Search:

Type: Posts; User: koolkahuna

Page 1 of 13 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    22
    Views
    2,143

    After the refrigeration system is repaired and...

    After the refrigeration system is repaired and functioning properly, check that the condensate drain has a P-trap that is properly holding water to prevent infiltration into the box. It needs to be...
  2. Replies
    37
    Views
    2,789

    "The solution to pollution is dilution" - Jim...

    "The solution to pollution is dilution" - Jim Ignatowski
  3. Replies
    37
    Views
    2,789

    "Experience is what you get thirty minutes after...

    "Experience is what you get thirty minutes after you need it" - Merv Kozey
  4. Replies
    37
    Views
    2,789

    The Egyptians actually used evaporative cooling...

    The Egyptians actually used evaporative cooling with R718 refrigerant (dihydrogen monoxide) thousands of years before Willis Carrier came up with electric air conditioning. Americans may have better...
  5. Replies
    37
    Views
    2,789

    Bbq don't lie!

    Bbq don't lie!
  6. Replies
    7
    Views
    947

    I stand corrected. I remember reading that it...

    I stand corrected. I remember reading that it shouldn't be spiralled and it shouldn't cross over itself. This manual says both are okay. Now I wonder if I read that or was told that. 🤔
  7. Replies
    27
    Views
    3,020

    Defrost Termination Fan Delay switch not working...

    Defrost Termination Fan Delay switch not working properly. Coil has to freeze the moisture onto the fins before the evap fan(s) start(s). This is to eliminate blowoff of moisture into the box which...
  8. Replies
    7
    Views
    947

    Instructions for a field built self regulating...

    Instructions for a field built self regulating heat tape state to not wrap the heat tape around the drainline. Lay it underneath the pipe or INSIDE the drainline. Power it on defrost cycle only or on...
  9. Replies
    37
    Views
    2,789

    Youtube has lots of videos how to service these...

    Youtube has lots of videos how to service these systems. R290 can be purchased at supplier for cheap in small canisters. Do NOT use torch until system charge is released to atmosphere and lines have...
  10. Replies
    16
    Views
    1,802

    You need to have enough net positive pressure at...

    You need to have enough net positive pressure at the pump inlet to make it work properly. Your described symptoms tell me you don't...

    An expansion tank is used in a chilled water system to...
  11. Replies
    16
    Views
    1,802

    Is the expansion tank waterlogged? You will need...

    Is the expansion tank waterlogged? You will need enough system pressure to keep the pumps from cavitating and have "pressured water" to the pump intake.
    Try adding air or nitrogen if you have it,...
  12. Replies
    3
    Views
    1,415

    Naval jelly, spray paint to match original oem...

    Naval jelly, spray paint to match original oem color.
  13. Replies
    2
    Views
    1,060

    ICE Tech support 1-844-423-9378

    ICE Tech support
    1-844-423-9378
  14. Replies
    14
    Views
    2,342

    Have dielectric unions been installed?

    Have dielectric unions been installed?
  15. Replies
    29
    Views
    3,370

    Jim, you will want to drain ALL the oil as it is...

    Jim, you will want to drain ALL the oil as it is POE which is very hygroscopic. This means that the oil absorbs moisture and will not release it. This is why Mineral and Alkylbenzene oil is supplied...
  16. Replies
    17
    Views
    2,216

    We use them a lot. More for swaging though....

    We use them a lot. More for swaging though. Flares do work but look sketchy at first. You need a good drill with a high rotational speed and it helps to preheat the copper if you have a weaker drill....
  17. Replies
    2
    Views
    851

    We've been looking into getting one. One of my...

    We've been looking into getting one. One of my techs has a small domestic sized unit and it cleans 2 square ft coils very well. Better than high pressure nitro. Looking st a $4K portable unit from...
  18. Replies
    21
    Views
    3,540

    I just re-read post #13 for the reasons you were...

