  1. I found it humorous that Dallas County’s list of...

    I found it humorous that Dallas County’s list of essential businesses includes liquor stores.
  2. Replies
    12
    Views
    455

    Post a pic of the ring. Maybe I can get some...

    Post a pic of the ring. Maybe I can get some brownie points also!
  3. Replies
    5
    Views
    323

    Look at manufacturer’s specs and see what the...

    Look at manufacturer’s specs and see what the throw would cover. Instead of a wall mount, maybe a suspended four way cassette head will give you a better coverage area.
  4. Instead of draining into downspout, run drain...

    Instead of draining into downspout, run drain down exterior of downspout.
  5. Thread: Tare Weight

    by rglasgow
    Replies
    9
    Views
    932

    Rundawg sounds So much more knowledgable when he...

    Rundawg sounds So much more knowledgable when he says it!
  6. Thread: Tare Weight

    by rglasgow
    Replies
    9
    Views
    932

    From my experience, the R410 tank is about 9...

    From my experience, the R410 tank is about 9 pounds.
  7. Thread: Tare Weight

    by rglasgow
    Replies
    9
    Views
    932

    I dont believe there is a tare weight on tank....

    I dont believe there is a tare weight on tank. But I have been wrong before.
  8. Thread: Tare Weight

    by rglasgow
    Replies
    9
    Views
    932

    Weigh tank before and after servicing unit. Dont...

    Weigh tank before and after servicing unit. Dont need a tare weight for the tank.
  9. Replies
    11
    Views
    551

    Is it my old eyes or is the return coming into...

    Is it my old eyes or is the return coming into the back of the furnace?
  10. Replies
    35
    Views
    1,840

    As previously stated, if he doesn’t know DC...

    As previously stated, if he doesn’t know DC voltage between communication terminals 1 & 2, he is chasing his tail. And yes I have seen the same symptoms other than the changing superheat settings.
  11. Replies
    10
    Views
    428

    Call a contractor. There are ways to install a...

    Call a contractor. There are ways to install a sealed boot to existing duct whether flex or metal. Takes a little ingenuity.
  12. Those are cased coils where the case is...

    Those are cased coils where the case is ductboard. They are designed to not need a supply plenum. Do NOT flow air properly. Someone needs to measure system static pressure.
  13. Maybe you can post a picture of your set-up. Some...

    Maybe you can post a picture of your set-up. Some air handlers DO have a factory installed condensate overflow sensor. If you are in a tower and a common drain runs from top to bottom of building, a...
  14. Replies
    35
    Views
    1,840

    Ask your tech if he knows what dc voltage should...

    Ask your tech if he knows what dc voltage should be between terminal 1 & 2. If he doesn’t know what it should be he will spend a lot of time chasing his tail.
  15. I was assuming you were talking about an...

    I was assuming you were talking about an emergency pan. New construction in Austin does not require float switch if secondary pan is piped. Retrofits need emergency pan piped AND a float switch.
  16. If the drain pan is piped to empty overflow...

    If the drain pan is piped to empty overflow condensate, they were not required to install float switch in Austin. You could probably get a contractor to install a float switch if you desire.
  17. You need to be discussing with your agent. As...

    You need to be discussing with your agent. As Pecmsg said “get your hvac contractor to look at the furnace”. Just because he has a license does NOT mean very much.
  18. Replies
    244
    Views
    13,495

    Took bad stats back to distributor today. They...

    Took bad stats back to distributor today. They had heard about a recall from Honetwell but did not have any details.
  19. Replies
    244
    Views
    13,495

    The two I replaced were both 1926 date code

    The two I replaced were both 1926 date code
  20. Replies
    244
    Views
    13,495

    I am on jobsite now. Two furnaces not...

    I am on jobsite now. Two furnaces not functioning. 27 volts R to C. 12 volts W to C. Jumper thermostat and both furnaces fire up.
  21. Replies
    3
    Views
    620

    Kinda what I thought but hoping someone smarter...

    Kinda what I thought but hoping someone smarter than me would approve. Also makeup air under door would be near floor exhaust.
  22. Replies
    3
    Views
    620

    Bath exhaust location

    I think I know the answer to my question but thought I would see what everyone else thinks. I need to add a bath exhaust to an old house. Attic access is sketchy until GC cuts access hole. There is a...
  23. Replies
    45
    Views
    2,003

    For proof ask for the installation manual. Most...

    For proof ask for the installation manual. Most manuals will illustrate a transition.
  24. Possibly a condensate pump?

    Possibly a condensate pump?
  25. What part of Texas?

    What part of Texas?
  26. Replies
    40
    Views
    1,512

    You stated it ran for 3 hours and no condensation?

    You stated it ran for 3 hours and no condensation?
  27. Replies
    24
    Views
    1,203

    Whether new or used, if proper voltage to board...

