  1. Replies
    37
    Views
    2,285

    Here is a photo of the 2 options

    Here is a photo of the 2 options
  2. Replies
    37
    Views
    2,285

    I think I read the newer compressors have a 1/4Ē...

    I think I read the newer compressors have a 1/4Ē fpt thread on the drain fitting. I came across this brass 1/4Ē mpt thread fitting. It has a stem like a king valve to open/close the 1/4Ē Schroeder...
  3. Replies
    37
    Views
    2,285

    Yea the rotor spins in the center of the stator....

    Yea the rotor spins in the center of the stator. I used rotor for lack of a better term. I was thinking maybe the crank shaft could be slapping the oil. I will monitor it. I will be back to check on...
  4. Replies
    37
    Views
    2,285

    So I have been monitoring this compressor. The...

    So I have been monitoring this compressor. The discharge line temp dropped and hangs about 190 degrees fully loaded. When off though sight glass is at 1/8 of a glass. But when the compressor is...
  5. Replies
    21
    Views
    1,329

    I see you said ď you prefer the MIT417/20Ē but...

    I see you said ď you prefer the MIT417/20Ē but the model you posted was the 410/20. Just wanted to be clear if I was to purchase one. I am also thinking about the fluke 1587
  6. Replies
    21
    Views
    1,329

    Thank you for the book/link. I saved it to my...

    Thank you for the book/link. I saved it to my iBook app.
  7. Replies
    21
    Views
    1,329

    Following up. So when I said the blower and 2...

    Following up. So when I said the blower and 2 condenser fan motors were grounded. They were both reading less that 20 megohms to ground indicated on the supco m500. Anytime the blower energized boom...
  8. Replies
    21
    Views
    1,329

    Multiple ground faults 480v unit

    Checked a Trane TCD210C400EA today. Itís a 480v 3phase unit. I found 2 blown 80a fuses along with the breaker tripped. The blower motor is grounded and the 2 condenser fan motors are grounded. The...
  9. Replies
    20
    Views
    918

    Thanks for posting that tip. Looks like my...

    Thanks for posting that tip. Looks like my assumption was wrong. Iím always open for more knowledge.
  10. Replies
    20
    Views
    918

    Thatís good to know.

    Thatís good to know.
  11. Replies
    20
    Views
    918

    I see the vapor port has a stub pipe. So flipping...

    I see the vapor port has a stub pipe. So flipping the tank will be about the same as leaving it standing upright.
    But in the picture to the right showing just the valve setup. It shows no stub...
  12. Replies
    20
    Views
    918

    I see the vapor port has a stub pipe. So flipping...

    I see the vapor port has a stub pipe. So flipping the tank will be about the same as leaving it standing upright.
  13. Replies
    20
    Views
    918

    I never looked at the inside of the recovery...

    I never looked at the inside of the recovery drum. I assumed the threaded nipple went into the drum a little bit. Kind of like a stand pipe sticking into the drum maybe a inch. As for the filter...
  14. Replies
    20
    Views
    918

    ??? Isnít that the same as hooking up to the...

    ???

    Isnít that the same as hooking up to the liquid port and leaving the tank up right? There is a dip tube going down to the bottom allowing liquid to get pushed out of the tank. Maybe you...
  15. Replies
    20
    Views
    918

    Yea that is true. Itís not so much the price....

    Yea that is true. Itís not so much the price. Mainly it was for a job today and shipping all said Friday is the earliest can arrive. Amazon had a nice looking one for something like $130. I...
  16. Replies
    20
    Views
    918

    I checked out one on Graingerís website. Had good...

    I checked out one on Graingerís website. Had good reviews as far as performing. I was thinking about using a heating blanket that I have laying in the closet. I have to check the temperature rating....
  17. Replies
    37
    Views
    2,285

    I appreciate the input. The 3 plates that I...

