  1. Returns are only kitchen & basement? Strange. ...

    Returns are only kitchen & basement? Strange.

    But if the kitchen return is directly off the furnace below it, it will be noisy with blower and air noise. A box with duct liner works great to...
  2. Replies
    15
    Views
    327

    Some Goodman 2 stage thermostats can't be...

    Some Goodman 2 stage thermostats can't be controlled by 2 stage thermostats. Only by the board in the furnace. One place I looked at online said the E will do 2 stage equipment.
  3. Replies
    9
    Views
    181

    There are some higher end panels that can help...

    There are some higher end panels that can help avoid overheating or overheating when the small zone is asking for heat or cool. Also helps if you have 2 stage equipment. We use a company called...
  4. Good message!

    Good message!
  5. Replies
    20
    Views
    788

    Survived the coil shortages this summer, now our...

    Survived the coil shortages this summer, now our AS distributor is hurting on S8s and S9s. Says not a component shortage from Mexico like some of the problem, just selling so many the factory can't...
  6. Replies
    4
    Views
    158

    Check out a Honeywell FC40 media. From what I can...

    Check out a Honeywell FC40 media. From what I can tell, mounts in existing filter grille. Various sizes.
  7. The "rain gutter" is factory. I've seen it on...

    The "rain gutter" is factory. I've seen it on other brands too.
  8. The opening is 14x18. Our distributor sells a...

    The opening is 14x18. Our distributor sells a transition to go from the opening to a 16x25 media air cleaner. Or for bigger furnaces, they had a 6" riser box and a transition that uses the little...
  9. See what the zone panel is? Did he really use an...

    See what the zone panel is? Did he really use an Evolution panel or one that doesn't communicate with the Bryant equipment?
  10. Replies
    6
    Views
    236

    I checked our rates last week. Gas at 95% furnace...

    I checked our rates last week. Gas at 95% furnace is about 1/3 of what the same amount of heat will cost out of a decent heat pump at 32 out. Guess my dual fuel is going to rest the old heat pump...
  11. We always blow straight up. If you elbow, you...

    We always blow straight up. If you elbow, you will have acidic condensate drip on your roof. My 95% has a "rain gutter" on the exhaust to route condensate in the flue and rain into the drain system.
  12. Does the sound go away if you unplug the sucker?

    Does the sound go away if you unplug the sucker?
  13. Replies
    10
    Views
    320

    Suitcase, hadn't heard that. I like it! 66db...

    Suitcase, hadn't heard that. I like it!

    66db is QUIET for a central air outdoor unit. Something gotta be related to the shaking which like pecmsg says, shouldn't be doing. Stop that, probably stop...
  14. I looked up our rates locally today for a...

    I looked up our rates locally today for a customer who wants a quote on an electric boiler over gas. Just for fun I punched in my 95% gas vs my heat pump. The heat pump is pushing 3 times the cost...
  15. Get a TCONT/ACONT 824 control, you can adjust the...

    Get a TCONT/ACONT 824 control, you can adjust the constant fan speed from that control/thermostat.
  16. Replies
    14
    Views
    430

    I looked up the relic on Webcats parts program....

    I looked up the relic on Webcats parts program. Didn't find a C1 but used C0. It gave a bunch of part #s. Compressor, 2 caps and a mounting kit. Our AS distributor has the part in stock so my guess...
  17. Replies
    14
    Views
    430

    That's the indoor unit, need the model # of the...

    That's the indoor unit, need the model # of the heat pump to determine if matching. I would not put a new outdoor unit of any flavor or refrigerant on that unit.
  18. Replies
    2
    Views
    353

    We've sold some of them, just a bypass HEPA...

    We've sold some of them, just a bypass HEPA machine. If you want clean air, get a media air cleaner from Aprilaire, Trion, General, Honeywell etc. You can get a controllable setup to bring fresh air...
  19. From what I saw, there's a 200 CFM gap between...

    From what I saw, there's a 200 CFM gap between the 2 speeds on either side of 1200 CFM. Put your filter in and ask you dealer to take an external static pressure reading of the system. Then he can...
  20. Get the media cleaner put in, so much better than...

    Get the media cleaner put in, so much better than 1" and less restrictive. Your dealer can take a static pressure reading at get down into the 3 ton airflow territory. From what I see, probably going...
  21. Replies
    9
    Views
    365

    I'm pretty sure this combo will do what you want....

    I'm pretty sure this combo will do what you want. Takes buying 3 pieces but I think you can do it with the Vision Pro 8000 TH8321R, the Redlink Equipment Module and a Redlink internet gateway. I've...
  22. Replies
    3
    Views
    1,442

    OK, let me speculate. On the cooling, it could be...

    OK, let me speculate. On the cooling, it could be in the unit ventilator or the building could have a chiller which cools water down to the 40s and then is circulated to the univents like the hot...
  23. Thread: AHR show

    by BaldLoonie
    Replies
    3
    Views
    417

    Been following that. WAAAAAAAH. I love those...

    Been following that. WAAAAAAAH. I love those shows. Flew down to Orlando last Feb. Guess I might have to buzz out to Vegas in 2022.
  24. The modulation will not be based on the needs of...

    The modulation will not be based on the needs of the house, as with the Infinity control, it will modulate based on logic and past cycles. I like the matching stat/control to tell the furnace how...
  25. Replies
    2
    Views
    206

    First, load calc to determine actual heat need...