    I just re-read post #13 for the reasons you were concerned about.
    So if you want to use conduit and pull it around a long sweep this is one of many solutions that a competent trained professional...
  19. Replies
    21
    Views
    3,540

    What reasons would necessitate the need to...

    What reasons would necessitate the need to replace the lineset in the future?
  20. Replies
    24
    Views
    2,778

    9 years life on a Veto bag is way too short! I...

    9 years life on a Veto bag is way too short! I guess the new ones made in China don't come close to the early quality units made in USA.
    Veto chose profit over quality by making that decision. They...
  21. Replies
    24
    Views
    2,778

    Invest in a Veto LC. Mine is now over 10 years...

    Invest in a Veto LC. Mine is now over 10 years old and going strong. I used to be able to bench over 300lbs and rip 4" phone books in half but wouldn't go bigger than an LC unless it was a backpack....
  22. Replies
    117
    Views
    10,465

    [QUOTE=BBeerme;24920741]POE is compatible with...

    [QUOTE=BBeerme;24920741]POE is compatible with all refrigerants.

    All new refrigerants but not compatible with R12.
  23. Replies
    12
    Views
    2,483

    Way to go! Winner winner chicken dinner!

    Way to go!
    Winner winner chicken dinner!
  24. Replies
    12
    Views
    2,483

    Collapsing 45 gallon drums is non hvac 😂

    Collapsing 45 gallon drums is non hvac 😂
  25. Replies
    31
    Views
    4,163

    Beautiful install! Push It does have a point...

    Beautiful install!
    Push It does have a point though.
    The galvanized clamps will corrode through copper due to the dissimilar metals. Probably not very quickly but galvanic action will cause...
  26. Replies
    44
    Views
    5,768

    So if you were to choose between Appion and...

    So if you were to choose between Appion and Bluevac, which one and why? Anything better than these?
  27. Replies
    40
    Views
    12,041

    Leak Lock has its' place and so does Nylog.

    Leak Lock has its' place and so does Nylog.
  28. Replies
    41
    Views
    4,387

    Yup. BTDT. It waves at you saying "Over here!" If...

    Yup. BTDT. It waves at you saying "Over here!" If you tape plastic or gloves over suspect components or connections that are not obviously inflated from escaping gas, cut a small slit in the plastic...
  29. Replies
    4
    Views
    1,437

    Even a $5000 Imager will show the same as your...

    Even a $5000 Imager will show the same as your cheaper unit IF there is NO temperature difference. As there is no refrigerant evaporating off of the top level of the liquid in the receiver like it...
  30. Replies
    40
    Views
    12,041

    [QUOTE=technocratic;24649651]I can't believe I...

    [QUOTE=technocratic;24649651]I can't believe I just used the word bling. Does it show I have highschool aged kids?

    Appion IS the new BLING.
    That is some groovy, far out, techno swag right there 😆
  31. Replies
    40
    Views
    12,041

    Thanks itsiceman, I agree it's possible in the...

    Thanks itsiceman,
    I agree it's possible in the right environment if all the planets align but the ice would still sublimate (maybe take longer) and you would have bigger problems with that much...
  32. Replies
    40
    Views
    12,041

    My son is being taught in trade school that if a...

    My son is being taught in trade school that if a vacuum is pulled too fast by having an oversized pump, the low pressure will freeze the moisture before it can pull it out. Anyone else ever hear...
  33. Replies
    4
    Views
    1,437

    Sure will. Just pour hot water over the receiver...

    Sure will. Just pour hot water over the receiver and the liquid level will show up considerably cooler than the vapour as the metal will not heat up with liquid touching it and will heat up a great...
  34. Thread: Flashlights

    by koolkahuna
    Replies
    80
    Views
    11,243

    Flood-It rechargeable with rare earth magnetic...

    Flood-It rechargeable with rare earth magnetic feet. Expensive but perfect. Also have the cheap mastercraft two pack of weaponized led penlights that take triple A's for 16bux. 8 bux a light, bright...
  35. Replies
    1,859
    Views
    103,599

    Good post! 100% truth right there.