    I appreciate the input. The 3 plates that I removed actually were the newer style plates 06ea660137. But the plates given to me by the compressor motor shop were a mix of the older style but...
  18. Replies
    37
    Views
    2,285

    So should I reinstall the 3 plates that are still...

    So should I reinstall the 3 plates that are still good with the same valves? The plates they gave me did not have the hole to hold down the metal gasket. That means the gasket will go back on but...
  19. Replies
    37
    Views
    2,285

    Here are 2 photos of the oil sight glass. The...

    Here are 2 photos of the oil sight glass. The lower one is the front glass near the electrical box. The higher oil glass is towards the back. These levels are while the compressor is running. I did...
  20. Replies
    37
    Views
    2,285

    .

    .
  21. Replies
    37
    Views
    2,285

    Thank you for the reply. I am going back on...

    Thank you for the reply. I am going back on Saturday to reinstall the original valve plates that I removed. These valve plates were the newer style 10-6e-vp. I am going to replace the discharge...
  22. Replies
    37
    Views
    2,285

    I understand the load and unload part. Unload...

    I understand the load and unload part. Unload suction pressure increases. It would be like an undersized compressor compared to the big evap coil. Once the compressor loads itís running 100%. The...
  23. Replies
    37
    Views
    2,285

    Thinking about this further I think itís an issue...

    Thinking about this further I think itís an issue with the compressor. Possibly the wrong gasket or worn piston rings. But I laid out each gasket and made sure it fit properly. Here is the thing I...
  24. Replies
    20
    Views
    918

    Ref. Drum heater blanket

    From time to time I use my recovery machine to returned the recovered gas back into the refrigerant system. The problem is the refrigerant tank becomes ice cold on the outside. The pressure drops in...
  25. Replies
    37
    Views
    2,285

    My suction line leaving each evap coil right at...

    My suction line leaving each evap coil right at the txv sensing bulb for this troubled circuit are the same 47 degrees.
  26. Replies
    37
    Views
    2,285

    Thanks I will send him a message. Here is my...

    Thanks I will send him a message. Here is my latest update Incase he reads it. Looks like the brass nipple is normal. I went by today got a few readings. Security kicked me out. They were not...
  27. Replies
    37
    Views
    2,285

    This is the bottom side of the new unloader. The...

    This is the bottom side of the new unloader. The old unloader removed looked the same. I only replaced 1 other unloader in my past. It did not have this brass nipple inside. It just had a threaded...
  28. Replies
    37
    Views
    2,285

    I will be there Monday morning early to check on...

    I will be there Monday morning early to check on the compressor. I will look into the txv temps. If I get the superheat down. I am sure the discharge temp will drop as well.
  29. Replies
    37
    Views
    2,285

    This unit has 2 compressors and 4 evap circuits. ...

    This unit has 2 compressors and 4 evap circuits. Itís 1 compressor per 2 evap coils. Each evap coil has its own txv. I did not check the superheat leaving each evap. This is a water cooled packaged...
  30. Replies
    37
    Views
    2,285

    The 3 original plates removed were the model #...

    The 3 original plates removed were the model # 10-6e-vp. But the rebuild shop gave me 1 of each model plates shown in the attached photo 1@ 10-6e-vp, 1@ 12-6e-vp, 1@ 13-6e-vp. Would this be a...
  31. Replies
    37
    Views
    2,285

    O6e semi hermetic high discharge temp.

    So this semi recip was running high discharge temps 215 degrees f. Ok customer agreed to replace the valve plates. So planned to valve off compressor but service valves donít hold 100%. Had to...
  32. I found that thread. I was reading the pdfís. I...

    I found that thread. I was reading the pdfís. I still have more reading to do. I was looking for the easy answer lol. Thank you for the info.
  33. Replies
    13
    Views
    1,287

    I appreciate everyoneís input. Itís pretty...

