Search:

Type: Posts; User: orion242

Page 1 of 20 1 2 3 4

Search: Search took 0.10 seconds.

  1. Specializing in franken units lol.

    Specializing in franken units lol.
  2. Replies
    39
    Views
    4,010

    With the constant stream of folks having issues...

    With the constant stream of folks having issues with it, they need to cover the support costs lol.
  3. Replies
    192
    Views
    17,873

    Don't need to bother with BACnet if you just want...

    Don't need to bother with BACnet if you just want to poke at a Modbus device. Setup your mapping in the webpage and hit test. Value will show there and you can modify the setup, test, modify, test,...
  4. Replies
    192
    Views
    17,873

    Sounds like there is little need for capture then...

    Sounds like there is little need for capture then imo.
  5. Replies
    192
    Views
    17,873

    Thinking about that more, the test feature in the...

    Thinking about that more, the test feature in the point setup covers 90% of the struggle imo. Guess the only thing I would wonder is how are modbus exception codes exposed? Will the test feature...
  6. Replies
    192
    Views
    17,873

    Nice update Lin. Like the copy buttons, much...

    Nice update Lin.

    Like the copy buttons, much easier to duplicate things.
    Didn't catch the test button in the point setup. Another slick feature.

    Like the BACnet points for the comms fail...
  7. Replies
    192
    Views
    17,873

    Ditto. Been ignoring the error, my modbus test...

    Ditto. Been ignoring the error, my modbus test device was disabled as well. Have to assume it was the modbus config in this case with all the changes. Noticed the daemon was not running on the...
  8. Gateway could be at the top end of the subnet. ...

    Gateway could be at the top end of the subnet. Odd but see it. Shouldn't matter directly connected and on the same subnet.
  9. Could be a non-standard port as well.

    Could be a non-standard port as well.
  10. Replies
    4
    Views
    474

    Those modules should be already signed by Tridium...

    Those modules should be already signed by Tridium if you get them from Vykon 4.8+.
  11. Replies
    1
    Views
    362

    If the vendor doesn't give it to you, could...

    If the vendor doesn't give it to you, could always look for a side channel.

    Power analysis with something like the chipwhisperer should give you some direction. Bonus, same method will work...
  12. Replies
    22
    Views
    739

    Solid advise for software that has been riddled...

    Solid advise for software that has been riddled with constant security issues over the years.
  13. Replies
    10
    Views
    558

    Lol, sounds like jack has changed then.

    Lol, sounds like jack has changed then.
  14. Replies
    3
    Views
    359

    But its an upgrade! lol.

    But its an upgrade! lol.
  15. Replies
    19
    Views
    660

    They must be a member, so can't blame for not...

    They must be a member, so can't blame for not getting too excited. Already extracted a few bucks from them.

    None the less, hopefully it eliminates another garbage truck advertising as an Escalade.
  16. Replies
    33
    Views
    2,451

    You have posted this in about a dozen threads...

    You have posted this in about a dozen threads over the last few days. Give it a break already. Maybe no one has it or they are not willing to share it with someone spamming the forum.
  17. Replies
    25
    Views
    1,029

    https://www.youtube.com/watch?v=6lutNECOZFw&t=34s

    https://www.youtube.com/watch?v=6lutNECOZFw&t=34s
  18. Replies
    19
    Views
    660

    Report back if you get anything from BTL.

    Report back if you get anything from BTL.
  19. Replies
    19
    Views
    660

    If it gave me 5 min of headache and it appears...

    If it gave me 5 min of headache and it appears its not really listed, all I need to tip off BTL and let them return the headache.
  20. Replies
    19
    Views
    660

    Would bring that up with BTL. Seems like a...

    Would bring that up with BTL. Seems like a misuse of their logo to me. Don't see anything in their listed devices that look anything like that guy.
  21. Replies
    192
    Views
    17,873

    Seems like that's a good idea just for the desigo...

    Seems like that's a good idea just for the desigo folks. Could use nothing but and flip the bird to licensing fees.
  22. That should take in account the station timezone....

    That should take in account the station timezone.

    Do you have them set correctly when you open platform - administration? Right below the time should be the station timezone.
  23. Replies
    36
    Views
    11,720

    https://buildingcontrols.honeywell.com/contractor_...

    https://buildingcontrols.honeywell.com/contractor_search

    You will need a license before its even going to launch.
  24. Replies
    192
    Views
    17,873

    Lol, ya there is no limit on the craziness out...

    Lol, ya there is no limit on the craziness out there. Non-IEEE floats can be a treat. At some point, its not the gateway's problem anymore. Long as I know what the registers mean, understand any...
  25. Never used Tridium for this, but I'm betting you...

    Never used Tridium for this, but I'm betting you need it on both since some could fool around with the logs in the Jace potentially. Another reason to just use whatever controller in the field with...
  26. You don't need external loggers. They could be a...

    You don't need external loggers. They could be a bigger hassle to deal with as they would have to meet the handful of FDA requirements around log tampering, auditing, etc. Not to mention if you...
  27. Replies
    192
    Views
    17,873

    Looks like most of common Modbus format foolery...

