load on the toolbag to so i...

    wanted to lighten the load on the toolbag to so i got this...
  16. i have installed three mitsubishi city multi(2...

    i have installed three mitsubishi city multi(2 10 tons and 1 71/2 Ton) in a room maybe 7'x14' with 2 window ,this was for an office, can tell u that condenser need to be cleaned every year, havent...
  17. Replies
    16
    Views
    4,846

    i stayed at a hotel in clearwater florida that...

    i stayed at a hotel in clearwater florida that had baseboard running around the ceiling that had chilled water ( i assume ) and a gutter to collect the condensation, never seen that before and have...
  18. Replies
    1
    Views
    1,417

    bakers pride thermostat

    anybody know the difference between the fdth-1-03-36 and fdth-1-04-48?
  19. did u check the evap motor and blade, maybe they...

    did u check the evap motor and blade, maybe they were replaced ? once had a masterbilt freezer with a 115 v defrost heater instead of 208v heater from the factory.. causing to much heat during...
  20. Replies
    1
    Views
    958

    Trenton fractional HP condensing unit

    Has anyone used this brand ? i think it uses a Aspera compressor.
  21. Replies
    44
    Views
    6,690

    looking for a helper

    need someone that can follow me around with a van to carry all the refrigerants i need, i have no more room in my truck.
  22. Replies
    13
    Views
    1,721

    i thought Flip flops were mandatory in florida

    i thought Flip flops were mandatory in florida
  23. Pecmsg-- wow havent seen that in years, we did an...

    Pecmsg-- wow havent seen that in years, we did an A&P supermarket that had the whole store on those things, changed alot of belts in that store-- never seen the three speed evap before, is it...
  24. replaced a copeland semi herm last month with a...

    replaced a copeland semi herm last month with a 69 serial- 51 years old, it cracked the vibration absorber, LPC got stuck in closed position and ran for a day with no gas. seized up probably would ...
  25. Replies
    23
    Views
    2,327

    two 5hp and a one 7 1/2hp, i think someone...

    two 5hp and a one 7 1/2hp, i think someone made some big modification on it, the tag says 40 hp
  26. Replies
    23
    Views
    2,327

    whats wrong with putting poe in a copeland semi

    whats wrong with putting poe in a copeland semi
  27. Replies
    23
    Views
    2,327

    Old Hill rack retrofit

    Got a customer that has old 502 rack that was converted to hp80, one LT comp and 2 MT Comp, i add maybe 15 pounds a year, stand-by reserve down to 10 lbs and hp80 expensive, was thinking of...
  28. Replies
    8
    Views
    1,767

    Rebuilt compressor

    Cmp , A1 remanufactured compressor or rebuilt by oem, has anybody tried cmp rebuild, i have tried the national compressor out of ny and woundnt recommend
  29. Replies
    9
    Views
    1,472

    what r u using for aluminum coil repair

    with all the aluminum being used now for condenser and evaps, what products r u using to repair them, when i first started epoxy was the only thing.
  30. Replies
    0
    Views
    576

    temp alarm for walkin

    need recommendation on a temp alarm for walk in , has anybody tried the sensorpush
  31. 2+ on the drier, had one like that with no temp...

    2+ on the drier, had one like that with no temp drop across drier, but when i removed it , boy was it plugged , i had ordered the piston manifold just in case the drier wasn't clogged, probably good...
  32. Replies
    3
    Views
    1,213

    Lddc, first time i went there DA was set at 65,...

    Lddc, first time i went there DA was set at 65, lowered it to 50 and second stage (comp 2+3) ran for ten min , then back to first stage , did the test it runs fine , checked pin from board and...
  33. Replies
    3
    Views
    1,213

    Trane voyager YCH600

    trane unit seem to be in default mode, i lowered the DA setpoint, lowered space temp and only first stage runs, no flashing at rtrm, tried to put a conventional tstat on rtrm but it wound not work...
  34. Replies
    3
    Views
    1,473

    liskey aire vk20-4600

    anybody have any info for this unit, is this company still in business?
  35. anybody have any tricks to cleaning condenser coils?

    i have a condensers coil that is about 8 inches thick and has been a problem to clean, i have removed condenser blades and cleaned from both ends and still cant get it clean enough, any idea wound...
  36. jimp, looks like a schrieber chiller

    jimp, looks like a schrieber chiller
  37. Replies
    69
    Views
    8,670

    iQuote Originally Posted by timebuilder View...

    iQuote Originally Posted by timebuilder View Post
    If you alter the overcurrent device type (from fuse holder to din rail breaker) you are:

    1) invalidating the UL listing for the equipment, and
    ...
  38. Replies
    69
    Views
    8,670

    the 30 amp fuse r rated for 600v and the 60 amp r...

    the 30 amp fuse r rated for 600v and the 60 amp r 480v, wire gauge on the 30 amp i think is #10 and the 60 amp is at lease #8 or #6 , i dont think it's the wire. i noticed the the fuse holder clip is...
  39. Replies
    69
    Views
    8,670

    I replaced one with a new fuse holder and the new...

    I replaced one with a new fuse holder and the new one was also getting hot thatís why I was thinkiing of putting breakers and the only thing bad about that is when it trips I lose all power to...
  40. Replies
    69
    Views
    8,670

    defrost heater fuses blowing

    working on a krack freezer unit SM24 evap and there are 12 30amp fuses and 12 60amp fuses that supply the defrost heater, the 30 amp fuses are drawing 21 amps and the 60 amp fuses are drawing 41...
  41. Replies
    6
    Views
    1,925

    Data aire thermostat

    working on a data aire dama-0212 with a mini dap ii thermostat, tstat went blank, need new so i call data aire and tstat needs to be upgraded for a unit that is only 7 years old, so i need a kit...
  42. Replies
    3
    Views
    1,509

    i had crossed a wire, its working thanks

    i had crossed a wire, its working thanks
  43. Replies
    3
    Views
    1,509

    no, i made the cable from a 9pin cable and a 25...

    no, i made the cable from a 9pin cable and a 25 pin cable
  44. Replies
    3
    Views
    1,509

    andover infinity

    does anybody know how to directly connect to an andover infinity , i tried a 9 pin to 25 pin cable , pin out 7-7, 2-2, 3-3, and the hyperterminal freezes,
  45. Replies
    4
    Views
    3,360

    apparently this control needs a transformer that...

    apparently this control needs a transformer that has no voltage reading from common on transformer to ground or neutral on lcx810.
  46. Replies
    4
    Views
    3,360

    i have no wiring connected to lcx810. i just...

    i have no wiring connected to lcx810. i just have power connected
  47. Replies
    4
    Views
    3,360

    andover infinity lcx-810 Help

    i got an old andover lcx-810, the output relays have failed, computer say on lites on lcx output come on but nothing happening, so i buy a used one install, load program everthing looks ok...... not....
  48. Replies
    2
    Views
    2,167

    kysor warren lv5h

    anybody ever work on this case and how are they, a customer of mine just got these cases installed, these were refurbished cases. water lays in the case and freezes over the drain, installed drain...
  49. Replies
    5
    Views
    1,949

    andover infinity

    can you use hyper terminal to back up andover infinity, i ve tried to use it but cant seem to get it done, i have the pdf on "andover programing" it explains it using comm talk, the pdf doesnt say...
  50. Replies
    3
    Views
    1,750

    Andover infinity backing up

    i am having a problem trying to backup andover ,i have the andover programers guide and i cant figure it out, cant someone tell me how to back up and reload files
Results 1 to 50 of 201
Page 1 of 5 1 2 3 4