    I appreciate everyoneís input. Itís pretty obvious to differentiate a hgbp vs suction cut off. The main difference is a suction cut off head has the unloader on one side of the head. Then on the...
  34. 06E carlyle dual unloaderproper adjustments

    I have an 06E with 2 unloaders installed. This unit is a water cooled packaged unit DX straight cooling. There are 3 other units like this one. But this is the only compressor with 2 unloaders on one...
  35. Replies
    13
    Views
    1,287

    As for suction type of electric is pretty...

    As for suction type of electric is pretty straight forward. I was trying to differentiate between cut off vs hot gas bypass. If I install a hot gas by pass in a cut off application I will have...
  36. Replies
    13
    Views
    1,287

    I printed a pdf showing the 2 different head...

    I printed a pdf showing the 2 different head design. the heads are different.
  37. Replies
    13
    Views
    1,287

    The guy at my local carrier dealer barely...

    The guy at my local carrier dealer barely understand what I am asking for?over at a-1 compressor the guy was not too helpful. Seemed as if he really did not want to give me to much information. He...
  38. Replies
    13
    Views
    1,287

    Carlyle compressor unloader selection.

    Compressor model number originally 06EA175310.
    The "A" i believe because the compressor originally had a hot gas bypass unloader type. I can see someone stamped a "5" over the "A".The 5 would mean...
  39. Replies
    8
    Views
    581

    I know there is a bunch out there. I am just...

    I know there is a bunch out there. I am just checking everyoneís input on different models you all have used and had good success with. Yes itís a pretty basic device. But the only one I have used...
  40. Replies
    8
    Views
    581

    Freezer temp alarm device??

    Looking for a product that can display the box temperature for a walk in cooler. Also it will ring an audible alarm when the box temp exceeds a set temperature. What do you all use or see in the...
  41. Emerson x line condensing units opinions

    Emerson/Copeland has a condensing unit called the x line. The condenser looks like a minisplit condenser. I am asking about the low temp models. They have all the bells and whistles. Oil separator,...
  42. Replies
    40
    Views
    3,351

    I have to agree with you. The fault should not be...

    I have to agree with you. The fault should not be fully on the cleaning company. It was not right the cleaning guy turned the water off. But it was a mistake. However this is why there is the hi...
  43. Replies
    40
    Views
    3,351

    I called Emerson tech support. Before I could...

    I called Emerson tech support. Before I could not get through. The tech support guy said compressors with the core sense module would be considered an external overload. The ptcr would be the sensor...
  44. Replies
    40
    Views
    3,351

    It is garbage. Later that day I asked the...

    It is garbage. Later that day I asked the maintenance guy what ever happened with the overheated unit? He said ď they turned it back on about 4 hrs later and it tripped the breakerĒ he then said ď...
  45. Replies
    40
    Views
    3,351

    Itís the same model compressor except in another...

    Itís the same model compressor except in another unit. The model number is posted in my first post
  46. Replies
    40
    Views
    3,351

    Yes the core sense module will break the 24v to...

    Yes the core sense module will break the 24v to the contactor coil that part is pretty straight forward. I was wondering if this ptcr substituted for the line voltage overload? With small fractional...
  47. Replies
    40
    Views
    3,351

    I have another question pertaining to this same...

    I have another question pertaining to this same model compressor. On the core sense module there is a high temp sensor (ptcr) if the compressor temp gets too hot the module will open the 24v...
  48. Replies
    40
    Views
    3,351

    For sure it has no dip tube. I opened the sight...

    For sure it has no dip tube. I opened the sight glass and shined a flashlight into the compressor. Then I removed the schraeder valve from the oil access port and looked inside. I can see it just...
  49. Replies
    40
    Views
    3,351

    For sure Iím going with an hh dryer. As far as...

    For sure Iím going with an hh dryer. As far as the room in the system I would probably have to repipe the suction line.
  50. Replies
    40
    Views
    3,351

    I am replacing the compressor. I original failed...

    I am replacing the compressor. I original failed compressor had grounded. I did a quick acid test. The test showed mild. I like to cover my butt. I want to add acid away. But I know there are...