Search:

Type: Posts; User: Pascone10

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    5
    Views
    315

    The Honeywell Eagle was introduced a year or two...

    The Honeywell Eagle was introduced a year or two go and is an AX model. The Honeywell Eagle Hawk or Ciper50 is the N4 version.
  2. Replies
    2
    Views
    299

    Thank you for the reply. I’ll look into the...

    Thank you for the reply. I’ll look into the memory for sure. I looked in the security part and I don’t see a passcode. I was wondering if that could be the issue But I can get to the config. I really...
  3. Replies
    2
    Views
    299

    Trane Rover Service Packs

    Hey Guys,

    I tried to upload an MP580 TGP program the other day and the upload failed. This is the first time I have ran into this. I was able get the config from the controller. I am curious if I...
  4. Replies
    4
    Views
    829

    Ciper50 is WEBs only I believe.. There is N4 and...

    Ciper50 is WEBs only I believe.. There is N4 and AX versions of that controller.
  5. Replies
    18
    Views
    1,320

    Thank you for replying. It is nice that you are...

    Thank you for replying. It is nice that you are looking at the forums. Diego did reply. I have not went back to the thermostat to learn more about it. I was not overly excited about how far it stands...
  6. Replies
    18
    Views
    1,320

    Thank you for sharing that document. I...

    Thank you for sharing that document.

    I ordered it the first week they sent out an email announcing it. No links were up on their website yet. Thatís when I had to start searching and found...
  7. Replies
    18
    Views
    1,320

    I ordered one. Itís rebranded from another...

    I ordered one. Itís rebranded from another manufacturer. I tried to get BACnet points info from CC and a SOP but no one returned my email or phone calls.
    Itís sitting on the shelf right now.

    I...
  8. Replies
    18
    Views
    1,320

    EasyIO FW Series uses WiFi. Fully programmable as...

    EasyIO FW Series uses WiFi. Fully programmable as well.
  9. Replies
    9
    Views
    622

    That makes sense. The Spyder tool is a love or...

    That makes sense. The Spyder tool is a love or hate I feel when talking to guys. I personally cut my teeth with it about 5 years ago. I really enjoy it but it sure has some quirks.

    On a separate...
  10. Replies
    9
    Views
    622

    Both are fine. But there is always a learning...

    Both are fine. But there is always a learning curve when switching brands.

    What is the reason that you are considering Honeywell over JCI?
  11. Replies
    19
    Views
    1,440

    I hear you there BB. There are positive and...

    I hear you there BB. There are positive and negatives to both. Unfortunately, most of the time the customer does not know what they are buying until it's too late. Than we get into situations like...
  12. Replies
    19
    Views
    1,440

    Contemporary Controls or KMC has good MSTP to...

    Contemporary Controls or KMC has good MSTP
    to IP Routers.

    Also FYI. If you go the TU route that software expires after a year....
    If there is no BACnet comm and no supervisor I would swap...
  13. Thread: VPN Routers

    by Pascone10
    Replies
    19
    Views
    1,646

    Yes I am just going to play with it to learn and...

    Yes I am just going to play with it to learn and try the features. I will check at what you suggested. I am not sure what you were referring to about importing to the ER. THat sounds interesting. IF...
  14. Thread: VPN Routers

    by Pascone10
    Replies
    19
    Views
    1,646

    Orion- I got this from Ubiquiti- This is to...

    Orion- I got this from Ubiquiti- This is to change how long the certificate is good for. By default its only one year ( i am sure you know all that but here is how they recommended changing it)
    ...
  15. Thread: VPN Routers

    by Pascone10
    Replies
    19
    Views
    1,646

    Hey Guys. So I was able to FINALLY get OpenVPN...

    Hey Guys. So I was able to FINALLY get OpenVPN set up on my ER Lite. I had quite a bit of trouble with it, being a noob.

    I have been putting quite a bit of thought into this stuff lately and...
  16. Thread: VPN Routers

    by Pascone10
    Replies
    19
    Views
    1,646

    klrogers, so you prefer the softkey. Good to...

    klrogers, so you prefer the softkey. Good to know! Thanks
  17. Thread: VPN Routers

    by Pascone10
    Replies
    19
    Views
    1,646

    Thank you Orion for the detailed reply. Have...

