Search:

Type: Posts; User: splus

Page 1 of 13 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    9
    Views
    682

    NEW INSTALL? as in a month or a year old...

    NEW INSTALL? as in a month or a year old regardless any customer of mine would have had me install a brand new unit and i would agree with that
  2. I have a few lp models installed and i have one...

    I have a few lp models installed and i have one that seems to bleed a faint amount of gas near the valve the customer cant smell it but it i noticed it while cleaning the spark arrester on the bottom...
  3. Replies
    21
    Views
    1,776

    Removed just under 1lb of charge and the temp dt...

    Removed just under 1lb of charge and the temp dt was 17deg across the coil which lowered the subcooling to 5 all is good here
  4. Replies
    21
    Views
    1,776

    going tommorow if it stops raining

    going tommorow if it stops raining
  5. Replies
    21
    Views
    1,776

    going back tomorrow with my other digital gauges...

    going back tomorrow with my other digital gauges the liquid line was definitely above 62 degrees it was warm to the touch for sure
  6. Replies
    21
    Views
    1,776

    I'm going to reclaim some of the charge and see...

    I'm going to reclaim some of the charge and see how it acts hopefully the superheat won't change much at all
  7. Replies
    21
    Views
    1,776

    8-10 it's calling for. A return air is all sealed...

    8-10 it's calling for. A return air is all sealed up it's not bringing in a daycare anywhere I can only get a 12 degree temp drop
  8. Replies
    21
    Views
    1,776

    30 degrees subcooling

    New install 2 ton air hander in attic everything new r410,system was evac down to 175 microns its a lennox 13acx and cba25 air handler with txv have not confirmed bulb placement,i have never seen...
  9. Replies
    5
    Views
    592

    The new unit has a 16x11 supply plenum i am...

    The new unit has a 16x11 supply plenum i am adapting to 20x17 its a 3 ton system i could make the supply side plenum around 1-2 inches bigger than the supply side just wondering what this will do to...
  10. Replies
    5
    Views
    592

    Rheem R1 series air handler

    Rheem R1 series air handler
  11. Replies
    5
    Views
    592

    Air handler supply side opening

    any reason why a 4 ton rheem air handler would have a 11"x21" supply side opening and all the allied equipment is in the 20"x20" supply side opening?i i need to change one that has the bigger plenum...
  12. Replies
    11
    Views
    960

    I have repaired or replaced my share of these the...

    I have repaired or replaced my share of these the last one was for a leak from a pvc elbow i called tech support and two days later the ups showes up with a big bos and in it was a entire repair...
  13. Replies
    17
    Views
    944

    10-4

    10-4
  14. Replies
    17
    Views
    944

    You betcha

    You betcha
  15. Replies
    17
    Views
    944

    The existing wire was 10/2 Romex not UF rated...

    The existing wire was 10/2 Romex not UF rated connected to a Romex connector on the back of the disconnect box
  16. Replies
    17
    Views
    944

    It was a basement installationI just didn't like...

    It was a basement installationI just didn't like the way it was installed and made another hole to the right of the line set I'm in the disconnect wire in there
  17. Replies
    17
    Views
    944

    28"

    28"
  18. Replies
    17
    Views
    944

    No it was not it was ran into the bottom hole of...

    No it was not it was ran into the bottom hole of the disconnect the disconnect was mounted right on top of the hole for the line set
  19. Replies
    17
    Views
    944

    romex wire

    romex wire
  20. Replies
    17
    Views
    944

    220LINE BEING SHARED WITH THE LINESET HOLE

    I just saw this on a ac changeout i did the 220 line to the disconnect was in the line set hole and connected to the back of the disconnect box which was mounted right above the hole.I did not leave...
  21. Replies
    20
    Views
    1,331

    would be a lennox 13acx condensing unit

    would be a lennox 13acx condensing unit
  22. Replies
    20
    Views
    1,331

    1/4 OD LIQUID LINE

    1.5 ton cooling only the line set cant be changed (condo unit) 35ft total of 5/8od suction and 1/4od liquid line.can this be done and will it make a difference if its a txv or orfice metering device?
  23. Replies
    3
    Views
    548

    The sensors i have are 10k ohm at 77degreesi cant...

    The sensors i have are 10k ohm at 77degreesi cant find the rating on the defective one all it does is sense temp in the indirect tank
  24. Replies
    3
    Views
    548

    BOILER NTC DOMESTIC WATER SENSOR

    I have a triangle tube pe110 which is showing a open domestic hot water sensor that controls the indirect tank,i have other sensors for tanks from different companys and the all look the same.can i...
  25. Replies
    4
    Views
    1,023

    I will dig a little deeper on the next one i...

