Search:

Type: Posts; User: Snapperhead

Page 1 of 20 1 2 3 4

Search: Search took 0.11 seconds.

  1. Terro Ant Killer Get the little "bottle" of...

    Terro Ant Killer

    Get the little "bottle" of liquid and put droplets all along their trail ( dont buy those clear traps )

    Its like syrup

    They carry the poison back to the farm and they all...
  2. I wish ...

    I wish ...
  3. Im not sure if they live in Bamboo ? But for...

    Im not sure if they live in Bamboo ? But for sure they live under Ivy leaves and low growing plant leaves

    Have you ever called one of those fogging companies ?
  4. Replies
    16
    Views
    331

    Well dam , says right on the blade Cast Iron ,...

    Well dam , says right on the blade Cast Iron , thats cool
  5. Replies
    16
    Views
    331

    Lets see ... once i used a sawzall with about 3...

    Lets see ... once i used a sawzall with about 3 milwaukee blades , that shit took forever , I've used a torch one time ( dont do it , lots of popping like popcorn) I've used the rigid chain break ,...
  6. Replies
    17
    Views
    469

    They finally got smart Hell yeah that last...

    They finally got smart

    Hell yeah that last much longer that way
  7. Replies
    9
    Views
    410

    Your techs only pull out torches during slow...

    Your techs only pull out torches during slow seasons ?

    What kind of company is this again ??
  8. My Name Is Mud Your name reminded me of this...

    My Name Is Mud

    Your name reminded me of this video .... skip to about the 7:40 minute mark

    https://www.youtube.com/watch?v=BsrMqnNxy1o
  9. I have a few gas stations that are ofcourse .......

    I have a few gas stations that are ofcourse .... Indian owned , and they always tell their Indian friends about me.

    One day I get a call " My friend Raja told me you do good work , please come"
    ...
  10. Replies
    6
    Views
    257

    If the chef base works good without puddling of...

    If the chef base works good without puddling of water inside , then you are good to go with just leveling the grill alone

    If the chef base puddles .... pffft man Im not sure what to tell you
    ...
  11. Replies
    6
    Views
    257

    those are for setting the points gap on...

    those are for setting the points gap on distributors ....
  12. Replies
    6
    Views
    257

    I would put something under the grill legs ...

    I would put something under the grill legs

    Swapping out chef base wheels for legs would be my last idea ... those are a MF to move even with wheels !

    Anything except wood

    Old plastic...
  13. Replies
    9
    Views
    410

    I didnt think an employer was allowed to ask DOB...

    I didnt think an employer was allowed to ask DOB ... for like several years now ...

    You dont replace compressors or evaps ?

    So all you do is show up with a clip board and sell people units ?
  14. Replies
    19
    Views
    563

    Is this pump down ? I always turn up the stat...

    Is this pump down ?

    I always turn up the stat so it pumps down , turns off , then I torch the receiver to see how much liquid it has

    If its over half full I will let it slide , but you want...
  15. Replies
    27
    Views
    634

    Ok so its been a few days and the only thing I...

    Ok so its been a few days and the only thing I did was remove the fancy covering

    No more sweating since ....
  16. Replies
    25
    Views
    765

    I've seen invoices from others ... and remember...

    I've seen invoices from others ... and remember seeing a "rooftop access charge" of 50 dollars one time , to replace Air Filters
  17. Replies
    37
    Views
    746

    Pffft ... F that , I would quit , seriously

    Pffft ... F that , I would quit , seriously
  18. You've been a member for almost 10 years and have...

    You've been a member for almost 10 years and have no idea what a TXV is ....
  19. Those amps lean toward a weak Capacitor also ... ...

    Those amps lean toward a weak Capacitor also ...

    For that price I hope he uses AMRAD USA made capacitor ...
  20. Replies
    37
    Views
    746

    Those holes could possibly be covered with a...

    Those holes could possibly be covered with a copper patch and brazed .... working word here is Possibly

    You take bare copper wire , like 14ga , wrap around the pipe nice and snug leaving no gaps ...
  21. Replies
    61
    Views
    1,394

    just need to add a little more freezy juice if...

    just need to add a little more freezy juice if using a larger drier
  22. Replies
    50
    Views
    1,355

    Hot swapping out Hi Press / Low Press Sensors...

    Hot swapping out Hi Press / Low Press Sensors while under 10 psi , maybe even a Shrader ... no need to pump down

    Removing the Piston Nut , then pulling out the Piston .... will Definitely allow...
  23. Replies
    61
    Views
    1,394

    That looks like a 052 maybe ? Its the same one I...

    That looks like a 052 maybe ? Its the same one I carry

    How in the world did that much crap get in there .....

    Did you use some sorta flush ?

    It looks like you flushed the system and couldnt...
  24. Replies
    16
    Views
    493

    So ..... you go turn on the unit ... how long...

    So ..... you go turn on the unit ... how long does it run until it trips the breaker ?
  25. Replies
    16
    Views
    493

    Well , something usually causes a compressor to...