    Good post! 100% truth right there.
  36. Replies
    1,859
    Views
    103,599

    Brians' fan club!

    [QUOTE=Brian GC;21548001]Hey Tool, I know how you like to hear about my bike rides. Well, last Thursday I rode a hard pace around Lake Tahoe. 72.2 mi, 4,037' of elevation gain, 3 hours 57 min, 18mph...
  37. Replies
    31
    Views
    15,683

    Most definitely! I posted info a year after the...

    Most definitely! I posted info a year after the OP for that same reason. All I'm saying is that it would be decent for him to get back to us and post an update.

    597261
  38. Replies
    31
    Views
    15,683

    We'll probably never know. He posted it 4 years...

    We'll probably never know. He posted it 4 years ago and only has 9 posts in total. :cool:
  39. Thread: Chain Saws

    by koolkahuna
    Replies
    23
    Views
    3,028

    [QUOTE=BBeerme;20807691]I got to do that with a...

    [QUOTE=BBeerme;20807691]I got to do that with a machine gun once.


    EDIT:
    Oh wait, I read that wrong. It was only a four inch pine.

    Cool!
    I had a job with forestry collecting new growth tree...
  40. Thread: Chain Saws

    by koolkahuna
    Replies
    23
    Views
    3,028

    [QUOTE=CleterD;20806851]I like the old saws even...

    [QUOTE=CleterD;20806851]I like the old saws even though they are heavy. My main saw is a Homelite Super XL that I bought used in the 70's. Recently picked this jem up, another heavy saw from the...
  41. Thread: Chain Saws

    by koolkahuna
    Replies
    23
    Views
    3,028

    Sorry to hear about Husqvarna not backing up...

    Sorry to hear about Husqvarna not backing up their product. Never heard of that from husky before.
    I used to be a professional buckerman and I have a husky 181 32 years old and a 288 14 years old I...
  42. Replies
    74
    Views
    13,897

    You're on the fast track to learn a lot here....

    You're on the fast track to learn a lot here. Grab the handles, get the required information and hold on! It's gonna be a ride!
    Seriously, follow instructions and we will save your bacon brother.
  43. Replies
    74
    Views
    13,897

    I think now we are getting somewhere. You have...

    I think now we are getting somewhere. You have now posted some info we can use to help you. It sounds like you are indeed a refrig mechanic. We quite often get people who try to scam info out of us...
  44. Replies
    74
    Views
    13,897

    If he was this bad why work for him in the first...

    If he was this bad why work for him in the first place? Maybe he's feeling like a few of us on this site. That you may be the problem. We are happy to help other mechanics but you don't know enough...
  45. Replies
    74
    Views
    13,897

    Why would there be 25psi suction pressure at the...

    Why would there be 25psi suction pressure at the condenser? :(
  46. Replies
    21
    Views
    13,283

    Also used by duct cleaners. They call it a...

    Also used by duct cleaners. They call it a skipper. The air pulls the hose in and the backward facing air jets disturb the dust while the large vac truck pulls the dirt out.

    I can't see the pics...
  47. Replies
    12
    Views
    10,257

    Now that write their is funny!

    Now that write their is funny!
  48. Replies
    74
    Views
    13,897

    Does the compressor pass the three second test?...

    Does the compressor pass the three second test? Put your hand on the top of the hermetic can for 3 seconds. If you can't cause it's too hot then somerhing isn't right. Is the condenser dirty or water...
  49. Replies
    74
    Views
    13,897

    Brian, are you an HVAC/R mechanic? Your 20 year...

    Brian, are you an HVAC/R mechanic? Your 20 year old company you speak of, what trade(s) does it encompass?
    My thinking is that you should get a qualified tech to repair this, perhaps one of your own...
  50. Replies
    1,071
    Views
    316,717

    You definitely have a good temperament to handle...

    You definitely have a good temperament to handle a problem child.
    Good on ya!
Results 1 to 50 of 613