    Thank you Orion for the detailed reply.

    Have you set up the ER for as an OpenVPN server?

    I am working still so on brain overload. Ill digest the rest of what you wrote tomorrow. Just curious...
  18. Thread: VPN Routers

    by Pascone10
    Replies
    19
    Views
    1,646

    VPN Routers

    I was wondering what products you are using the securely access remote site via a VPN server such as OpenVPN.

    Is anyone using TosiBox?

    I bought a Ubiquity Edge Router and spent way too much...
  19. Replies
    12
    Views
    2,181

    The UI is very different. But that is just the...

    The UI is very different. But that is just the look. Some things got moved around. Otherwise it's similar to 10.2. Speaking of which, you roll back to 10.2 when using the MS/TP products. 10.3 is...
  20. Replies
    9
    Views
    1,120

    Well said Dave CR! I'm going to use that one! I...

    Well said Dave CR! I'm going to use that one! I am not too much of a fan of the QA apps unless they are exact to what I need. Then they are just OK

    OP- if you are not very familiar with PCT...
  21. Replies
    22
    Views
    1,211

    Great. Good idea. I sent an email to my...

    Great. Good idea. I sent an email to my distributor for a quote. Thank you very much for your help!
  22. Replies
    22
    Views
    1,211

    https://www.musiciansfriend.com/pro-audio/eliminat...

    https://www.musiciansfriend.com/pro-audio/eliminator-lighting-ed-15-4-channel-dmx-lighting-dimmer-pack/l10347000000000?cntry=us&source=3WWMWXGP&gclid=CjwKCAjw3cPYBRB7EiwAsrc-ueQuETGSCi1kDk7tbGKauQRe-M...
  23. Replies
    22
    Views
    1,211

    Awesome. I'll look into this. We are working to...

    Awesome. I'll look into this. We are working to replace the old DMX dimmer. If I can work with that I'll be set. I'll report back!
  24. Replies
    22
    Views
    1,211

    Analog to DMX converter. Sounds interesting....

    Analog to DMX converter. Sounds interesting. Could you post an example?

    Analog I have 0-10vdc or 4-20ma available
  25. Replies
    22
    Views
    1,211

    I was afraid I was going to get a reply like...

    I was afraid I was going to get a reply like this. It's unreal!!!

    This same job I learned that 0-10vdc light dimmers are the opposite of what we use and are sink dimmers. If you ever get involved...
  26. Replies
    22
    Views
    1,211

    Dimming Lighting

    Hey guys. Is anyone getting involved in lighting controls that can help me out? I have 120vac lights that are dimmed from the high voltage side. Is there a rack or module of some sort that will...
  27. Replies
    6
    Views
    1,096

    I use the PID object from easyIOHVAC. Intergral...

    I use the PID object from easyIOHVAC. Intergral time has the following definition in the manual--

    Integral Gain
    Defines the integral gain parameter, in repeats per minute, used by the loop...
  28. Replies
    1
    Views
    666

    Did the computer use workbench software to access...

    Did the computer use workbench software to access the site before of a web browser?

    Did you try reaching out to your controls contractor for support?
  29. Replies
    31
    Views
    1,741

    An oscilloscope will give you an idea of what the...

    An oscilloscope will give you an idea of what the bus is doing as far as voltage.

    A DMM is not much use for troubshooting the issues you are having.
  30. Replies
    31
    Views
    1,741

    So they don't want any controls contractor back...

    So they don't want any controls contractor back in the building or just not the ones you had?

    See its a slippery slope as far as who's fault the comm issues are. Generally when your contracted to...
  31. Replies
    31
    Views
    1,741

    Hello d-griff. I see you have a bcp bacnet...

    Hello d-griff.
    I see you have a bcp bacnet network. I have seen that with other brands but not honeywell Webs JACE.

    We need to make sure you are working on the right network and right bus. The...
  32. Replies
    34
    Views
    5,372

    Glad to see you here Mike. You guys are doing...

    Glad to see you here Mike. You guys are doing good things. Keep it up! I spent last night going through your new training series. Excited for the advanced videos you have been mentioning.

