Buy a detec or h-10. Only two I’ve found reliable or accurate enough
Type: Posts; User: ehsx
Buy a detec or h-10. Only two I’ve found reliable or accurate enough
[QUOTE=VTP99;25988228]What's the difference between operating & shipping ?[/QUOTe
Shipping includes crating, operating include water in tower.
No excuse with new equipment. Had an old bac, rust & scale probably as heavy as the tower. Crane tilted and tower sides collapsed, but no other damages other than underwear.
TABLE 403.3.1.1
MINIMUM VENTILATION RATES
J. If the tenants of the dwelling have exclusive use of the garage below, no exhaust is required.
100 cfm per car if multiple tenants
What's wrong with a mixing tank?
You need to look at the controls sequence.
?????
using 44* water to make 42*f water?
Wolverine used to have cross reference numbers for old York chiller tubes, they went bankrupt and recently reopened but not doing chiller tubes .
Typically need equipment order specs since a...
Good if heat exchangers have glycol or are drained. Butterfly and check valves should not be trusted. Larger valves have more leak potential. Always evaluate worst case potentials. Saving a few...
Thats what i call a survivalist!
sent
So long as you have isolation valves that hold. Always skeptical about leaving unattended charge in condenser or evap. Seen a few chillers freeze up if water left in heat exchangers.
There are three manuals, 050, 063/087, 100/126.
Which is needed?
Evaporator approach?
Would love to see the piping drawing for that system. Most of issues that I’ve seen required adjusting the charge as seasons changed.
If you have a receiver you must maintain a liquid seal to the expansion valve be either using elevation, pressurized control, or suction/liquid line heat exchangers. Seen a number of r22 systems...
Lots of free power points online.
Danfoss , emerson/copeland has a couple of dozen shorts ,some with quiz's.
email me and I’ll send a few Items next week.
Under all loads there must be adequate subcooling at the expansion valve to feed without flashing before the valve seat, ~2-4*f sc. subcooling drops as you unload, line and components cause sc loss,...
Stranded and twisted groups give better flexibility , what has not been addressed is how twisted groups reduce induction.
Mfg’s have changed to twisted or shielded, added movs or other...
Guess you have never seen a mollier diagram. Or does science not apply in your world?
I’m done with your non- sense.
General info, listed water cooled & air cooled
Trane is the only company that I’m aware of that balances a wheel on the compressor. The term would indicate a different procedure in most cases. I had asked earlier that you clarify the procedure,...
York used to test run closed systems with “dry” air. Combination of pressure and temp caused combustion of oil and chiller exploded killing the testers. That was when ashrae changed the policy on...
See ashrae 15- 1994. Air shall not be used for pressure testing or run test.
Air run implies running a machine using air. Used to be a common test procedure on older equipment. Running a...
List the complete procedure for discharge gas for air run. Can’t recirculate was what i was referring to. Hot air from compressor air run blew up at York and same has happened at allis chambers.
Run with air and risk combustion.
Probably been working on centrifugal before you was born.
Clarify “air run”. Air run is illegal since 90’s accident at York that killed a few. Nitrogen ok.
Ceramic or oil filled. Nothing with red hot elements or anything hot enough to catch a paper towel on fire.
Best to start with 80-90% of name plate and trim based on full log sheet and design data. Mfg literature or as sold design info as reference.
Assuming full load design conditions, charge by subcooling. Verify ssh, dsh sh, evap approach, liquid line approach, & condenser approach.
Subcooling will drop as load decreases.
Ssh with txv...
Use gum wrappers for < 2 amps...
That's better than the "Darwin Award winner" who used a 22 rimfire in a truck fuse holder, shot his self in his pride, ran into a canal and drowned....
Tech told me once he knew how may strands...
Just a fyi. Electronic air cleaners can create ozone & odors when connected directly to a tight 90 due to extreme flow variations.
Air flow needs to be fairly even across the elements. Couldn't...
Yea, but they are made in China and doesn’t affect global warming!
New or existing older job?
How much of the condenser water piping is higher than the tower basin? Type tower, model? Iso?
Smacna has good manuals
Line reactor is listed as an accessory. Do you have it?
Line reactor:
Increased reliability and life span of the VFD
Provide some protection against over-voltage trips
A cost-effective...
Being near so many oil and chemical refineries check with some of the construction and maintenance companies also. They typically will have hvac service techs plus call in outside help where you may...
Never heard of aluminum out gassing? Heat pump? Model?
I had a new rooftop Carrier installation that smelled like sewer gas. Third trip there I found the roofers broken the sewer vent pipe low...
Chill water: Once you get into design build, motors maybe oversized as much as 50% to get best full load efficiency, closer to nominal gives better part load.
To get hp/fla you have to request...
Some techs like the digital gauges because some give a digital log. I don't like the printout because 30-50% of the info needed for through analysis on a log sheet is missing.
No expendables, no...
Don passed away last week due to Covid. He was 75 years old, retired about 4 years ago from chiller training position at Daikin, Staunton VA. He started with Westinghouse after leaving the Navy,...
"Any opinions about this "BAD ASS HVAC" video?"
.
Not upsetting me, just showing your lack of professionalism. If this is your way of having fun I feel sorry for your customers and "guild" members.
"Guys, my Tesla went up $250k on Friday alone. A year ago that amount of money was mind boggling to me. My year has been insane not just in bad ways.
So no, IDGAF about making any wrinkles, or...
R134a pressures much higher, check asme vessel ratings.
I just see it as commitment. Parables can mean different things ... all I’ve expected is honesty, leave if you like.
These discussions remind me of the vineyard workers parable, Matthew 20:1-16
Don’t expect more than originally agreed, Do what you agreed and are paid to do. Change jobs if not satisfied,...
If Centrifugal retro may require new gears & impeller, gaskets, o-rings, if hermetic maybe motor. Code requires permit& new nameplate if over x lbs ref. Eddy test tubes......
Probably more...
I don’t watch videos over 15 minutes unless involves attractive women, paid to watch, or have a need to watch.
Any time you don’t make an impact in the first couple of minutes you’ve lost most...
Just ordered a few EXV, coils on backlog, made in India. Anyone else having valve supply issues?