    Looks like most of common Modbus format foolery is covered in this guy. byte order, signed16, unsigned16, doubles, float, etc. I'm assuming byte order is little / big endian. One can of course run...
  28. Replies
    19
    Views
    768

    Ditto pull a backup and launch it on your laptop...

    Ditto pull a backup and launch it on your laptop to see.
  29. Replies
    192
    Views
    17,873

    Would also think about a user defined multiplier...

    Would also think about a user defined multiplier on all integer datatypes that defaults to 1.

    Tons of vendors are too lazy to implement 32bit IEEE floats and the common work around is...
  30. Replies
    192
    Views
    17,873

    CSV file Modbus mapping setup would be a plus. ...

    CSV file Modbus mapping setup would be a plus. Would rather script large setups than hours of clicking to setup a large install. Is the Modbus master module import format documented? If not, can...
  31. Replies
    192
    Views
    17,873

    More feedback on the point setup in the web UI. ...

    More feedback on the point setup in the web UI.

    If you hit edit on a newly created point, would be nice to have enabled already checked. If your editing, more often than not it’s to enable it.
    ...
  32. Should be able to use a standard controller...

    Should be able to use a standard controller reporting to Tridium in many cases. Haven't used Tridium in this app yet, but I assuming the esig license is really just adding another layer of security...
  33. Replies
    192
    Views
    17,873

    Bit would be what I expect. Agree. Can't...

    Bit would be what I expect.



    Agree. Can't imagine filling out all the state texts if there are more states than a 16bit register could contain.



    Agree with that as well. If your not...
  34. Replies
    19
    Views
    768

    https://www.jacksoncontrol.com/technical-tips/2019...

    https://www.jacksoncontrol.com/technical-tips/2019/5/31/tech-tip-niagara-web-launcher-is-available-for-download

    AX 3.8u4 and higher from the looks of it.
  35. Thread: N4.10

    by orion242
    Replies
    3
    Views
    268

    Using it on a small site now. Hasn't blown up...

    Using it on a small site now. Hasn't blown up yet...
  36. Replies
    19
    Views
    768

    Pretty sure its part of the web.jar.

    Pretty sure its part of the web.jar.
  37. Replies
    192
    Views
    17,873

    Second look, correct. Your reading a coil, aka...

    Second look, correct.

    Your reading a coil, aka 1x modbus function code. I would expect in datatype is bit or coil, signed makes no sense.

    In the case I asked about, its U16. Aka single 16bit...
  38. Replies
    12
    Views
    735

    Kennel with this setup? Betting they have planed...

    Kennel with this setup? Betting they have planed on flushing large amounts of junk without issue if they want 2" flush valves. Drains prob 2x this valve or more with special attention paid into the...
  39. Replies
    192
    Views
    17,873

    Nice. Think I see what Max is talking about. ...

    Nice.

    Think I see what Max is talking about. Datatype is confusing in this case as its not signed16. Unsigned16 or U16 would be better than blank imo.
  40. Replies
    192
    Views
    17,873

    Might be better to show bitx/coil rather than...

    Might be better to show bitx/coil rather than blank.

    Do you have a way to handled the case where its a holding reg that really is 16 separate bits but the OEM cannot be bothered with supporting...
  41. Replies
    6
    Views
    433

    Or the program ID. Kinda pissing in the wind...

    Or the program ID. Kinda pissing in the wind without some details and even then your hoping for a controls archivist to search their microfiche index.
  42. Thread: VPN Routers

    by orion242
    Replies
    178
    Views
    12,140

    Lol Would think if you can get the kind of PR...

    Lol

    Would think if you can get the kind of PR Fazio did over the Wally world fiasco, you'll be trying to scrub your employment history at that outfit everywhere. Not that it had anything to do...
  43. Thread: VPN Routers

    by orion242
    Replies
    178
    Views
    12,140

    Sniffing? Hell its probably backing up your...

    Sniffing? Hell its probably backing up your openvpn keys for you as well. Its a two'fer!

    Whois privacy on the domain, nice touch. That thing is bound to raise some eyebrows just about anywhere...
  44. Replies
    192
    Views
    17,873

    Had to think on it for a min. Your right, with...

    Had to think on it for a min.

    Your right, with that checked the router will not expose its device object. So it would have to be unchecked to get the name.
  45. Replies
    192
    Views
    17,873

    Think you need to check client mode off under...

    Think you need to check client mode off under application.
  46. Thread: VPN Routers

    by orion242
    Replies
    178
    Views
    12,140

    Shoot Amazon doesn't even have this in stock. ...

    Shoot Amazon doesn't even have this in stock.



    goodcloud.zyx? That just sent shivers down my spine.
  47. Can't suck them out of the J8?

    Can't suck them out of the J8?
  48. Replies
    192
    Views
    17,873

    Just played with this for a bit and got it...

    Just played with this for a bit and got it working. Just kicked the ties a bit, but looks fairly workable modbus 2 bacnet gateway.

    Guess the first thing that jumps at me is settings to control...
  49. Replies
    9
    Views
    600

    Should do the same with the switch between 4 & 1....

    Should do the same with the switch between 4 & 1. Then all the switching is done on the hot side.

    Either way should get'r'done.
  50. Replies
    9
    Views
    600

    Roger, so its a single pressure switch with dual...

    Roger, so its a single pressure switch with dual contacts.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4