Search:

Type: Posts; User: fridg

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    52
    Views
    2,842

    There is also an Air Assist pump in these that...

    There is also an Air Assist pump in these that becomes energised during harvest
    It pumps air onto the top of the plate between ice & plate to help with the ice to seperate.
  2. Replies
    7
    Views
    1,456

    Veto US only ship locally. Veto Australia...

    Veto US only ship locally.

    Veto Australia have a list price of $471 AU for the backpack ,,, I havenít had a conversation with them to see if this price is reduced for Trade. Other places seem to...
  3. Replies
    7
    Views
    1,456

    VETO Reputable Distributor.

    Hey guys , howís the Evening treating you ?

    I am looking to get some new Veto Bags & Iím Curious to know who is a Reputable Distributor with a Good Price that Ships to Australia ?

    Iím looking...
  4. Thread: CO2 alarm

    by fridg
    Replies
    7
    Views
    1,641

    Innotech can measure & control CO2 ...

    Innotech can measure & control CO2

    https://innotech.com/Solutions/ProjectList.aspx
  5. Replies
    1
    Views
    644

    Nitrogen Pressure Drop Calculator.

    https://www.oceanhvac.com/nitro.php
  6. Replies
    21
    Views
    3,502

    Never knew that , but Australia does not have...

    Never knew that , but Australia does not have much to do with the Sikorsky(in my area anyway).
    I know some of the 1&2 pilot Rotary Wing Aircraft do have remote drop controls.
  7. Replies
    21
    Views
    3,502

    Pilot is responsible for the load he is carrying...

    Pilot is responsible for the load he is carrying , ultimately I think the riggers have made the mistake & the pilot is now wearing it.
  8. Replies
    12
    Views
    2,987

    Manufactures could pay $1 per Schrader Valve ,...

    Manufactures could pay $1 per Schrader Valve , times that by the amount of cabinets they produce each week & there is a huge saving.
  9. Replies
    11
    Views
    3,177

    Check the cost of a new outdoor.

    Check the cost of a new outdoor.
  10. Replies
    9
    Views
    2,314

    Entry level Dtek with CO2 capabilities with...

    Entry level Dtek with CO2 capabilities with sensor change.
  11. Thread: Bad Comp Valves?

    by fridg
    Replies
    7
    Views
    1,340

    55psi is 7íC 80psi is 18íC PT Chart.

    55psi is 7íC
    80psi is 18íC

    PT Chart.
  12. Replies
    7
    Views
    1,068

    The Big Brewers in Oz are ,,, they are the guys...

    The Big Brewers in Oz are ,,, they are the guys that have stipulated.
  13. Replies
    7
    Views
    1,068

    Exactly what we had to do. Some are reopening now...

    Exactly what we had to do. Some are reopening now to 10 patrons at a time. Others have had dry lines for 6+ weeks.

    Bottle shops were deemed essential & were open for trade.
  14. Thread: Carrier AHU Kw ?

    by fridg
    Replies
    3
    Views
    1,124

    Thanks. We did come across that also , we think...

    Thanks. We did come across that also , we think it is actually undersized to begin with.
  15. Replies
    7
    Views
    1,068

    Pubs/Clubs closing the doors as they are not...

    Pubs/Clubs closing the doors as they are not deemed Essential.

    Soft drink & beer will go off before they open & bacteria growing in the lines.
  16. Thread: Carrier AHU Kw ?

    by fridg
    Replies
    3
    Views
    1,124

    Carrier AHU Kw ?

    Any idea of the Capacity of a Carrier 40HW007 AHU ?

    Carrier have no idea.

    40Kw ?
  17. Replies
    7
    Views
    1,068

    Covid-19 Flushing Lines.

    Who else has been Crazy busy , Flushing & Sanitising Beer Lines & PostMix ?

    Now restrictions are being eased its time to go back & Prime all the lines.

    Really puts things into perspective when...
  18. Thread: Bad Comp Valves?

    by fridg
    Replies
    7
    Views
    1,340

    SST is 7íC , should be -7íC SST SCT is 18íC...

    SST is 7íC , should be -7íC SST
    SCT is 18íC should be 45íC SST

    Comp is not pumping correctly.
  19. Replies
    66
    Views
    18,461

    Was a Makita fan , had all 12v gear , needed to...

    Was a Makita fan , had all 12v gear , needed to upgrade some items & was tossing the idea of switching to Milwaukee. Ended up switching to Milwaukee & now I wouldn’t go back to Makita.
  20. Replies
    19
    Views
    3,312

    Most of these jobs are running around servicing...

    Most of these jobs are running around servicing wall splits in the camps. Majority of work is service , of course you will get the occasional breakdown.
  21. Replies
    4
    Views
    823

    Inefficient Temps swings & highly unreliable...

    Inefficient
    Temps swings & highly unreliable especially if used
    In university testing environment.
  22. Replies
    30
    Views
    3,258

    https://www.traveluniverse.com.au/LED-Lenser-P5R-R...

    https://www.traveluniverse.com.au/LED-Lenser-P5R-Rechargeable-LED-Torch/ZL500897?gclid=EAIaIQobChMIuNjbi62S5AIVzYRwCh18xguiEAAYASAAEgJnQfD_BwE
  23. Replies
    18
    Views
    2,575

    Daikin eQuip by Daikin Airconditioning...

    Daikin eQuip by Daikin Airconditioning (Singapore) Pte Ltd
    https://apps.apple.com/au/app/daikin-equip/id473487318
  24. Replies
    22
    Views
    2,472

    No

    No
  25. Replies
    25
    Views
    2,270

    I agree ,,, there may not even be a leak , it...

