  1. Replies
    4
    Views
    250

    I would get a BACnet trunk out to the TUX and...

    I would get a BACnet trunk out to the TUX and replace it. Too much of a hassle to get the program out of the APEX unless they still have the workstation and it's functioning. The IBEX line has been...
  2. Replies
    4
    Views
    250

    This is all I have that references a TUX-450....

    This is all I have that references a TUX-450. From what I remember, there is no DDC in the controller memory. All control comes from the APEX.
  3. Replies
    8
    Views
    316

    So simple, yet effective! I'm going to delete...

    So simple, yet effective! I'm going to delete what I did and use that. Thanks!
  4. Replies
    8
    Views
    316

    Thanks! I'll give it a shot

    Thanks! I'll give it a shot
  5. Replies
    8
    Views
    316

    We are using a numeric switch to manipulate the...

    We are using a numeric switch to manipulate the setpoint then the false slot of the switch is set to null so it returns to normal when the timer expires. This is for an Automated Demand Response from...
  6. Replies
    8
    Views
    316

    Analog Value Ramp in Tridium

    I have to do a timed override on a setpoint in N4 and when It gets released, the customer wants it to ramp back to the normal value over a period of time instead of just switching back. Is this...
  7. Replies
    20
    Views
    661

    If it works, I'll put your picture as the home...

    If it works, I'll put your picture as the home page on the Jace!
  8. Replies
    20
    Views
    661

    The customer has a killer WiFi network that they...

    The customer has a killer WiFi network that they will let me use. If I put the Jace on their ethernet and port over the WiFi devices, would that bypass the limitations? Sounds like what Numbawunfela...
  9. Replies
    20
    Views
    661

    Thanks for all the replies! I'll post updates if...

    Thanks for all the replies! I'll post updates if I come up with a solution.
  10. Replies
    20
    Views
    661

    Jace WiFi Device Limit

    Does anyone know how many WiFi devices I can bring into an N4 Jace? I have a site that needs to disable electric baseboard in 115 rooms. They will not allow us to run wires and would like a wireless...
  11. Replies
    2
    Views
    342

    Thanks!

    Thanks!
  12. Replies
    2
    Views
    342

    Jace 8000 SMA Notification

    Anyone know how to get rid of the SMA expiration notification on the login page? TIA
  13. Replies
    1
    Views
    464

    Honeywell Spyder Issue

    I'm running WEBstation-N4 4.6.96.28 and I'm adding Spyders to a Jace that never had them. My Spyder Tool is 7.2.15. I can't see the honeywellSpyderTool module to install it into the Jace under...
  14. Replies
    2
    Views
    295

    Take the .dist file from the backup and change...

    Take the .dist file from the backup and change the extension to .zip then extract it. That should give you all your graphics.
  15. Thread: Bql Query?

    by The Reaper
    Replies
    4
    Views
    385

    Add a slot path like AHU Name to your query.

    Add a slot path like AHU Name to your query.
  16. Replies
    4
    Views
    1,311

    It seems to only happen when it's a station that...

    It seems to only happen when it's a station that I didn't create. I ended up rebuilding it on my PC and the problem went away.
  17. Thread: BQL Query

    by The Reaper
    Replies
    6
    Views
    644

    Sorry Orion for the misspell! I wasn't wearing my...

    Sorry Orion for the misspell! I wasn't wearing my glasses!
  18. Thread: BQL Query

    by The Reaper
    Replies
    6
    Views
    644

    Thanks Qrion! The slotPath was where I went wrong.

    Thanks Qrion! The slotPath was where I went wrong.
  19. Thread: BQL Query

    by The Reaper
    Replies
    6
    Views
    644

    BQL Query

    I have a job where I have 80 vav boxes on 2 different AHU's. They are named VAV1-1 for AHU-1 and VAV2-1 for AHU2 ect...
    I'm fairly new to BQL and I need to grab zone temp and reheat position into a...
  20. Replies
    10
    Views
    946

    Put your email in your profile please. Or just...

    Put your email in your profile please. Or just shoot me an email.
  21. Replies
    4
    Views
    1,311

    Finally got it working. Had to manually run the...

    Finally got it working. Had to manually run the daemon from the console. When I try to transfer a station to my local host so I can run it on my PC, I get this error. Any ideas?

    Transfer failed....
  22. Replies
    4
    Views
    1,311

    Siemens Workbench Platform Daemon

    My Siemens Workbench 4.7 platform daemon is stuck in startup and will not run. When I run the daemon from the start menu it says installed successfully but I cannot transfer a station to the local...
  23. There should be a paste special option. Select...

    There should be a paste special option. Select "keep all links"
  24. You wouldn't happen to have a copy of Rover would...

    You wouldn't happen to have a copy of Rover would you?
  25. Replies
    21
    Views
    2,962

    Could you send it my way as well please? Thank...

    Could you send it my way as well please? Thank You!
  26. What if you make a sample and hold circuit in the...

    What if you make a sample and hold circuit in the NAE and link it to trigger when the NAE reboots? Here is a picture of one I use in the FEC's.
  27. First off, welcome to the forum! In my...

    First off, welcome to the forum! In my experience, there are too many controls techs out there who know computers and technology but lack a good base knowledge of mechanical systems. I think you are...
  28. Replies
    5
    Views
    6,460

    Hi Chris. I can't even begin to tell you how...

