Search:

Type: Posts; User: UmmScott

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    6
    Views
    516

    What kinda hinges and latch does the door have? ...

    What kinda hinges and latch does the door have?

    Pic or hinge #s?

    Sent from my SM-G975U using Tapatalk
  2. Replies
    15
    Views
    789

    Update. Big thanks to itsiceman and everyone....

    Update.

    Big thanks to itsiceman and everyone.
    Iceman, followed your advice. I didnt tighten the tool very firmly onto the access port. Just enough to where it will seal.

    Pulled shrader out no...
  3. Replies
    15
    Views
    789

    Im gonna try this out. And thanks to...

    Im gonna try this out.


    And thanks to everyone for the replies! Much appreciated

    Sent from my SM-G975U using Tapatalk
  4. Replies
    15
    Views
    789

    Appion valve core tool

    Hopefully im using this wrong and its my fault but...

    Im really not thrilled with these 2 bew core removal tools. They wont grab the shrader at all.

    Is there a better core removal tool or am i...
  5. Replies
    37
    Views
    1,125

    Run a 1/4" liquid line up in there... Get rid of...

    Run a 1/4" liquid line up in there...
    Get rid of cap tube

    Put in correct size expansion valve with FZP/JZP powerhead...

    Problem goes away forever. [emoji106][emoji106][emoji16][emoji16]
    ...
  6. Replies
    16
    Views
    554

    Ive had them do the same thing that hes dealing...

    Ive had them do the same thing that hes dealing with...
    Very short on time and cycles off too quick.

    Sent from my SM-G975U using Tapatalk
  7. Replies
    16
    Views
    554

    Dont use universal stats on these.. Buy the...

    Dont use universal stats on these..
    Buy the randell OE control.

    Sent from my SM-G975U using Tapatalk
  8. Replies
    16
    Views
    554

    Its partially a shitty design. Their idea of...

    Its partially a shitty design.
    Their idea of separate cold rail and box control is great. But...

    Its severely offset by them using generally a low temp condensing unit, too small of condenser...
  9. Replies
    16
    Views
    554

    If it is..those cap tubes like to plug on the...

    If it is..those cap tubes like to plug on the inside.
    Makes the coil get too cold and itll cycle off too soon.

    Just put a TXV in and no more problems [emoji106][emoji106]

    Sent from my SM-G975U...
  10. Replies
    16
    Views
    554

    You dont need a service manual! These are easy....

    You dont need a service manual! These are easy. Just not designed the best.

    Is the inside a cap tube or TXV?

    Sent from my SM-G975U using Tapatalk
  11. Replies
    9
    Views
    478

    Hate to break it to ya man... A 12 horsepower...

    Hate to break it to ya man...

    A 12 horsepower is gonna make a bunch of noise.
    I highly doubt an oil separator would do anything. Maybe a discharge muffler would but probably not much

    Sent from...
  12. Replies
    14
    Views
    643

    I would confirm that you're not flooding back at...

    I would confirm that you're not flooding back at all and not experiencing a flooded start.

    Does this unit have a crankcase heater? If so does it work?

    If it were a flooded start tho, then it...
  13. Replies
    14
    Views
    643

    When it ran were the pressures ok? Sounds like...

    When it ran were the pressures ok?

    Sounds like you'll have to dig a little deeper into it. If you have high suction pressure or even normal suction pressure then you should have Plenty of oil...
  14. Thread: Hoshi KM1601

    by UmmScott
    Replies
    57
    Views
    1,537

    Yup.. was told straight by them. Actually go...

    Yup.. was told straight by them.

    Actually go ahead and try it. Set the float all the way at the bottom. You WILL be back in a week when it freezes up.
    Start with the float midway and adjust from...
  15. Thread: Hoshi KM1601

    by UmmScott
    Replies
    57
    Views
    1,537

    Yes they are different. They are crimped almost...

    Yes they are different. They are crimped almost together inbetween the tubing that runs in the middle

    Sent from my SM-G975U using Tapatalk
  16. Thread: Hoshi KM1601

    by UmmScott
    Replies
    57
    Views
    1,537

    @Snapperhead Is this the new design evap plate?...

    @Snapperhead
    Is this the new design evap plate? Its not straight down but the plate has little dimples and indents going down each row for the cubes??