    I will dig a little deeper on the next one i see,just seems odd to have the same issue on two different furnaces
  26. Replies
    4
    Views
    1,023

    LENNOX 94W83 CONTROL BOARD ISSUES

    I had two of these boards that send 10-15volts ac to the gas valve terminals when the furnace is powered.one was sending 40 volts every 3rd cycle and took that out also.all power and grounding to...
  27. Replies
    2
    Views
    672

    DOA UNIT LEAKING AT COMPRESSOR TERMINALS

    3-ton straight cool system with a copeland compressor upon startup all is well so i go to the coil to tend to some loose ends.when i return to the outdoor unit i am met with a cloud of freon coming...
  28. Replies
    35
    Views
    3,190

    i never call bat sh.. crazy people back

    i never call bat sh.. crazy people back
  29. Replies
    1
    Views
    344

    Copeland split system pressure stabilizing

    I have noticed on copeland compressors on startup the pressure will drop to as low as 60psi and then take 10-15 min before it gets to operating pressure.Now i did have two LG compressors that did not...
  30. Replies
    1
    Views
    498

    VAC PUMP LOSING OIL

    While using my bullet vac pump yesterday i noticed the oil really low with i filled upon startup.got back to the shop filled up pump put it on a empty 410 bottle and 10 min later the oil level was...
  31. Replies
    43
    Views
    3,705

    I use lennox and rheem and for low budget jobs i...

    I use lennox and rheem and for low budget jobs i use allied product (air-flo or ducane).Are quoting high end jobs by this i mean are these jobes in an area where the homes are worth 300k and up?if so...
  32. Thread: IMPORTED R410

    by splus
    Replies
    3
    Views
    691

    IMPORTED R410

    Was at a supply house that had icool international r410 gas,of course it was alot lower in cost than domestic.Any issues or has anyone even used this yet?
  33. Thread: Ordered new Van

    by splus
    Replies
    15
    Views
    1,851

    2009 e250 extended 180,000 only issue was a...

    2009 e250 extended 180,000 only issue was a leaking steering gear box.
  34. Thread: Ordered new Van

    by splus
    Replies
    15
    Views
    1,851

    i agree about the 3 point turn but the transit...

    i agree about the 3 point turn but the transit does not seem as heavy duty the frame and brakes seem to be the ones used on the f150.Also see there offering a 6 cyl on a 2500 series.
  35. Thread: Ordered new Van

    by splus
    Replies
    15
    Views
    1,851

    any reason you didnt get a super duty cut away?

    any reason you didnt get a super duty cut away?
  36. Replies
    45
    Views
    7,680

    Flushing out line set and coil?

    Leaving a estimate now where another company is changing a r-22 system to r-410 but flushing the line set and coil,system is 10 years old the coil is an adp with a piston which can be changed to the...
  37. Replies
    3
    Views
    758

    its installed horizontal so i was going with...

    its installed horizontal so i was going with making the door bigger if i cant get a coi
  38. Replies
    3
    Views
    758

    19" DEEP A/C COIL

    I need to find a replacement coil for a comfort air air handler the depth with the drain pan is 19".comfort air does not have it as the unit is 11 years old and out of production.Its a 2 ton unit
  39. Replies
    0
    Views
    483

    MILLER M3RL A/C COIL QUESTION

    Did a a/c check on a miller m3rl furnace that had a adp coil in the coil case,it was a downflow model coil.seemed to be working fine but always thought the mobie home coils were different becauce of...
  40. Replies
    0
    Views
    523

    ICOMFOR TWIFI STAT OUTDOOR SENSOR

    Can i use one outdoor sensor and hook it up on two different systems in the same home?The only duty it will have is reading outdoor temp not for humidity control
  41. Replies
    4
    Views
    887

    2 year old install and i did replace my hose...

    2 year old install and i did replace my hose gaskets today,it just seemed like alot of oil
  42. Replies
    4
    Views
    887

    Oil at service valve

    When i removed my guage hose from the suction side of a 410 system some oil came out and it was foamy,system was cooling the superheat was varying 3 degrees under a moderate load its also a orifice...
  43. Replies
    22
    Views
    1,922

    by data plate i mean those were the pressures...

    by data plate i mean those were the pressures listed inside the cover of the condensing unit for charging.80 degree ambient called for 22 sh
  44. Replies
    22
    Views
    1,922

    A/C CHARGING QUESTION

    Did a a/c check today at a 3 year old new home and found a interesting issue.Lennox system with a adp coil piston metering device.Data plate called for 125 psi suction and 325 head pressure,i had 130...
  45. Replies
    7
    Views
    1,164

    C6 nordyne coil 042

    C6 nordyne coil 042
  46. Replies
    7
    Views
    1,164

    mismatched system

    Was doing a pm on a split system at a small diner this week and noticed it was a 4 ton condensing unit with a 3.5 ton coil with a piston r-410.pressures and sh were all with in reason temp drop...
  47. Replies
    10
    Views
    1,515

    ANTI FREEZE TESTING

    Whats a good propylene glycol tester?are the ones used just for this but look like a automotive test unit that accurate
  48. Replies
    17
    Views
    2,323

    I put the guage directly on the pump connection...

    I put the guage directly on the pump connection or should i put it on the end of my vac hose?
  49. Replies
    17
    Views
    2,323

    Thats the pump i saw and the oil was changed and...

    Thats the pump i saw and the oil was changed and the guage is right out of the package
  50. Replies
    17
    Views
    2,323

    Might need a new vac pump

    My yellow jacket 6cfm vac pump will only pull down to 70 microns after an hour with my fieldpiece svg3 guage.should i rebuild it or get a new one?Saw a robinair pump at the supply house but unsure of...
Results 1 to 50 of 611
Page 1 of 13 1 2 3 4