    Hi Chris. I can't even begin to tell you how heavy my heart is for you and the kids. Laura was not just a top notch professional, but one of the most warm, caring individuals I have ever had the...
  29. Replies
    7
    Views
    995

    Thanks for all the replies! I did try to install...

    Thanks for all the replies! I did try to install 3.8 and it would not license. I'm going to call my support channel and I'll post results.
  30. Replies
    7
    Views
    995

    The in house guy just wanted to use the...

    The in house guy just wanted to use the supervisor as a tool on his laptop while he goes between different buildings so he won't be running them together. He does have embedded workbench on the WEBS...
  31. Replies
    7
    Views
    995

    He doesn't want to upgrade the AX Jace yet. Would...

    He doesn't want to upgrade the AX Jace yet. Would he need an AX supervisor with a different license or could he just install the AX version on the same machine as the N4 and be covered by his license.
  32. Replies
    7
    Views
    995

    Honeywell WEBS 4.6 Supervisor

    I have a customer that just purchased a supervisor for his N4 Jaces. He has a 3.8 WEBS 600 in one of his buildings with Spyders. He wants to be able to upload/download the Spyders with his...
  33. Replies
    10
    Views
    1,148

    The driver for Tridium is an ASD driver. As far...

    The driver for Tridium is an ASD driver. As far as isolating the AHU, that would depend on what else you have in the field. Are there VAV boxes for the zones or does the AHU just control for a...
  34. Replies
    10
    Views
    1,148

    I don't know about Rockwell's ability to...

    I don't know about Rockwell's ability to integrate but I have successfully integrated to Barber Coleman with a Tridium Jace at least a dozen times. Pretty much every DDC manufacturer can control to...
  35. Replies
    10
    Views
    1,148

    In order to connect to a GCM and the Microzone...

    In order to connect to a GCM and the Microzone controllers you will need a copy of XPSI. Are you trying ti integrate to the BC stuff first and then upgrade or are you just ripping it out? I have...
  36. Here is a paste from the manual: 4.30 0000•7FFF...

    Here is a paste from the manual:
    4.30 0000•7FFF Channel Attributes (SPL Program Attributes) Channels 0000 through 7FFF are reserved for user•defined, RAM•resident SPL program attributes. When you...
  37. The GC-1 manual refers to these custom channels...

    The GC-1 manual refers to these custom channels in section 4-30. I have personally used channels such as 1000 as long as I declare them in the program.
  38. Replies
    7
    Views
    928

    Check your tuning policy on the BO's for the...

    Check your tuning policy on the BO's for the compressor start command. Make sure the Min/Max write times are set to 0. If not, they will randomly start. Don't know if this is exactly your issue but...
  39. Do you have a copy of SoloPro? It sounds like a...

    Do you have a copy of SoloPro? It sounds like a user defined custom SPL channel. I would upload the controller and decompile the program. That will show you if it is used or not.
  40. Replies
    13
    Views
    2,095

    As someone who farts in church A LOT, I agree...

    As someone who farts in church A LOT, I agree wholeheartedly! Hey, they are called pews!
  41. Replies
    13
    Views
    2,095

    Thanks Scott. I think I'll be recommending N4.

    Thanks Scott. I think I'll be recommending N4.
  42. Replies
    13
    Views
    2,095

    Java Web Start

    I have a site with 20 WEBS-600 Jaces and a Supervisor at 3.8.111. The customer can no longer access his system with Firefox. He said his Firefox did an update and after that it stopped working. I...
  43. Replies
    8
    Views
    1,534

    I would just use a MAP1810 gateway. I've used it...

    I would just use a MAP1810 gateway. I've used it many times. I know on the older Simplicity boards you just use a USB to 485 convertor and wire + to B and - to A
  44. It sounds like they are not set up as Network...

    It sounds like they are not set up as Network Inputs in the PCV. In the Jace, instead of writing to Present Value on the numeric writeable, change the attribute to 3113 and see if it writes then.
  45. Replies
    2
    Views
    663

    Thanks for the info!

    Thanks for the info!
  46. Replies
    2
    Views
    663

    Alerton VLC Question

    Been about 12 years since I worked on Alerton and I've been tasked with calibrating all of the space sensors in a school. I have access to all the VLC DDC programs but I can't remember how to apply...
  47. Replies
    18
    Views
    2,314

    They do have some pre-built stuff for VVT but I...

    They do have some pre-built stuff for VVT but I don't care for it. That's just me personally though. This job was done in phases and the Jace went online at the end. I needed to make the system as...
  48. Replies
    18
    Views
    2,314

    I did this exact job with PCV's and PCG's last...

    I did this exact job with PCV's and PCG's last year. Only source of heat is in RTU's. I ended up installing a duct sensor on the inlet of each zone damper that way if the zone needs cooling and the...
  49. Replies
    2
    Views
    575

    Yes.The .caf file is a complete backup of that...

    Yes.The .caf file is a complete backup of that controller.
  50. Replies
    22
    Views
    1,417

    I did alot of the AAM PUP controllers back in the...

    I did alot of the AAM PUP controllers back in the day but haven't touched the Cylon stuff. As far as cascaded control, instead of using 2 PI loops, I use 1 PI that is fed a setpoint by a reset block....