    If so... you gotta set the float switch...
  17. Replies
    22
    Views
    1,362

    Honestly... I would go the TXV route. Those...

    Honestly...
    I would go the TXV route. Those asian units typically have larger condenser coils (oddly enough) and i wouldnt hesitate throwing in an expansion valve.

    Stand up reachins i would try...
  18. Replies
    22
    Views
    1,362

    Good luck man. You'll never get that system...

    Good luck man.
    You'll never get that system cleaned up and make the repetitive plugged tube issue go away.

    Also, by the time you spend in flushing the evap, replacing the cap tube, draining and...
  19. Replies
    10
    Views
    584

    Whats the model of the scrolls man? Sent from...

    Whats the model of the scrolls man?

    Sent from my SM-G975U using Tapatalk
  20. Replies
    33
    Views
    1,359

    Good. Now, another thing with these machines with...

    Good. Now, another thing with these machines with a float. If the water pressure is high, that float wont be able to close even if u put a new one on.

    So if the float is leaking by, replace it and...
  21. Replies
    33
    Views
    1,359

    Im going to give you some shit now... If you...

    Im going to give you some shit now...

    If you can work on a hoshi then you can work on an ICE series ice o matic. This is a very very easy issue. Just do some thinking and visual inspections,...
  22. Just replace the temp control. Pull it out,...

    Just replace the temp control. Pull it out, making note of how its installed, and look on the body of the control for any sort of part or model number.

    Look it up online, order it, and replace.
    ...
  23. Replies
    18
    Views
    709

    Plus... C420 isnt even a model # unless this...

    Plus... C420 isnt even a model # unless this thing is ancient history

    Sent from my SM-G975U using Tapatalk
  24. Replies
    18
    Views
    709

    Why dont you do some testing and find out? ...

    Why dont you do some testing and find out?



    Sent from my SM-G975U using Tapatalk
  25. Replies
    5
    Views
    433

    A. When in doubt, pick the smaller size. Itll...

    A. When in doubt, pick the smaller size. Itll throttle better and you wont have hunting from too big of a valve.

    B.. remember refrigerant choice matters in picking cartridge size. Sporlan has a...
  26. Replies
    1
    Views
    636

    Call a tech to come out and diagnose it for you ...

    Call a tech to come out and diagnose it for you

    Sent from my SM-G975U using Tapatalk
  27. Replies
    9
    Views
    574

    Atosa...also aurora brand... Easiest prep...

    Atosa...also aurora brand...

    Easiest prep equipment i have worked on so far. Hands down. Once its empty, evap coil and fans are cake to get to.
    Unlike true. Lol

    Sent from my SM-G975U using...
  28. Replies
    12
    Views
    609

    Model number? How old is the machine? If the...

    Model number? How old is the machine?

    If the nickel plating is good and feels smooth, dry the evap plate and very very carefully look it over entirely look for hard calcium deposits anywhere....
  29. Replies
    12
    Views
    609

    Thats your problem. 2 mins is a pretty long...

    Thats your problem. 2 mins is a pretty long harvest.

    Is the evap plate clean?

    Sent from my SM-G975U using Tapatalk
  30. Replies
    12
    Views
    609

    How long is harvest? Sent from my SM-G975U...

    How long is harvest?

    Sent from my SM-G975U using Tapatalk
  31. Replies
    11
    Views
    496

    It might be normal then. Might have to get some...

    It might be normal then. Might have to get some more information on how that program mode works

    Sent from my SM-G975U using Tapatalk
  32. Replies
    11
    Views
    496

    No not those. The actual display. Does it say...

    No not those.
    The actual display.
    Does it say "making ice" full bin, off, etc?

    Sent from my SM-G975U using Tapatalk
  33. Replies
    20
    Views
    1,098

    It must be a software thing... I have had that...

    It must be a software thing...

    I have had that issue too where my pics upload sideways

    Sent from my SM-G975U using Tapatalk
  34. Replies
    11
    Views
    496

    If the light was on, then the pump was being...

    If the light was on, then the pump was being commanded on and was operating correctly.

    What does the display say during this time?

    Sent from my SM-G975U using Tapatalk
  35. Replies
    11
    Views
    496

    Id set my meter up on the pins for the water pump...