    Whether new or used, if proper voltage to board but no voltage to motor, board is bad. I have installed new boards that were bad. Makes you pause and recheck everything.
  28. Replies
    22
    Views
    1,224

    For TESP in a gas upflow furnace, you need two...

    For TESP in a gas upflow furnace, you need two measurements. Static pressure between filter and blower then static pressure before ac coil. Your return pressure is 0.31 and ASSUME coil pressure of...
  29. The best way for contractor to verify duct sizes...

    The best way for contractor to verify duct sizes is to check static pressure. If he cant prove it is within manufacturer’s specs, then he needs to correct it.
  30. Since you are in Texas, go to TDLR website and...

    Since you are in Texas, go to TDLR website and file a complaint. A computer generated Manual J is a code requirement. The AC contractor may listen to licensing board.
  31. Replies
    16
    Views
    1,997

    I think it’s a good idea myself. Will be doing...

    I think it’s a good idea myself. Will be doing that later today.
  32. Replies
    4
    Views
    330

    The two filters are better than just one. The big...

    The two filters are better than just one. The big question is what happened to your flue pipe?
  33. Replies
    57
    Views
    7,973

    Actually in Texas you have a recourse. Go to the...

    Actually in Texas you have a recourse. Go to the TDLR website and file a complaint. If more consumers would follow up with TDLR, maybe we could get rid of some of the hacks.
  34. Replies
    14
    Views
    2,475

    Kangaroogod, your setup looks s lot better. Dont...

    Kangaroogod, your setup looks s lot better. Dont see a setup like that around here.
    To tomjo, the best way to assure proper airflow is to measure. Did installer leave any start up reports? Or just...
  35. Replies
    14
    Views
    2,475

    Are you saying that there is only a 16" hole for...

    Are you saying that there is only a 16" hole for the return?
  36. Replies
    14
    Views
    2,475

    If he left installation instructions with you, I...

    If he left installation instructions with you, I would verify that only one side inlet is adequate on a 110,000 btu furnace. Would like to see a picture of the complete furnace.
  37. Replies
    25
    Views
    2,815

    ARS- Always Recruiting Salesmen

    ARS- Always Recruiting Salesmen
  38. Replies
    8
    Views
    1,050

    I think the heat strip compartment is right next...

    I think the heat strip compartment is right next to that pan. I could also be wrong.
  39. Thread: refrigerant

    by rglasgow
    Replies
    26
    Views
    1,571

    Or maybe you have a new customer

    Or maybe you have a new customer
  40. Thread: refrigerant

    by rglasgow
    Replies
    26
    Views
    1,571

    If they come out once a year for "tune-ups", I...

    If they come out once a year for "tune-ups", I would think they have had a chance to check the charge. The "aux" light will come on when you crank the heat up or if the heat pump can't maintain...
  41. Replies
    7
    Views
    4,093

    Our supplier also sells 250' rolls of wire.

    Our supplier also sells 250' rolls of wire.
  42. I would use square feet for cross sectional area....

    I would use square feet for cross sectional area. The other units are good.
  43. Yes that works now. The other flaw is the...

    Yes that works now. The other flaw is the calculated cross sectional area rounds to whole numbers, no fractions.
  44. Replies
    23
    Views
    1,274

    Is this the first winter it has run? May be...

    Is this the first winter it has run? May be slightly overcharged. Technician would need to verify. As Kdean suggested, low indoor airflow. This two items would cause high pressure lockout.
  45. Looked at your app for a few minutes. Looks...

    Looked at your app for a few minutes. Looks handy. My only problem was I could not figure out how to change to Imperial measurements. If I have to measure in metric units...it wont happen. Too old to...
  46. Replies
    18
    Views
    2,416

    Just seems like 5 ton is way oversized for house...

    Just seems like 5 ton is way oversized for house with spray foam. I guess no one measured static pressure with old system in place. The high static pressures will shorten the life of your expensive...
  47. Replies
    18
    Views
    2,416

    You should talk with your installing contractor....

    You should talk with your installing contractor. The State of Texas requires that a Manual J load calculation be done on all retrofits. Unless San Antonio has stricter codes, the 2012 Uniform...
  48. Replies
    18
    Views
    2,416

    Since it is a month old, have you discussed the...

    Since it is a month old, have you discussed the issues with the installer?
  49. Replies
    12
    Views
    1,553

    The Lennox reversing valve does not energize in...

    The Lennox reversing valve does not energize in heat. Rheem and Ruud are the only heat pumps to use "B" that I know of. Maybe I misunderstood what you wrote.
  50. I dont know that there is a max airflow option....

    I dont know that there is a max airflow option. There is an option for heat kit size. It would be in Comfortnet or Installer menus.