    1,061

    Me too;) OK, I got that. In my...

    Me too;)



    OK, I got that.



    In my experience it's possible to have an evaporator superheat which is greater than the evaporator TD...ie, if you have a 35F box and 25F evaporator...
  4. Replies
    24
    Views
    1,061

    Hey, sorry. I read it and thought I had replied....

    Hey, sorry. I read it and thought I had replied. It's possible I forgot to hit Submit. That kind of f-up happens more often than I'd like these days. ;)

    Climacheck isn't something I was aware...
  5. Replies
    24
    Views
    1,061

    Sorry, but in my experience I have only used...

    Sorry, but in my experience I have only used Sporlan or Also (Emerson) expansion valves and neither of them use evaporator superheat as a parameter in valve selection. So when you ask about how...
  6. Replies
    5
    Views
    489

    While I agree only an OEM trap will fit, but I've...

    While I agree only an OEM trap will fit, but I've seen cases where the drain was reduced to 1" to accomodate a running trap.
  7. Replies
    24
    Views
    1,061

    Bob, you're mixing up you're terms and making a...

    Bob, you're mixing up you're terms and making a simple selection procedure much more difficult,

    The static superheat value has no relationship to the valve's rated capacity, so disregard it when...
  8. It's basically the same material as the pipe...

    It's basically the same material as the pipe insulation but it's in sheet form. Here's a link: https://www.armacell.us/products/aparmaflexaparmaflexfs/
  9. I haven't read his book, but I've watched most of...

    I haven't read his book, but I've watched most of his YouTube videos. He explains how we're being scammed through our health insurance and how their Medicare advantage and Supplement plans simply...
  10. Replies
    9
    Views
    575

    I started a thread some time ago about how to...

    I started a thread some time ago about how to diagnose a cap tube system with what I call the Touchy Feely method, using only your sense of touch...ie, no tools.
    ...
  11. Replies
    17
    Views
    813

    You can use the Tecumseh Cap tube app that I used...

    You can use the Tecumseh Cap tube app that I used and select .042", which is the closest size J.B has.
    Or you can use J.B.'s resizing chart to find the equivalent length of .042" cap tube:
    ...
  12. Replies
    17
    Views
    813

    The standard box temperature for an ice...

    The standard box temperature for an ice merchandiser is 20F. I usually use a +10F evaporator temperature for these cap tube selections.

    The performance data sheet for a Tecumseh AEA4440 goes...
  13. Thread: one drive??

    by icemeister
    Replies
    3
    Views
    860

    For a How-To guide to get rid of the OneDrive...

    For a How-To guide to get rid of the OneDrive popups go here: https://www.howtogeek.com/342550/get-rid-of-the-annoying-microsoft-onedrive-sign-in-popup/
  14. Replies
    13
    Views
    675

    The 04 orifice looks good for a quick selection,...

    The 04 orifice looks good for a quick selection, but before finalizing your job planning it's always a good idea to do a longhand selection using the manufacturer's selection procedure. I've done a...
  15. Replies
    13
    Views
    675

    E&E, the QR3-112 will work fine. I agree at 2C...

    E&E, the QR3-112 will work fine. I agree at 2C (35F) box temperature it will run a higher TD of about 8.2C (15F) as well as a higher capacity of about 7750 w. A TD of 8.2C (15F) is quite...
  16. Replies
    17
    Views
    990

    Left-Handed Twist Ties

    Why is it in this right-hand dominant, righty-tighty / lefty-loosey world do I find so many twist ties that have been twisted on counter-clockwise?
    Is it because bakeries somehow attract lefties?
  17. Replies
    13
    Views
    675

    Wow, I really messed up in my numbers above. ...

    Wow, I really messed up in my numbers above. :eek:
    I think I tripped interpreting my scribbled calculations likely due to my Metric disabilities.
    The last paragraph should read:

    The medium...
  18. Replies
    13
    Views
    675

    I can see that the original compressor and...