    First, load calc to determine actual heat need and what the cooling needs are.

    You'll have a hard time cooling the 2nd floor with no returns sucking hot air back to the cooling coil. Sucking off...
  26. Replies
    8
    Views
    280

    Our suburb is blowing up with stuff like that....

    Our suburb is blowing up with stuff like that. http://liveproscenium.com/ is just the latest.

    Most are straight electric heat with A/Cs on the roof. Obviously they went for first cost not...
  27. Replies
    8
    Views
    280

    Do you want cooling? Do you want it cheapest way...

    Do you want cooling? Do you want it cheapest way or most comfort? Natural gas available?
  28. Right

    Right
  29. Rheem & Carrier say minimum run temp is 55 and...

    Rheem & Carrier say minimum run temp is 55 and below, cycle the fan or slow it and put on CCH. I think Carrier has kit to bypass LPS on startup.
  30. Both are made here in Indy still. The electronics...

    Both are made here in Indy still. The electronics division did move to Mexico. They are getting rather similar. We've seen no more issues with ICP brands like Heil than Carrier.

    They gotta be...
  31. Replies
    9
    Views
    311

    Fujitsu and Mitsubishi tend to have the best reps...

    Fujitsu and Mitsubishi tend to have the best reps on here. Friedrich is a good company but don't see much about them these days. We service a management company with a couple of apartments with...
  32. The MN7 is a modulating furnace with variable...

    The MN7 is a modulating furnace with variable speed blower. It is very high end and runs best with the Infinity control. Great in a cold climate as it will vary the fire and blower to provide just...
  33. I couldn't find those exact model #s on Carrier's...

    I couldn't find those exact model #s on Carrier's web site. Only time you need a special stat (and need may not be the right word) is if you have Infinity equipment, especially the furnace....
  34. You can do that. 25kw is a lot of heat. I like to...

    You can do that. 25kw is a lot of heat. I like to see it staged. Like Dean says, hire a technician. 240V is nothing to mess with. As my late colleague rottendog would say, dead is permanent.
  35. Oversized. I have 970 sq ft 30 years old in...

    Oversized. I have 970 sq ft 30 years old in Indiana. 60,000 BTU 95% 2 stage which runs only on low or 33,000 output. Heats fine at -15 out. 2 ton outdoor unit can keep it 70 when 100 out. Only...
  36. Replies
    19
    Views
    576

    I couldn't get the 3.5 ton system to show up with...

    I couldn't get the 3.5 ton system to show up with 3 ton drive & coil.

    I don't know Lennox's registration system as for catching the non rated match. With AS and Rheem, we can register just the...
  37. Winter is -10 around here. We have the hoods...

    Winter is -10 around here.

    We have the hoods but they are supposed to be used only on TXV systems.

    Our inspectors just say can't check A/C due to outdoor temp.
  38. Replies
    19
    Views
    576

    204492617...

    204492617

    Looks like the 1st one is 17/13 so tax credit and possibly utility rebates.

    The 2nd one has a 3.5 ton A/C on a 3 ton coil and a small 3 ton furnace.
  39. What's the thermostat?

    What's the thermostat?
  40. Replies
    9
    Views
    452

    Just your garden variety tank? I tend to lean...

    Just your garden variety tank? I tend to lean Rheem.
  41. Replies
    4
    Views
    377

    Not unusual, especially with high end stuff the...

    Not unusual, especially with high end stuff the distributor or warehouse doesn't move a lot. We got in a 2014 20 ton split earlier this year. Been sitting in Rheem's warehouse 6 years!
  42. Gotta be air noise if it does it both in heating...

    Gotta be air noise if it does it both in heating & cooling. Sounds like undersized ducts. The old furnace likely was a PSC motor and if the static is high, oh well. This new one variable speed motor,...
  43. Call your dealer back and have him see what's up....

    Call your dealer back and have him see what's up. Should have a warranty.
  44. Looks good. Are they still doing 1 side return? I...

    Looks good. Are they still doing 1 side return? I would have put it on a riser box to pull air in the bottom and the side. Right now looks like a 20x25 air cleaner but the top 4" are blocked off by...
  45. Replies
    25
    Views
    688

    I don't see any contractor bothering to do that....

    I don't see any contractor bothering to do that. I tried with our owner & salesman, not interested. Mentioned to our distributor about ordering with them in, not interested.

    Wouldn't be hard in...
  46. As long as the top picture shows the in side of...

    As long as the top picture shows the in side of the coil and not the out, looks good to me.
  47. Seems to me the new way in condos and hotels is...

    Seems to me the new way in condos and hotels is have outdoor air brought in by a special type of A/C /heater package to pressurize the halls to put positive pressure on them to keep your cooling...
  48. Let's move to Tech to Tech, we can say a little...

    Let's move to Tech to Tech, we can say a little more there. Keep working toward 15 posts and reapply for pro membership. We had a big crash a while back which may of caused you to not appear as a...
  49. Replies
    25
    Views
    688

    I think Trane only added pressure switches when...

    I think Trane only added pressure switches when 410 came along.

    I am disappointed with Rheem for making them optional. I'd hazard the guess that very few distributors have them added at the...
  50. Replies
    20
    Views
    569

    18 over 16 would likely have no ROI. But if you...

    18 over 16 would likely have no ROI. But if you have the bucks and aren't looking to pay for high SEER with energy savings. The SLP99 should have the iComfort control, it would be great comfort.