  1. Replies
    2
    Views
    666

    Tecumseh help

    Can anyone tell me if the AE1126E-106-J7 compressor is a good replacement for the AE560AT-916-J7. As I found the latter in a unit that should have the first and we are having issues with the unit.
    ...
  2. Replies
    20
    Views
    645

    Disconnect the fans while checking SH? Why?...

    Disconnect the fans while checking SH? Why? Ohhhhhh, in a cooler it's evaporator temp, smart thinking!
  3. Not sure if you are asking me but I believe this...

    Not sure if you are asking me but I believe this is an indigo and the charge is on the nameplate. 12.5 Pounds of 404A.
  4. I could see the discharge temperature sensor was...

    I could see the discharge temperature sensor was an available accessory but not the injector. Is that because it doesn't have the injector port stub? Anyone have any luck using this type compressor...
  5. Replies
    21
    Views
    2,393

    Can not remember the type of unit I ran into a...

    Can not remember the type of unit I ran into a couple months ago, was a ten door display with an outdoor condenser, did not have a headmaster or receiver and was critically charged to run that way....
  6. Replies
    21
    Views
    2,393

    Charge it to 90% of receiver capacity of the...

    Charge it to 90% of receiver capacity of the refrigerant it's designed to use.
    Since no headmaster you better add a fan delay.
  7. With what compressor model?

    With what compressor model?
  8. Replies
    100
    Views
    37,640

    lol

    lol
  9. Replies
    44
    Views
    11,197

    2013 thread. Haha

    2013 thread. Haha
  10. It's already been said . Nitrogen will help move...

    It's already been said . Nitrogen will help move it along. one of the reasons you do a triple evac with it.
  11. Replies
    13
    Views
    2,651

    ???

    ???
  12. Replies
    100
    Views
    37,640

    Watch out , VTPs finders fees are outrageous.

    Watch out , VTPs finders fees are outrageous.
  13. Mad respect bro.

    Mad respect bro.
  14. Thread: 448-404

    by Gary Warren Jr
    Replies
    20
    Views
    1,186

    It's cost a lot of customers money for sure....

    It's cost a lot of customers money for sure. Wondering why their AC doesn't cool and no one can fix it. That is till I come and pull all that crap out and put in clean refrigerant. I have seen...
  15. Thread: 448-404

    by Gary Warren Jr
    Replies
    20
    Views
    1,186

    This right here. Lol

    This right here. Lol
  16. I do not think I have ever had one go acidic just...

    I do not think I have ever had one go acidic just having system opened up. If that was the case I would think you would need one on every system opened up.
  17. 210PSIG at the outlet of your evap is definitely...

    210PSIG at the outlet of your evap is definitely a problem haha. Sounds like it's running straight through your TXV with no metering at all. Or your valves are shot which I doubt since you said you...
  18. Replies
    13
    Views
    402

    Exactly what it was!

    Exactly what it was!
  19. That model# for that unit says it's a medium to...

    That model# for that unit says it's a medium to high temp condensing unit. You will not be able to use it for freezer without modifying it.
  20. ZS21KAE-TF5 is the model# of that compressor in...

    ZS21KAE-TF5 is the model# of that compressor in that unit. And that is either a high or medium temp compressor. That just may be his issue , good point.
  21. Danfoss are e pensive. At that price they come...

    Danfoss are e pensive. At that price they come quth the sensors to ,I believe.
  22. Replies
    13
    Views
    402

    I seen a pair of 2 ton window shakers last over 4...

    I seen a pair of 2 ton window shakers last over 4 years last I seen them working they were still humming. Some bar owner made his own. One of the AC units was just a backup in case something happened.
  23. Replies
    13
    Views
    402

    Seen this done quite a few times with window...

    Seen this done quite a few times with window shakers too. Used so ethi g similar to the ke2 but a lot cheaper. Had a sensor for evaporator and a lead that warmed the thermostat on the shaker to fool...
  24. can you slowly recover all the charge out of the...

    can you slowly recover all the charge out of the condenser line set through the liquid line at the receiver? I can't see anything that would stop it from recovering, may be slower but that's it....
  25. I can not tell you how much you made my morning...

