  1. https://event.on24.com/eventRegistration/EventLobb...

    https://event.on24.com/eventRegistration/EventLobbyServlet?target=reg30.jsp&referrer=http%3A%2F%2Finfo.jacksonsystems.com%2Flink.php%3Fa%3D1402%26b%3D64723a3352401a477a10798a16694a8976&eventid=2219087...
  2. Last night I watched a webinar by H-talk member...

    Last night I watched a webinar by H-talk member davidr of National Comfort Institute put on by Jackson Systems. Excellent as always. When they get it put back up so anyone can see it, I'll post a...
  3. Not sure if Rheem gets the VRFs though. Rheem is...

    Not sure if Rheem gets the VRFs though. Rheem is making the full residential line for Fujitsu. So now Fujitsu has furnaces, conventional splits, packs.
  4. Replies
    24
    Views
    481

    The Tempstar is a bare bones builder model....

    The Tempstar is a bare bones builder model. Constant torque air handler. The Amana A/C is more deluxe and better built than the Tempstar also with a constant torque air handler. The Lennox Elite is...
  5. Rheem's minis are made by Fujitsu.

    Rheem's minis are made by Fujitsu.
  6. Replies
    6
    Views
    154

    Success! Good job and thanks, Dave

    Success! Good job and thanks, Dave
  7. Replies
    6
    Views
    154

    Yes on Firefox. Reboot didn't help there.

    Yes on Firefox. Reboot didn't help there.
  8. Replies
    6
    Views
    154

    Can't post from 1 computer on Firefox

    Last couple days on my desktop, I can't post a reply if on with Firefox. Can't click on the quick reply box. I looked for any setting I might have screwed up but couldn't find anything. Tried logging...
  9. Replies
    53
    Views
    1,193

    With Dan's numbers, you need 11,316 BTUs in heat....

    With Dan's numbers, you need 11,316 BTUs in heat. The smallest gas furnace I know of is 26,000 BTU 80% or about 21,000 BTU out. Rather oversized. I don't know of any conventional split at 1 ton heat...
  10. Replies
    6
    Views
    511

    Suburban does make RV stuff but also makes a gas...

    Suburban does make RV stuff but also makes a gas heat PTAC and a unit like a Magic Pak.
    ...
  11. Replies
    1
    Views
    246

    I'd say it varies by coil. For example, our...

    I'd say it varies by coil. For example, our American Standard tech rep told his buyers not to buy a certain A-S/Trane evap as it didn't have the capacity to be a good match with heat pumps. Heating...
  12. Replies
    47
    Views
    1,565

    This coincided with the dead season here so...

    This coincided with the dead season here so making it worse. Have little demand service, a few cleans though had some cancellations. I do some new install inspections. Had this morning's cancel then...
  13. Everyone has their own opinion on equipment. Key...

    Everyone has their own opinion on equipment. Key is best possible installation and correct sizing. My employer has sold Rheem since the 1980s. I've had it in my house, Sis & niece still do. Sis got a...
  14. Replies
    6
    Views
    511

    We have a customer with a Suburban through the...

    We have a customer with a Suburban through the wall unit. Gas heat & electric cool. Couldn't find any parts for it anywhere. Small chassis, still can get a replacement unit for the 16x42 PTAC sized...
  15. There are some that will fit on a 24x24 pad so...

    There are some that will fit on a 24x24 pad so footprint wise, an inch or so smaller each way.

    There are some front discharge units out there now. Can get a little pricey.

    Heat Controller...
  16. Replies
    4
    Views
    475

    That would be a great system if properly sized,...

    That would be a great system if properly sized, installed carefully by industry standards and you have a solid, properly sized duct system. As you can see, so much of it depends upon getting a good...
  17. Thread: Much better

    by BaldLoonie
    Replies
    4
    Views
    408

    Now let's get our members and "customers" back!

    Now let's get our members and "customers" back!
  18. Replies
    10
    Views
    410

    I'm dual fuel with a Prestige IAQ. If Aux or...

    I'm dual fuel with a Prestige IAQ. If Aux or Emerg. heat is called for, the blower is not.
  19. Replies
    7
    Views
    935

    Now I know what the boiler is. Lochinvar. We put...

    Now I know what the boiler is. Lochinvar. We put one in a teeny little rental house. 75K when should have been 50 but smallest boiler we could find plus it has a 2 stage gas valve based on water temp...
  20. Replies
    17
    Views
    917

    It's the breaker in the main panel that trips?...

    It's the breaker in the main panel that trips? May be getting weak and need to be replaced.
  21. It's hard to tell without seeing your duct...

    It's hard to tell without seeing your duct system. Zoning single stage equipment on a duct system not designed for zoning can lead to issues. If you have a duct system designed for the equipment...
  22. Usually the BTUs you gain going larger are all...

    Usually the BTUs you gain going larger are all sensible. So your sensible heat ratio isn't quite as good. You get an extra 1,200 BTUs of cooling in your case but probably sensible. Really doesn't...
  23. My vote is stay with the Infinity.

    My vote is stay with the Infinity.
  24. Replies
    2
    Views
    287

    Most duct systems are undersized for what you...

    Most duct systems are undersized for what you have so if you go bigger you most likely will need to enlarge the duct system, size and or number of supply & return registers. That could make a mess...
  25. Replies
    6
    Views
    539

    You took out a Thermopride and put in a Payne....

    You took out a Thermopride and put in a Payne. GASP. :D But anyway, great job. Turning vanes a nice touch.
  26. Haven't seen a plugged secondary trip the main...

