Search:

Type: Posts; User: dave sulz

Page 1 of 11 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    23
    Views
    2,168

    We have a industrial combustion burner from the...

    We have a industrial combustion burner from the 80s has one of those in a cleys Hayward pressure proving switch
  2. Replies
    9
    Views
    858

    I have had crossed wires causing icing when not...

    I have had crossed wires causing icing when not all heads are calling.
  3. Replies
    6
    Views
    521

    In NJ I have used mcn distributors. Also...

    In NJ I have used mcn distributors. Also re-michaels
  4. Purge the empty manifold with the can on the...

    Purge the empty manifold with the can on the scale using liquid. That is what filled it up. I think. I Purge my hose with the can on scale all the time
  5. Replies
    12
    Views
    4,155

    I use United refrigeration

    I use United refrigeration
  6. Replies
    20
    Views
    3,215

    I use my turbo torch. No oxy. The big muffler...

    I use my turbo torch. No oxy. The big muffler size tip will heat it up nice
  7. I have used heater on 3/4 PVC drains in the attic...

    I have used heater on 3/4 PVC drains in the attic for many years. Never melted
  8. Replies
    16
    Views
    961

    I use my map gas.

    I use my map gas.
  9. Replies
    10
    Views
    889

    I have had places where we shortened it an inch...

    I have had places where we shortened it an inch or two
  10. I have also used r22 in gas lines to locate a leak

    I have also used r22 in gas lines to locate a leak
  11. Replies
    39
    Views
    3,744

    Turbo torch has a monster tip. I brazed a 50 ton...

    Turbo torch has a monster tip. I brazed a 50 ton txv with wet rags all around no problem. Oxy is a waste of time mostly. Everything has its advantages. 3in copper no problem
  12. Replies
    13
    Views
    1,027

    They make condensate evaporative pans

    They make condensate evaporative pans
  13. Thread: lunch ideas

    by dave sulz
    Replies
    79
    Views
    42,999

    I was on the road to many many miles in NJ and...

    I was on the road to many many miles in NJ and when my dispatches came at nite I would plan a sandwich spot that was a good deli. Sometimes nothing good along the way. Now I'm off the rode in a...
  14. Thread: Broilmaster

    by dave sulz
    Replies
    17
    Views
    13,164

    I'm using a broil king with two sides to cook...

    I'm using a broil king with two sides to cook different temps. It's huge and awesome
  15. Replies
    12
    Views
    1,904

    He should have cut a square out of the door like...

    He should have cut a square out of the door like the small breaker hole you see on some brands
  16. Replies
    20
    Views
    1,517

    Look for soft solder joints. U had them blow out...

    Look for soft solder joints. U had them blow out w r410
  17. Replies
    24
    Views
    1,699

    Muffler

    Muffler
  18. Replies
    24
    Views
    1,699

    If that's an old York they used a miggler

    If that's an old York they used a miggler
  19. Replies
    65
    Views
    4,103

    I used to get 2% commission on any sales. That...

    I used to get 2% commission on any sales. That was my incentive. After they stopped commission I didn't push to sell
  20. Cover the condenser until you have 130degrees...

    Cover the condenser until you have 130degrees condenser temp and read subcooling
  21. I rember back then you had to bring the flame...

    I rember back then you had to bring the flame sensor too. The counter guy never tells you that.
  22. Replies
    10
    Views
    1,975

    We had a 5 ton ammana rtu fall from the crane. It...

    We had a 5 ton ammana rtu fall from the crane. It hit the roof from up high. Lucky no one was hurt. The bottom of the unit had rails on only 2 sides not all 4. The shackles were on the corners. The...
  23. If it works fine in cooling how can there be...

    If it works fine in cooling how can there be contaminants. I would look at other things before recovering.
  24. Reversing valve

    Reversing valve
  25. Replies
    38
    Views
    4,150

    We did some prevailing wage state program...

    We did some prevailing wage state program changeouts and they required some wacky controls like that. I don't think anyone checked to see them work correctly
  26. Replies
    25
    Views
    1,810

    If the tstat senses hum then might over ride set...

    If the tstat senses hum then might over ride set point. Is this a communication equipment. If not should be easy to diagnose
  27. Replies
    23
    Views
    4,445

    Funny here in NJ it is r8. What about a unicorn...