    Id set my meter up on the pins for the water pump and check voltage.
    Obviously there will be voltage since the pump runs.

    But then, i would start tapping on the relays on the control board and...
  36. Replies
    8
    Views
    657

    No not in that case. I wouldnt undersize. Only...

    No not in that case. I wouldnt undersize.

    Only thing i would do is increase size due to long line set runs. Thats what i normally encounter anyhow

    Sent from my SM-G975U using Tapatalk
  37. Replies
    6
    Views
    745

    Cool. You could even attempt to mimic the old...

    Cool.

    You could even attempt to mimic the old control somehow with the new one.

    Like if the mechanical controls bulb was strapped to the cold plate, then I would start by setting the cut in...
  38. Thread: -20 f freezer

    by UmmScott
    Replies
    3
    Views
    544

    I would think a 10F td is still ideal. Sent...

    I would think a 10F td is still ideal.

    Sent from my SM-G975U using Tapatalk
  39. Thread: -20 f freezer

    by UmmScott
    Replies
    3
    Views
    544

    Double check that the walk in panels are intended...

    Double check that the walk in panels are intended for use with -20F as well.
    Alot of boxes that aren't intended for that temp have issues with moisture on the outsides especially on the door/frame....
  40. Replies
    6
    Views
    745

    Honestly, get rancos etc-111000 temp control and...

    Honestly, get rancos etc-111000 temp control and mount it on the back wall on the outside of the cabinet. Fish the sensor inside and set the control accordingly. That should work pretty decent for...
  41. Replies
    6
    Views
    745

    First off.. What kinda system is it? Is it a...

    First off..
    What kinda system is it? Is it a simple cold plate that gets cold or is it a finned coil with an evap fan for airflow?

    Sent from my SM-G975U using Tapatalk
  42. Replies
    42
    Views
    3,656

    They already are partnered with Perlick for their...

    They already are partnered with Perlick for their parts department.

    Sent from my SM-G975U using Tapatalk
  43. A while back we installed 3 brand new scotsman...

    A while back we installed 3 brand new scotsman 22inch 400Lb machines at a local college. The odd thing was they were all 208/230V machines even tho they were only small 400Lb capacity units.

    All...
  44. Replies
    5
    Views
    700

    Floating suction typically applies to parallel...

    Floating suction typically applies to parallel systems using more than 1 compressor.

    Floating suction means to slowly raise the suction pressure of the whole system to a point as long as the...
  45. Very important! Make sure they do Not run at...

    Very important!

    Make sure they do Not run at the same time. The only time they should run at the same time is when the heat pump is in AC mode during defrost

    Sent from my SM-G975U using Tapatalk
  46. Thread: Freezer Drain

    by UmmScott
    Replies
    25
    Views
    1,333

    The heat tape doesnt put out enough BTus to...

    The heat tape doesnt put out enough BTus to matter. Plus its insulated so the heat should be retained into the drain line, not released into the freezer space

    Sent from my SM-G975U using Tapatalk
  47. Thread: Freezer Drain

    by UmmScott
    Replies
    25
    Views
    1,333

    I like the idea of running the heat tape on the...

    I like the idea of running the heat tape on the inside of PVC drains

    Sent from my SM-G975U using Tapatalk
  48. Thread: Freezer Drain

    by UmmScott
    Replies
    25
    Views
    1,333

    I would for sure get rid of whatever is cycling...

    I would for sure get rid of whatever is cycling it on and off and wire it to be on 24/7.

    Freezer drains SUCK to redo. One of the worst jobs in my opinion right behind door frame heaters. So if...
  49. Thread: Freezer Drain

    by UmmScott
    Replies
    25
    Views
    1,333

    Generally i see them on all the time. Only on in...

    Generally i see them on all the time. Only on in defrost might be not enough heat and cause trouble especially on long drain lines

    Sent from my SM-G975U using Tapatalk
  50. Thread: unbeleivable

    by UmmScott
    Replies
    8
    Views
    743

    Your post is hard to understand but the last few...

    Your post is hard to understand but the last few sentences made it all make sense.

    Wow thats interesting for sure

    Sent from my SM-G975U using Tapatalk
Results 1 to 50 of 1000