    Haven't seen a plugged secondary trip the main limit, but typically trip the rollout.
  27. The BK terminal has nothing to do with the...

    The BK terminal has nothing to do with the Aprilaire automatic humidifier. It's for slowing the blower to do DEhumidify on demand with a control that support that feature.
  28. We don't sell Carrier brands so don't know how...

    We don't sell Carrier brands so don't know how they are holding up. Just a little nervous. I would guess they are holding up or Carrier would have yanked them but you never know.
  29. Locally we have 3 Johnstones and less than a mile...

    Locally we have 3 Johnstones and less than a mile from one of them is Lute Supply, I think it is an Ohio chain, that sells it too. We also have Goodman's own distribution but Johnstone warehouses it...
  30. Replies
    11
    Views
    370

    1-800-GE-CARES

    1-800-GE-CARES
  31. The 5 stage is a rotary compressor, the variable...

    The 5 stage is a rotary compressor, the variable speed is a Copeland scroll on a Carrier. Personally I'd trust the scroll over the rotary for reliability. I'm old, I remember when Fedders tried a...
  32. If you can find a H-Talk company that services...

    If you can find a H-Talk company that services your area, jump on it. I ran a service call on an internet purchased system. Leaking indoor coil. He would need a contractor to remove the coil, he...
  33. That basement has to be going negative and...

    That basement has to be going negative and pulling flue gases out of the WH draft hoods.
  34. Once you get down to lower 20s, most heat pumps...

    Once you get down to lower 20s, most heat pumps will run much of the time as cool as you keep it. Keep it 70 and it would be non stop with backup coming on occasionally.

    In the teens may well be...
  35. Replies
    5
    Views
    317

    Charging chart agrees with you. 30 out, 70 in you...

    Charging chart agrees with you. 30 out, 70 in you should be running about 280 head not 400. 50 subcool says so too.

    4 blinks is hard lockout, happens after 9 LPCO openings. Now this is a manual...
  36. Thread: Rheem coils

    by BaldLoonie
    Replies
    6
    Views
    414

    It's usually lots of pinhole leaks. Not sure...

    It's usually lots of pinhole leaks. Not sure about repairing them. Then more would pop up. I've heard of class action suits with a couple of brands but not Rheem. Sure did cost us. Owner of heating...
  37. We probably would cover it or at least work with...

    We probably would cover it or at least work with you on the cost. Techs SHOULD check schraeders for leaks after taking their hoses off but many don't.
  38. Bosch sells (doesn't make) an inverter heat pump....

    Bosch sells (doesn't make) an inverter heat pump. It has an air handler like any. Uses a standard thermostat and logic to determine how hard to work. Seems like it heats down to -4 but can have...
  39. Cold weather minis, Mitsu's Hyper Heat, with some...

    Cold weather minis, Mitsu's Hyper Heat, with some baseboard electric or hot water in case of HP failure. Hard to humidify but if build the place tight you won't need to. A ducted system with a big...
  40. Replies
    5
    Views
    234

    Usually the main zone has to have separate B & O...

    Usually the main zone has to have separate B & O terminals to tell the panel if the system should be in heat or cool mode. Then as you said, the other stats had 3 wires and often didn't have a...
  41. Replies
    9
    Views
    464

    Instead of uninsulated metal pipe or uninsulated...

    Instead of uninsulated metal pipe or uninsulated flexible tubing, get a good R8 flex duct. I don't think you'll have condensation. Of course a cheapo fan may not be able to overcome 35' so an inline...
  42. Yea, I forgot there's some rocket scientists out...

    Yea, I forgot there's some rocket scientists out there that couldn't figure out low voltage wiring if they had to :(
    Like the one who wired this up upon installation.
  43. What's the inducer? ECM with the square motor or...

    What's the inducer? ECM with the square motor or 3 phase with the round motor? Probably the former unless it has been upgraded. That's a symptom of an inducer problem and you have to get a kit to...
  44. Stat says works on heat pump without backup so my...

    Stat says works on heat pump without backup so my guess is someone wired it for straight electric. My bet is needs the right stat. Won't take long for a tech to figure that one out.
  45. Only thing I'd disagree with your fine...

    Only thing I'd disagree with your fine explanation of the technologies is # of speeds in a constant torque motor. The X13 is 5 speed. But other models and brands have more. AS/Trane use the Genteq...
  46. The downflow variable speed blower model has no...

    The downflow variable speed blower model has no Y1 and Y2* but does have dehumidify on demand. Creative low voltage wiring could have that for Y1 to slow the blower and Y for high stage to get full...
  47. Replies
    33
    Views
    984

    A service call from a pro is peanuts compared to...

    A service call from a pro is peanuts compared to what you are spending on the house.
  48. Replies
    14
    Views
    596

    Guess I better specify, heat pump stat with...

    Guess I better specify, heat pump stat with backup capability. This neck of the woods, that's a must!
  49. Replies
    14
    Views
    596

    Lotta low end stats aren't designed for a pump....

    Lotta low end stats aren't designed for a pump. Got one on my desk, Emerson 1F86-0244, our basic non programmable. Probably would be wise to switch to a HP model but that adds bucks.
  50. Replies
    11
    Views
    352

    Payne is bare bones Carrier, A/C made in Mexico....

    Payne is bare bones Carrier, A/C made in Mexico. Usually sold to anyone with green in their hand.

    What models York?

    What models Carrier? 2 stage A/Cs are pricey, surprised only 10% over York.