  1. Replies
    13
    Views
    738

    A good air filter should have no effect on the...

    A good air filter should have no effect on the ducts size. The ULtra-Aire 98H connected to the a/c supply could increase the air passing through the supply ducts to the home. The ideal UA install...
  2. Replies
    12
    Views
    3,095

    Cool mist humidifiers require a good air filter...

    Cool mist humidifiers require a good air filter down stream to remove the solids left in the air after evaporation of liquid water. We are talking high merv filters +11. Steam humidifiers leave the...
  3. Fix the motor and operate with merv 7 filter....

    Fix the motor and operate with merv 7 filter. Measure the results. End the discussion.
    ECM motors are easier to adjust the air flow???

    Good tech will get to the bottom of this!
    Keep us posted....
  4. My mistake on missing "not", knowing the actual...

    My mistake on missing "not", knowing the actual temp/%RH in and out of the a/c would tell us is the air is high or low.
    Many comments are intended to sell filters.
    Find a knowledgeable tech get...
  5. OK? Keep in mind, more restriction, less air is...

    OK?
    Keep in mind, more restriction, less air is moved. Remove all restriction and most blowers will overload while moving a lot of air.
    How come you did give us some measurements (temp/%RH)...
  6. I also agree that restricting air flow decreases...

    I also agree that restricting air flow decreases the load on a squirrel cage blower. Also the first move should be to lower the air flow by using taps provided for adjusting the blower speed.
    Keep...
  7. Is there any moisture on the windows after a cold...

    Is there any moisture on the windows after a cold evening? IN cold green grass climates, the limitation is excess moisture on the windows. I suspect your %RH meter in not calibrated properly. Buy a...
  8. I like simple, you need fresh air on/off when...

    I like simple, you need fresh air on/off when occupied and %RH for the dehumidifier. If the home is occupied most of the time, leaving the fresh air on is OK. If you have a routine occupancy, a...
  9. Depending on the size of the crawlspace. If less...

    Depending on the size of the crawlspace. If less than 1500 sq.ft., a supply from the main whole house may handle the space. A separate dehumidifier makes it simpler. Where are a/c air handlers...
  10. My experience is the that the stuffy air and high...

    My experience is the that the stuffy air and high %RH is a 3 mild seasons of the problem. With cold outside air and winter wind, most home get enough fresh air. If anything they have so much dry...
  11. Replies
    6
    Views
    225

    Slowing the fan speed slow cooling rate improves...

    Slowing the fan speed slow cooling rate improves moisture removal. Setup which includes fan speed adjustment to get ideal moisture removal is basic.
    Some installers do not have a clue.
    In the end...
  12. At the end of the cooling cycle, the cooling coil...

    At the end of the cooling cycle, the cooling coil is loaded with moisture. If heat is called for within 1 hour, expect any moisture left on the cooling coil to rapidly to evaporate and pass on the...
  13. Just to make sure that you understand a bubble...

    Just to make sure that you understand a bubble plastic pool insulation that will float on top of the water in the crawlspace will contain the moisture under the plastic that will grow mold and will...
  14. Good question. Each lb. of moisture removed is...

    Good question.
    Each lb. of moisture removed is 1,050 btus of condensing energy. Plust the electricity converted to heat, 580 watts X 3.4 btus = 5,129 btus per hour, +-.
    Close enough?
    Keep in mind...
  15. Yes, the heat from the moisture removal process...

    Yes, the heat from the moisture removal process is added to the home. First off, a well setup a/c should be able to maintain <50%RH during peak cooling loads. If not, the a/c air flow can be adjusted...
  16. A crawlspace that floods is the toughest problem....

    A crawlspace that floods is the toughest problem. I suggest a bubble pack plastic like on a pool. The plastic would float on top of the water. Fasten the plastic to the wall with a strip of plastic....
  17. [QUOTE=PBJ918;25806392]I am located in Tulsa, OK....

    [QUOTE=PBJ918;25806392]I am located in Tulsa, OK. I have an 1100 sqft 1920 craftsman house that I totally gutted in 2012 and made into a very tight, efficient house. All exterior walls, roof deck and...
  18. There is a lot of "Just live with it going on"....