    I can see that the original compressor and evaporator would be a decent match at an evaporator temperature of approximately -23C (-10F). This was assuming the evaporator capacity of 5600 watts ...
  19. Replies
    57
    Views
    1,799

    Dad summed up the history of HVAC-Talk and Snuffy...

    Dad summed up the history of HVAC-Talk and Snuffy here:
    https://hvac-talk.com/vbb/showthread.php?2214301-Sold-again-Welcome-to-Endeavor-Business-Media-!!
  20. One great thing about Packless is they will help...

    One great thing about Packless is they will help you with the proper selection of heat exchanger. So if you need a minimum of 20F superheat at the compressor, they can size it for you.

    They say...
  21. To have 3F superheat at the evaporator outlet...

    To have 3F superheat at the evaporator outlet and 0F superheat after the accumulator makes no sense, unless the accumulator is metering back some liquid from a recent liquid slug.

    What is the...
  22. Replies
    19
    Views
    681

    I've seen combo cooler/freezer walk-ins where the...

    I've seen combo cooler/freezer walk-ins where the cooler had no floor and had 4" high floor screed sections to make up the difference.

    As crazzycajun suggested, contact the manufacturer and ask...
  23. Here's a good read from Fluke on HVAC motors...

    Here's a good read from Fluke on HVAC motors Insulation Resistance Testing (IRT):

    https://www.fluke.com/en/learn/blog/hvac/insulation-resistance-and-electrical-testing-for-hvac-compressor-motors
  24. I don't recall posting that video, but I do have...

    I don't recall posting that video, but I do have that publication by Megger:

    819495
  25. The refrigerant is a blend which probably...

    The refrigerant is a blend which probably contains R404A and several other components. Such refrigerants are typically proprietary so it is only available from its manufacturer.

    I suggest you...
  26. The nominal pressure drop for an expansion valve...

    The nominal pressure drop for an expansion valve isn't fixed at 100 psi. For R404A at 40F evaporator temperature it's 100 psi, but at 20F it's 125 psi and at -20F it's 150 psi. The temperature of...
  27. Replies
    54
    Views
    1,338

    Scroll down the page to the capacity chart. I...

    Scroll down the page to the capacity chart. I selected -20F SST at 95F ambient. I notice now I got the NDB50 capacity wrong. I was in the wrong column. Oops!
    It should have been 217,094/2 or...
  28. Replies
    54
    Views
    1,338

    It's impossible to put numbers on something like...

    It's impossible to put numbers on something like this. That 5% number is just a typical oil circulation rate that I've seen used quite often when describing a pumper. Also higher compression ratios...
  29. Replies
    54
    Views
    1,338

    The unit in your pic shows a single wide NSB...

    The unit in your pic shows a single wide NSB model. The 50 hp unit is a double wide NDB, so there's plenty of room for two compressors.

    819375819376
  30. Replies
    54
    Views
    1,338

    This isn't referring to the oil pump, but rather...

    This isn't referring to the oil pump, but rather it's about the amount of oil leaving the compressor due to worn rings, pistons and/or cylinders. The normal amount of oil leaving is about 1% whereas...
  31. Replies
    54
    Views
    1,338

    That's a good point. I mentioned stranding of...

    That's a good point. I mentioned stranding of oil in the receiver with mixtures of mineral oil and POE, but I've read that stranding can happen with systems with very high oil circulation. The oil...
  32. Replies
    54
    Views
    1,338

    One circuit of a 40 hp condensing unit at -20F/...

    One circuit of a 40 hp condensing unit at -20F/ 95F ambient will do 81,510 Btuh. The 2 5/8"" suction line velocity would be 1481 FPM and the pressure drop over 100 ft would be 0.3 psi.