    I agree ,,, there may not even be a leak , it could be that the stop leak is now slowly blocking the circuit.
  26. Replies
    22
    Views
    2,822

    Depends on your experience / contracts & what...

    Depends on your experience / contracts & what other benefits the employer is offering.

    Large Markets or CStore Markets ?
  27. Replies
    25
    Views
    2,270

    Adding gas every 4-6weeks is a crime Does...

    Adding gas every 4-6weeks is a crime

    Does your electronic leak detector actually work , have you verified it ?
  28. Replies
    8
    Views
    1,202

    Worked on a local soft drink tank a few years...

    Worked on a local soft drink tank a few years back , the water had a nice oily film & this was what was being bottled. :eek2:
  29. Replies
    4
    Views
    929

    There should be a bung plug to pull out of the...

    There should be a bung plug to pull out of the pan to drain it first. I forgot you guys are in Summer over there. I would drain first.
  30. Replies
    4
    Views
    929

    No , but it will take time Remove facia Remove...

    No , but it will take time
    Remove facia
    Remove electrical panel
    Remove fan cowl
    And it should drop down ,, do not tilt it from horizontal as the pan will be full of crap.


    Some...
  31. Replies
    9
    Views
    995

    Equalisation Grilles ? You need to find out if...

    Equalisation Grilles ?

    You need to find out if there is AirFlow out or in ,,,,,this will indicate it connected to a system.

    If 2 are joined together by duct it will be equalisation Grilles so...
  32. Replies
    10
    Views
    4,851

    What Kw is that 7-8?

    What Kw is that 7-8?
  33. Replies
    4
    Views
    1,201

    Loose phase will cause over amp as the correct...

    Loose phase will cause over amp as the correct power is not supplied on each leg. Bit like you trying to run a marathon with one leg ,, sure you can do it but it going to be harder than if you had...
  34. Replies
    15
    Views
    3,066

    Never used my turbo torch since getting this ,,...

    Never used my turbo torch since getting this ,, highly recommended.
    https://www.actrol.com.au/product/tesuco-oxy-turbo-set-200-brazing-m12-7001755

    I use the full size kit for anything over 7/8.
  35. Thread: Inficon Stratus

    by fridg
    Replies
    19
    Views
    4,423

    Following. When released here in OZ Iím told...

    Following.

    When released here in OZ Iím told $1500Au.
  36. Replies
    14
    Views
    3,015

    You need to pick your socks up.

    You need to pick your socks up.
  37. Replies
    6
    Views
    1,365

    You need to have the pans in & no gap where they...

    You need to have the pans in & no gap where they are to be. It will not work otherwise.
  38. Replies
    59
    Views
    9,054

    Local supply house guy (Kev) went on holidays to...

    Local supply house guy (Kev) went on holidays to the Gold Coast with his wife ,,, crossing the road to the beach & had a heart attack ,, he wasn’t as lucky ,,, he never made it home.
  39. Replies
    64
    Views
    9,902

    You can actually buy work pants with a pocket to...

    You can actually buy work pants with a pocket to insert your foam pads into. We wear them in the Emergency Services & you donít even know they are there until you go to kneel & the ground is soft.
    ...
  40. Replies
    155
    Views
    97,255

    Mixing GAZES is fine , how do you find the one...

    Mixing GAZES is fine , how do you find the one otherwise.

    Mixing GASSES on the other hand is a no-no as you no longer have the purity.
  41. Replies
    22
    Views
    3,562

    X2 Get the SH right & go from there.

    X2

    Get the SH right & go from there.
  42. Replies
    22
    Views
    3,562

    Put a door switch on to shut the solenoids & fans...

    Put a door switch on to shut the solenoids & fans down on opening & leave open states.
  43. Replies
    7
    Views
    1,394

    A few minutes to get to -10 ,,, compressor is...

    A few minutes to get to -10 ,,, compressor is loosing effiency.
  44. Replies
    18
    Views
    1,418

    Put ball valves in so you can have multiple...

    Put ball valves in so you can have multiple components ,, just shut the ball valves for the Fault scenario you want to replicate.
  45. Thread: Psychrometer

    by fridg
    Replies
    18
    Views
    2,579

    When you need logging capabilities over a number...

    When you need logging capabilities over a number of days this then is placed onsite.

    https://www.hobodataloggers.com.au/hobo-ux100-temprh-35-data-logger-ux100-003
  46. Thread: Psychrometer

    by fridg
    Replies
    18
    Views
    2,579

    They are good ,, just don’t let it be bounced &...

    They are good ,, just don’t let it be bounced & bumped around. Mine goes in a CD Head Unit Face Plate Container with Foam inside.
  47. Replies
    7
    Views
    2,749

    I was informed that the sensors only last...

    I was informed that the sensors only last 1000hours of use.
    My first sensor went while it was under warranty & because it is a consumable it was not covered. I stated it was under 12months old &...
  48. Thread: Psychrometer

    by fridg
    Replies
    18
    Views
    2,579

    https://www.fieldpiece.com.au/PRH2-Pocket-Psychrom...

    https://www.fieldpiece.com.au/PRH2-Pocket-Psychrometer

    Pretty Accurate. Use it @ Art Galleries to check temp & Rh & is almost bang on the same numbers as what the museum data loggers show.
  49. Replies
    14
    Views
    1,933

    Haha. Plenty of time to come up with one ,,, no...

    Haha. Plenty of time to come up with one ,,, no rush.
  50. Replies
    21
    Views
    3,235

    For some reason it doesnít come up as a...

    For some reason it doesnít come up as a Hyperlink. If you copy & paste it works as pecmsg has stated.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4