    There is a lot of "Just live with it going on".
    Fresh air is most benefical during the three mild seasons of the year. No wind or stack effect to make fresh air pass through the home removing...
  19. Which house first? Is the larger new home spray...

    Which house first?
    Is the larger new home spray foam also?
    Most experts suggest a filtered fresh air change in 3-5 hours when the home is occupied. Homes have exhaust devices like a clothes...
  20. Replies
    10
    Views
    324

    No need for UV unless your fresh air has a...

    No need for UV unless your fresh air has a pollutant that needs to be controlled by UV.
    With adequate fresh air change to purge indoor pollutants and renew oxygen, filtering spores/pollen/dust is...
  21. Replies
    10
    Views
    324

    Top indoor air quality in a home starts with a...

    Top indoor air quality in a home starts with a fresh air change in 4-5 hours to purge indoor pollutants and renew oxygen at a minimum when occupied. When the outdoor dew point is 50-55^F and the...
  22. Typically a 6" fresh air duct is routed from...

    Typically a 6" fresh air duct is routed from outside to the inlet of the dehumidifier and joined with a return duct from the open part of the home. A 2,500 sq.ft. home needs about 80-100 cfm of...
  23. Good question. Maybe the difference in running...

    Good question. Maybe the difference in running hours and dehu coils may be colder. A/cs have plenty of failures also.
    We will keep on trying to improve.
    Large coils have thicker copper tubing?...
  24. Sorry about missing your original post. Keep us...

    Sorry about missing your original post.
    Keep us posted on any additional question and how the solution works out.
    Regards Teddy Bear
  25. 20 years ago we had

    20 years ago we had <2% failure rate without any special treating or coatings.
    We are currently struggling to get that low with the best of coatings and details. The failure rate has declined...
  26. Replies
    6
    Views
    404

    Fresh air should not be limited to equipment...

    Fresh air should not be limited to equipment operation. Fresh air is needed when the home is occupied to purge indoor pollutants and renew oxygen. Needed for the health of the occupants!

    An air...
  27. Thread: Make up air

    by teddy bear
    Replies
    4
    Views
    218

    Monster hoods are 650 cfm when measured. Regular...

    Monster hoods are 650 cfm when measured. Regular hood more like 100 cfm on high. Ratings are higher but seldom deliver more than 50%.
    Seldom do homes need more than 200 cfm of exhaust. There are...
  28. Replies
    19
    Views
    691

    Lets get back to the problem. Mold inside the...

    Lets get back to the problem. Mold inside the ducts or on the outside? My concern is that you do get mold in the new ducts like the old ones. What climate is this home located in? Cold climate...
  29. Probably a freeze-up of coil as the unit died. Or...

    Probably a freeze-up of coil as the unit died. Or could have been an strong dip in outdoor dew point?
    Regards Teddy Bear
  30. Looken good! Keep us posted. Regards Teddy Bear

    Looken good!
    Keep us posted.
    Regards Teddy Bear
  31. All have had fun with cooling coil refrigerant...

    All have had fun with cooling coil refrigerant leaks. All Therma-Stor coils are epoxy coated and baked. This has dramatically reduced the leaks, but still have occasional leak. Probably chemicals...
  32. Sorry, I missed that. Dew point is different...

    Sorry, I missed that. Dew point is different than temp/%RH. What is the temp/%RH on a/c supply? I will figure the dew point.
    Another point, Fan mode should be "auto" mode. No fan during off...
  33. The Quest dehumidifiers are high efficiency...

    The Quest dehumidifiers are high efficiency dehumidifier made in the USA. They remove 6-9 lbs. per KWH plus provide significant free reheat like 12,000 buts per KWH while removing the moisture. ...
  34. Musst be a winter climate? Fresh air change is a...

    Musst be a winter climate?
    Fresh air change is a must, a fresh air change in 4-5 hours minimal when occupied to purge indoor pollutants and renew oxygen. A valid point on using mechanical fresh air...
  35. Replies
    6
    Views
    404

    Are you saying that because your home is cold, it...