    I can not tell you how much you made my morning when I read this. I feel so foolish for not thinking of this.
  26. This is what I love, the brainstorming on here!...

    This is what I love, the brainstorming on here! Why I did not think of this is beyond me. TY TY TY! I do have two but why do that when I can solder an access fitting on, THANK YOU!

    I was really...
  27. A 500 micron triple evac will take care of it.

    A 500 micron triple evac will take care of it.
  28. Just pull the charge and do a triple evac down to...

    Just pull the charge and do a triple evac down to 500 microns. If it doesn't hold under 700 I would pressurize it with nitrogen to design pressure of evaporator and see if it holds after it...
  29. Replies
    57
    Views
    1,058

    My fieldpiece measures grams and ounces down to...

    My fieldpiece measures grams and ounces down to the .01 ounce. I have charged an

    R 600 wine cooler had under 3 ounces.
  30. What if I can't get to the access fitting in the...

    What if I can't get to the access fitting in the back. Any suggestions? Will I be able to vacuum one side and then the other from the roof? Why don't you recommend it other than all the extra work?
  31. Replies
    57
    Views
    1,058

    What are your pressures after adding when box was...

    What are your pressures after adding when box was at temp?
  32. Then I will have to somehow pull this monster...

    Then I will have to somehow pull this monster from the wall to get to them as they are pointed down and not accessible as this thing is. And I hope I can get them on after I get it out as I may have...
  33. I went ahead and reused the R12 and enjoyed the...

    I went ahead and reused the R12 and enjoyed the weekend after.
  34. Looking at this refrigerant cycle I should be...

    Looking at this refrigerant cycle I should be able to front seat the king valve on the receiver and
    use the check valve on the discharge line to evacuate the head charge to change the harvest...
  35. Replies
    6
    Views
    669

    I usually leave pan on and drain into a trashcan...

    I usually leave pan on and drain into a trashcan if it's so bad your scared to clog drain. I have several different 3/4" drain pieces to hookup for this.
  36. Replies
    22
    Views
    4,848

    Evacuate and recharge with plate charge. Good...

    Evacuate and recharge with plate charge. Good luck.
  37. Sounds like a bad on off switch making and...

    Sounds like a bad on off switch making and breaking causing it to repeat the beginning purge over and over.
  38. Manitowoc Indigo harvest valve replacement

    Model# ID1892N-261D
    Serial# 1120037458
    Remote unit.

    Harvest valve sticking . I done an evacuation using just the high and low side that is accessible from the front and only got 15 ounces and...
  39. Replies
    36
    Views
    2,439

    Do you have to change anything other than...

    Do you have to change anything other than refrigerant to convert?
  40. they have similar pressures

    they have similar pressures
  41. WHo is RSL? United did not have it. Do you...

    WHo is RSL? United did not have it.

    Do you all think hotshot would work in this? I have that. Opinions on Hotshot? I used to hear it had a high head, why they called it hot shot , lol
  42. I have been searching online for it and can't...

    I have been searching online for it and can't find anyone. You got a name local that sells it?
  43. ya, for sure

    ya, for sure
  44. Its a 3 door with on top condensing unit,...

    Its a 3 door with on top condensing unit, ambient stays around 75-80 max
  45. LRA on compressor thinking of pulling the charge...

    LRA on compressor
    thinking of pulling the charge and just recharging it with the same charge after what I am hearing here.
  46. Replies
    28
    Views
    4,242

    That's an interesting fact!

    That's an interesting fact!
  47. Replies
    28
    Views
    4,242

    Ya I knew not to use nickel safe on them. Thanks...

    Ya I knew not to use nickel safe on them. Thanks bro.
  48. R12 Comnpressor B81-784 Tecumseh conversion to 404A

    I have an old 3-door freezer, R12 system that is TXV fed. The compressor went bad but I have that same compressor, the B81-784 charged with alkylbenzene oil . Can I convert this to 404A by changing...
  49. Replies
    18
    Views
    14,731

    I have an R12 3 door freezer unit that the...

    I have an R12 3 door freezer unit that the compressor went out of, can I use an R134A compressor I have of the same size and convert it to use 404A by changing the powerhead on the TXV?
  50. It can get pretty warm if the captube is soldered...

    It can get pretty warm if the captube is soldered to it for heat transfer.