Search:

Type: Posts; User: ACxpert

Search: Search took 0.01 seconds.

  1. Replies
    0
    Views
    1,054

    B&G Pumps for sale

    Bell & Gossett E34V/Bspyz Pump. Brand new, never used. Perfect for hot water circulation and other uses. Super quiet, has built in thermostat and 1/2 sweat connections. $250 new, yours for $200.
    ...
  2. Replies
    10
    Views
    673

    I have seen this happen before. I came across a...

    I have seen this happen before. I came across a Vista system that had a corrupted front end and apparently the installing contractor never made a clean backup of the LNS database. Even though the job...
  3. Replies
    34
    Views
    4,371

    I know its a long shot, but have you tried...

    I know its a long shot, but have you tried blowing out the pilot tubing and carefully inspecting the pilot orfice? Sometimes spiders will lay eggs inside the tubing, its not enough to stop the gas...
  4. Replies
    15
    Views
    3,263

    Extra Cooling....

    In 35 years Ive seen alot but this is a first....811116
  5. Replies
    2
    Views
    489

    Barry Blower Information

    Does anyone happen to have an old Barry Blower catalog circa 1972? Size 7365, Arr 3-CCW-THD Type AF-DW, SN 72-4450. I checked with rep and they called the factory and apparently they no longer have...
  6. Replies
    9
    Views
    1,770

    Funny, I installed a unit heater in my garage and...

    Funny, I installed a unit heater in my garage and the fan noise drove me nuts. Should have installed an infra red heater, oh well....
  7. Replies
    30
    Views
    15,314

    Sorry I sold the controllers a long time ago but...

    Sorry I sold the controllers a long time ago but I do still have the Hand Held Controller. This device is needed to address the PCU's, etc.

    Make me an offer I cant refuse....
  8. Replies
    24
    Views
    14,031

    Have you talked to York about the issue? I would...

    Have you talked to York about the issue? I would imagine you are not the only one experiencing this problem and they may have some recommendations for you to try. Is the problem worse in heating than...
  9. Replies
    69
    Views
    6,954

    This is a real longshot, but reminds me of a real...

    This is a real longshot, but reminds me of a real unusual situation I encountered many moons ago. I replaced a couple of water cooled chillers on a large department store. Both new chillers were...
  10. Replies
    50
    Views
    2,923

    Also, which "limit switch" is it tripping on?

    Also, which "limit switch" is it tripping on?
  11. Replies
    12
    Views
    8,840

    Shutting down the pumps when not needed would...

    Shutting down the pumps when not needed would absolutely make sense as an energy savings measure, but in the case of a retrofit it can be expensive. As others have mentioned, there needs to be an...
  12. Replies
    37
    Views
    3,133

    A few of the reasons I have refused to work on...

    A few of the reasons I have refused to work on customer equipment:

    1. Unsafe roof ladder.
    2. Unsanitary conditions (rat droppings)
    3. Unsanitary conditions (pigeon droppings)

    #1 is a no...
  13. Replies
    14
    Views
    3,174

    Many moons ago when I was a young tech I went on...

    Many moons ago when I was a young tech I went on a service call for no heat. The furnace was a Bryant Horizontal in the rafters above the garage. There was obvious flame roll out as the wires and...
  14. Replies
    12
    Views
    8,684

    Was going through the garage today and came...

    Was going through the garage today and came across the TAC 7410 Hand Held controller. Make me an offer I cant refuse.......
  15. Replies
    9
    Views
    4,729

    Sorry, they are gone.

    Sorry, they are gone.
  16. Replies
    12
    Views
    8,684

    Just the CPS, H10's and HHC are left......

    Just the CPS, H10's and HHC are left......
  17. Replies
    12
    Views
    8,684

    Been out of the field for a while, nothing...

    Been out of the field for a while, nothing personal....
  18. Replies
    12
    Views
    8,684

    Yes it works. The terminals are fine, no...

    Yes it works. The terminals are fine, no corrosion as I took the batteries out a long time ago.....
  19. Replies
    12
    Views
    8,684

    HVAC Tools for sale

    TAC HHC 7410 Handheld Tool $200.00

    http://i855.photobucket.com/albums/ab113/rboe2/IMG_0365_zps1f4eaba1.jpg?t=1378333233

    Tif Refrigerant scale, model 9010A. Like new, barely used like new...
  20. Replies
    9
    Views
    4,729

    They are still available.PM me your contact info...

    They are still available.PM me your contact info and we can go from there.

    Thanks.
  21. Replies
    9
    Views
    4,729

    Novar stuff for sale

    The below items are still available.......


    (1) Processing Modem V1.09 with RS232 cable and (2) transformers
    (1) Sitepro type 3 Pic
    (1) PC RS232 cable
  22. Replies
    5
    Views
    3,316

    Staefa Controls support

    Does anyone know if the 1993 vintage of Staefa controls is still supported? I believe the controllers are "smart II". There is no front end or network controllers, the last tenant must have walked...
  23. Replies
    0
    Views
    621

    Tracer Summit Questions

    I have a site that we are adding some new Trane VAV's, an Intellipak unit and heating unit. It is 1999 vintage and has (2) BCU's, model BMTS with lots of numbers after it.

    I am looking for a PCM,...
  24. Replies
    0
    Views
    838

    Looking for a Trane TCM

    Please contact me if you have a good Trane TCM board available for sale.

    Thanks,

    Rich
  25. Replies
    53
    Views
    30,120

    I will never forget many moons ago as an...

    I will never forget many moons ago as an apprentice I was changing out a leaky pump on an Amana HTM furnace and when I was done I turned on the power and all of the power in the house went out. It...
  26. Replies
    9
    Views
    4,729

    Please send me an email and we can discuss. My...

    Please send me an email and we can discuss. My email is in my profile.

    Thanks.
  27. Replies
    9
    Views
    4,729

    Novar stuff for sale

    I have the following Novar items available:

    (1) Processing Modem V1.09 with RS232 cable and (2) transformers
    (1) Sitepro type 3 Pic
    (1) PC RS232 cable

    Make me a reasonable offer and they are...
  28. Replies
    0
    Views
    1,097

    Johnson Metasys stuff for sale

    I have the following stuff available:

    (1) VMA 1410 VAV box controller new in the box
    (2) VMA 1420 VAV box controller new in the box
    (2) N30 controller used

    Make me a reasonable offer and they...
  29. Replies
    6
    Views
    1,467

    Looking for a used or new chiller

    I am looking for a used or new water cooled chiller in the 600 ton range, 460v, preferably 134a.

    Thanks,

    Rich
  30. Replies
    3
    Views
    1,099

    The company I used to work for had a plan that...

    The company I used to work for had a plan that was 100% incentive and had pretty much the same plan for mechanical, service and controls folks. The typical PM would draw ~ 2K per week and would get a...
  31. Replies
    11
    Views
    3,479

    Turbocor

    Great idea, but, they have a VERY high failure rate. Very high learning curve. Be careful......
  32. Replies
    0
    Views
    718

    Seeking PM/Sales position in SF Bay Area

    Experienced (24 years) HVAC Professional seeking a service/retrofit/sales, project management or operations position in the San Francisco Bay Area.

    Excellent references and work history, please...
  33. Replies
    1
    Views
    1,003

    Energy Savings calculators

    I am looking for a calculator to estimate the energy savings that will result by changing out old commercial rooftop units to new high seer units. The units are all constant volume. Does not have to...