    I...
  33. Replies
    21
    Views
    1,261

    Is the MS 251 the one with the single bar nut?

    Is the MS 251 the one with the single bar nut?
  34. Replies
    6
    Views
    628

    Gotcha. I am familiar with the EOL. Thank you for...

    Gotcha. I am familiar with the EOL. Thank you for the clarification.
  35. Replies
    6
    Views
    628

    Danny, can you elaborate on what you mean by...

    Danny, can you elaborate on what you mean by workplacePro being unlocked now please.
  36. Replies
    5
    Views
    912

    Are you locally connected to the controller with...

    Are you locally connected to the controller with an Ethernet cable? Not remote access that a port could be blocked?
  37. Replies
    33
    Views
    3,783

    Gotcha. VMware so far is much better than what i...

    Gotcha. VMware so far is much better than what i was using to do what you are trying to do. ( I was using Windows XP mode). You need a decent pc and put the VM on it. Mine is very snappy and is way...
  38. Replies
    33
    Views
    3,783

    VMware player is free for non Commercial use. You...

    VMware player is free for non Commercial use. You can give that a try then buy a version if it work. It's only a couple hundred. I recently started using VMware and am very pleased. What your asking...
  39. I think it just shuts down the heat. I'm not sure...

    I think it just shuts down the heat. I'm not sure that it does anything with the cfm. If I get 10 mins tonight I'll pull up a project and see what it does. That would have helped with your OP.
  40. Replies
    11
    Views
    2,547

    New Honeywell Products; EagleHawk

    So from what I hear the the USA release of the EagleHawk in the coming weeks. Has anyone seen or worked with them yet? I had a quick intro at a contractor appreciation day in the fall.

    I am...
  41. Is there a point HW-Avail, or something like...

    Is there a point HW-Avail, or something like that. Im not on my PC with PCT but I thought that point was created with the tool most of the time on VAV boxes. I am sure JCIman would know but thought I...
  42. Replies
    33
    Views
    3,783

    The HP Probook 650 has legacy ports which include...

    The HP Probook 650 has legacy ports which include serial. I ordered a couple of them and they seem to work well.

    My latest PC is a HP Zbook 15. 512SSD and an I7, 16gb ram. I am still working on...
  43. Thread: Trane ZN520

    by Pascone10
    Replies
    5
    Views
    748

    OK to follow up.. Willf650 I do again want to...

    OK to follow up.. Willf650 I do again want to thank you for your help. What I found is the config in the Trane MP580 has an option to select how you want that Generic Output to work ( N/O or N/C)...
  44. Thread: Trane ZN520

    by Pascone10
    Replies
    5
    Views
    748

    I will give that a shot. I really appreciate the...

    I will give that a shot. I really appreciate the reply. I'll let you know how it goes !
  45. Thread: UA STAR??

    by Pascone10
    Replies
    17
    Views
    2,495

    I took Nate maybe 10? years ago.. IMO Nate was...

    I took Nate maybe 10? years ago.. IMO Nate was not challenging at all. Star was more complicated by far.
  46. Thread: Trane ZN520

    by Pascone10
    Replies
    5
    Views
    748

    Has anyone used the proprietary Trane NV's at all?

    Has anyone used the proprietary Trane NV's at all?
  47. Replies
    10
    Views
    1,816

    Cagey, So I did some digging as I remember...

    Cagey, So I did some digging as I remember hearing Greg Wilmer talking about the set command in one of his FX PCT controllers. What he ended up saying was not really related to this N2 so I won't...
  48. Replies
    13
    Views
    2,969

    Bumping an old thread here. Trane told me...

    Bumping an old thread here. Trane told me nviTraneVar1 is used to write to the generic output on the ZN520. I spent hours with Trane Tech support and Node util and could not get that point to close...
  49. Replies
    10
    Views
    1,058

    Oops. That was supposed to say I DONT think it's...

    Oops. That was supposed to say I DONT think it's wise...
  50. Replies
    10
    Views
    1,058

    Thank you for the replies. I'm am not so...

    Thank you for the replies. I'm am not so interested in calibrating their existing sensors as there are a lot of variables obviously that can make what they are reading different then a thermometer...