    Funny here in NJ it is r8. What about a unicorn install where before the flex tube fit inside a 2x4 wall. The r8 is way fatter
  28. Replies
    18
    Views
    1,459

    After doing so risky dangerous things because I...

    After doing so risky dangerous things because I was young and wouldn't say no I now tell anyone I decide what I seem safe and will or won't do
  29. Replies
    25
    Views
    1,810

    Is the thermostat sensing humidity

    Is the thermostat sensing humidity
  30. Pvi has a terrible rep. The 2 250 gallon I manage...

    Pvi has a terrible rep. The 2 250 gallon I manage rotted out in about 7 years. The installer worked for pvi and said they suck
  31. Replies
    26
    Views
    1,952

    I may have missed how many ma was it

    I may have missed how many ma was it
  32. Replies
    26
    Views
    1,952

    Did you check micro amps in series with the flame...

    Did you check micro amps in series with the flame rod on light up
  33. Replies
    57
    Views
    7,946

    Correct me but I charged a big walking in summer...

    Correct me but I charged a big walking in summer with headmaster. Cleared the glass but didn't add an extra amount for winter. Giant box filled w/ bannanas. Added and working nice but no ice just not...
  34. Replies
    19
    Views
    1,711

    I have the malco 48" it works good for plenums....

    I have the malco 48" it works good for plenums. Makes a deciemt hem flange. The clamp bar is good
  35. Replies
    18
    Views
    1,726

    Lennox board waits for the pressure switch to...

    Lennox board waits for the pressure switch to open on off cycle from tstat to shut off inducer.
  36. Replies
    6
    Views
    1,132

    Maybe the breaker is making poor contact in the...

    Maybe the breaker is making poor contact in the panel and when the comp starts the voltage drops. Had that on a big daiken
  37. Replies
    9
    Views
    1,107

    York uses a limit in the supply.if it has a side...

    York uses a limit in the supply.if it has a side discharge cover it could be in there
  38. Replies
    7
    Views
    964

    We used oval pipe w/a hi love stack head on top I...

    We used oval pipe w/a hi love stack head on top I always use a 45 on top to connect flex and oval in the wall to the stack head on bottom. No one opens and closes.
  39. Replies
    7
    Views
    964

    That is called high low registers. You close the...

    That is called high low registers. You close the bottom for cooling and close the top and open bottom for heat. Cooling from above heating from below. I roughed in alot of town houses in the 90s with...
  40. Thread: York Furnace

    by dave sulz
    Replies
    6
    Views
    878

    I have that tool

    I have that tool
  41. Thread: York Furnace

    by dave sulz
    Replies
    6
    Views
    878

    If it is the one on the side of the burner rack I...

    If it is the one on the side of the burner rack I drill a hole in the side of the furnace to get my phillips in
  42. Iserviced a 50 ton Trane unit years ago it was a...

    Iserviced a 50 ton Trane unit years ago it was a vav system. It had what looked like a thermostat on the wall but it's setting said sa that's supply air temp. The guy kept setting it to 70. Never...
  43. Replies
    4
    Views
    630

    I think those screw on pressure switches have...

    I think those screw on pressure switches have Schrader ports in them. I have removed others in the past and they did. Trane experts I work on a bunch of voygers
  44. Replies
    15
    Views
    2,797

    I like the flat rate

    I like the flat rate
  45. Replies
    29
    Views
    3,323

    Why is tho ild gas cock still in. Violation in nj

    Why is tho ild gas cock still in. Violation in nj
  46. why didnt the rollout switch open

    why didnt the rollout switch open
  47. Try heating water for a pool

    Try heating water for a pool
  48. How do you think a compressor hat runs above...

    How do you think a compressor hat runs above freezing work below freezing. I hate nonsense. I'm not smart but recoconize dumbass. Sorry stupid should be told
  49. Thread: Oil to gas

    by dave sulz
    Replies
    35
    Views
    5,978

    We run PVC in the old chimney in new jersey

    We run PVC in the old chimney in new jersey
  50. Replies
    1
    Views
    538

    Pnumatics piping question

    Hello. I see in a hydronic unit ventilator the branch air comes in and goes to the low limit. Then to the ep relay. Outlet of relay to heat valve and damper actuator. Why didn't the branch air...
Results 1 to 50 of 527