    Well , something usually causes a compressor to fail

    Alot of times you install a new compressor ... and then have to begin diagnosing why the old one failed

    Your diagnosing skills are about...
  26. My 1st experience with a latching relay had me...

    My 1st experience with a latching relay had me confused for a couple of Days and many ...many hours

    I had no idea it was supposed to stay closed on its own , or stay off , depending on which power...
  27. Replies
    6
    Views
    275

    even the manufacturer knows its garbage lol ...

    even the manufacturer knows its garbage lol

    they probly have their fingers crossed it makes the 12 months !

    I will admit though , some of those units last Several years , and some only 2 years...
  28. Replies
    61
    Views
    1,394

    and that would explain how both high and low side...

    and that would explain how both high and low side gauges went to 0

    If the line entering the filter was brazed shut , his high side port suddenly becomes a low side port .... because it was on the...
  29. Replies
    61
    Views
    1,394

    :worthless:

    :worthless:
  30. Replies
    61
    Views
    1,394

    that makes zero sense ... Well , unless the...

    that makes zero sense ...

    Well , unless the drier was clogged up , and seeing that 30 degree split across the drier certainly points to a clog
  31. Ive always wondered if those bypass type setups...

    Ive always wondered if those bypass type setups actually perform well in both positions ....
  32. Well , to even get eyes on that coil you would...

    Well , to even get eyes on that coil you would need a pair of tin snips and alot of cussing

    What is the temp difference now that its been serviced ?
  33. Did they remove the obstruction in the Evaporator...

    Did they remove the obstruction in the Evaporator Coil ?

    If you replace your filters regularly the coil should be clean , especially with that nice filter rack you have there

    I usually see...
  34. Replies
    27
    Views
    634

    honestly I didnt pay that close attention because...

    honestly I didnt pay that close attention because I didnt know both lines got cold until you mentioned the valve was in the OD unit
  35. Replies
    27
    Views
    634

    Mmmmm Hmmmm good question

    Mmmmm Hmmmm good question
  36. Replies
    27
    Views
    634

    You can see the linesets running up left and...

    You can see the linesets running up left and right wall of porch against brick
  37. Replies
    27
    Views
    634

    I take that back ... looks like 2 cables

    I take that back ... looks like 2 cables
  38. Replies
    27
    Views
    634

    I took this pics couple weeks ago ... Looks like...

    I took this pics couple weeks ago ... Looks like 4 cables , 2 are hard to see
  39. Replies
    27
    Views
    634

    I was actually hired run the 220 , but didnt have...

    I was actually hired run the 220 , but didnt have anything to do with the runs to the heads , so I have no idea what wires you want me to switch ( if I find the problem you describe) I've never ran...
  40. Replies
    27
    Views
    634

    the whole insulation was covered in droplets

    the whole insulation was covered in droplets
  41. Replies
    27
    Views
    634

    Its keeping the house nice and cold .... I...

    Its keeping the house nice and cold ....

    I didnt spend much time there and just assumed it would need thicker insulation and left

    I guess I could search for my minisplit adapter and throw on...
  42. Replies
    27
    Views
    634

    On a side note ... I hear a little condensate...

    On a side note ... I hear a little condensate pump running once in while in each unit

    Why on earth would they design it that way ??

    Thats just a accident waiting to ruin the wood floors after...
  43. Replies
    61
    Views
    1,394

    That must be a tiny ass filter Is it one of...

    That must be a tiny ass filter

    Is it one of those copper ones ?
  44. Replies
    27
    Views
    634

    Yea he squirted a ton of silicone in the brick...

    Yea he squirted a ton of silicone in the brick wall penetration

    I told HO to run the units all night with covers off to see if still sweats

    I assume the insulation came on the lineset ?

    Ok...
  45. Replies
    27
    Views
    634

    Mitsubishi lineset sweating in bedroom

    New install by a guy about a month ago , and he cant come to check out the install issue because of a personal problem , so Im asked to look

    When the cover was on .... it was dripping pretty bad...
  46. Replies
    61
    Views
    1,394

    I've never seen a high side drop to zero .... or...

    I've never seen a high side drop to zero .... or even anywhere close to it

    Are you sure you have your red hose on the high side of the system ?

    Something isnt piped right ....
  47. For units with Low charge like reach in coolers ,...

    For units with Low charge like reach in coolers , I have a blue gauge with a 1 inch stub , and a red gauge with a 1 inch stub

    When I remove the red gauge I cant hardly hear anything ... its like...
  48. Replies
    5
    Views
    296

    134 works much better ....

    134 works much better ....
  49. Replies
    35
    Views
    1,017

    I think NPT was the Worst idea ever You have...

    I think NPT was the Worst idea ever

    You have to crank down on the fittings until you are red in the face ... and Hope it seals

    Ive used pipe dope and could never get water pipes to seal...
  50. Replies
    35
    Views
    1,017

    I dont think Nylog was meant to act as a seal...

    I dont think Nylog was meant to act as a seal .... its super slippery and allows you to get more of a turn on a flare nut

    On vehicles we used it on o-rings that constantly turn back n fourth, you...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4