    Are you saying that because your home is cold, it is over-ventilated? The ideal fresh air change rate when a home is occupied is ranges from a fresh air change is 3-5 hours to purge indoor...
  36. Replies
    14
    Views
    2,261

    Any organized fresh air ventilation? Most suggest...

    Any organized fresh air ventilation? Most suggest a fresh air change in 4-5 hours when the home is occupied with normal materials in the home. Without fresh air change, the home will vary with VOC...
  37. Replies
    7
    Views
    272

    Most home have excess summer moisture retained in...

    Most home have excess summer moisture retained in their homes. Start by operating an exhaust fan when the moisture shows on the cold glass. It takes a couple weeks of 24/7 exhaust ventilation to...
  38. Start first by checking the temp/%RH on the...

    Start first by checking the temp/%RH on the return or room air and the supply air to the space. If want a 75^F, <45%RH, a 52^F dew point, the a/c supply must have moisture removal that is equal to...
  39. Go simple a/c and add a small whole house...

    Go simple a/c and add a small whole house dehumidifier with the fresh air option. I assume you live in a green grass climate and are building a quality, air tight home. During calm weather and...
  40. Install is important. If you want 60-70cfm of...

    Install is important. If you want 60-70cfm of fresh air, a 6" insulated duct from the fresh air inlet grill with a screen to the dehumidifier. The small whole house units have an 8" duct inlet. A...
  41. Replies
    19
    Views
    3,755

    SCrapes from construction is the same material...

    SCrapes from construction is the same material the home is made up. I am not in favor of dirty ducts but maintaining a fresh air change is critical to maintain a healthy home purged of common...
  42. Replies
    10
    Views
    3,253

    VS a/c is slightly better that conventional a/c...

    VS a/c is slightly better that conventional a/c or heat pumps. But the most sophisticated VS a/c are unable to maintain <50%RH with a +40% sensible cooling load. During rain and evenings a small...
  43. Replies
    12
    Views
    375

    You are confusing circulation and ventilation. ...

    You are confusing circulation and ventilation. If you air handler blowers are VS, set "on" low speed 100% of the time for both.
    Needing to change filters more often is good, cleaner air and less...
  44. Replies
    14
    Views
    440

    I would include a small whole house dehumidifier,...

    I would include a small whole house dehumidifier, like an Ultra-Aire 70H, in the a/c ducting to avoid moisture problems in the earth ducts. Heat loss/gain is not the problem. Keeping them +50%RH is...
  45. Replies
    14
    Views
    440

    Avoid in ground ducts because of mold growth...

    Avoid in ground ducts because of mold growth because the duct surface cool. Best kept in conditioned space.
    Keep us posted.
    Regards Teddy Bear
  46. Replies
    13
    Views
    738

    All a/cs dehumidify. The higher SEERs have...

    All a/cs dehumidify. The higher SEERs have larger cooling coils for better sensible cooling efficiency. Unfortunately, The coils being larger, require more moisture to load them and start dripping...
  47. The Santa Fe may be more dehumidifier than you...

    The Santa Fe may be more dehumidifier than you need. Tell us about what you are trying to do and in what part of God's Green Earth you are in>
    Regards Teddy Bear
  48. Replies
    13
    Views
    738

    Glad to hear you still kicking. Lower SEER will...

    Glad to hear you still kicking. Lower SEER will do more dehumidification and be easier to setup. Sizing, consider over-sized a/c requires more supplemental dehumidification. Manual J sizing is mid...
  49. Replies
    4
    Views
    451

    Are "VOCs" high when the home is unoccupied?...

    Are "VOCs" high when the home is unoccupied?
    Some of the new monitors are "broad specterm" may include CO2.
    A properly ventilation home should be <1,500 with <4 occupants.
    What type of fresh air...
  50. Replies
    1
    Views
    763

    How about start with temperature and %RH in space...

    How about start with temperature and %RH in space in the air coming from your a/c? All you have told us it that you have a serious mold problem and have had the a/c company out and slowed the a/c...