    One...
  33. Replies
    54
    Views
    1,338

    https://century-refrigeration.com/wp-content/uploa...

    https://century-refrigeration.com/wp-content/uploads/2017/05/NSB-404-507.pdf
  34. Replies
    54
    Views
    1,338

    Discharge on a condensing unit is factory piping...

    Discharge on a condensing unit is factory piping within the unit, not liquid and suction which are field piping.
  35. Replies
    54
    Views
    1,338

    I read that to mean liquid line and suction...

    I read that to mean liquid line and suction line.... 1 1/8" / 2 5/8"
  36. Replies
    54
    Views
    1,338

    Is there a possibility of this circuit's oil...

    Is there a possibility of this circuit's oil having a mix of mineral oil and as well as POE, such as if someone inadvertently added mineral oil instead of POE sometime during all of these service...
  37. Replies
    54
    Views
    1,338

    What you describe is not oil migration, it sounds...

    What you describe is not oil migration, it sounds to me to be oil loss...most likely from the multiple header failures. (I assume these were discharge header cracks.)

    What type of compressors and...
  38. Replies
    11
    Views
    674

    Most likely, if there is such a tool as you...

    Most likely, if there is such a tool as you describe, it's only made by Emerson and not available for resale.

    I've never had a need for one and if I had, the timely and least costly solution for...
  39. Replies
    7
    Views
    619

    I've done it on ocaission while waiting for the...

    I've done it on ocaission while waiting for the OEM temperature control and had no issues.

    The one thing I can say about it though, is as the box temperature drops, the compressor's going to see...
  40. Replies
    19
    Views
    1,826

    I agree we fridgies tend not to pay much...

    I agree we fridgies tend not to pay much attention to subcooling, but there are times when it can be a valuable troubleshooting tool...and this is one of them.

    I see this thread as an example of...
  41. Replies
    5
    Views
    1,444

    Basically the effect of the mechanical subcooling...

    Basically the effect of the mechanical subcooling supplied to the case would have little to no difference in the required conditions at the case. The added subcooling is used for system capacity...
  42. Replies
    9
    Views
    733

    Tyler Refrigeration specified suction stop...

    Tyler Refrigeration specified suction stop solenoids for some of their cases with conventional or single compressors. They didn't result in floodback or slugging.

    If you think about it, during...
  43. Based on 3000 Btuh at -10F SST and 120F SCT...

    Based on 3000 Btuh at -10F SST and 120F SCT with R404A, a .052" ID x 95" cap tube with 36" of heat exchange length will work well.


    818884
  44. Replies
    72
    Views
    3,347

    You're correct to have heat exchange between the...

    You're correct to have heat exchange between the cap tube and suction line for the added subcooling, but for the wrong reasoning.

    The subcooling gained from this heat exchange doesn't increase the...
  45. Replies
    40
    Views
    3,200

    When there's a possibility of hydrostatic failure...

    When there's a possibility of hydrostatic failure of liquid line piping or component, it's common to install a differential pressure type relief valve. If there's a solenoid valve downstream of a...
  46. In the 50's and 60's my father kept a dozen or so...

    In the 50's and 60's my father kept a dozen or so spare motors on the shelf at the shop. They were 1/4 hp up to maybe 3 hp.
    Whenever a customer's motor died they were installed as "loaners" while...
  47. Replies
    15
    Views
    664

    What is the Tecumseh condensing unit's model...

    What is the Tecumseh condensing unit's model number?

    Go to Tecumseh Boxload page, select Condensing Unit Data Sheets and scroll down the dropdown menu to find the model. It'll give you what the...
  48. What is the model number of the existing...

    What is the model number of the existing compressor?
  49. Replies
    8
    Views
    630

    If you think in terms of temperature instead of...

    If you think in terms of temperature instead of pressure, then it's much easier to estimate what the conditions should be regardless of what refrigerant you have.

    So the question should be: What...
  50. Thread: Suspicious

    by icemeister
    Replies
    16
    Views
    884

    Your link worked, but this one is more direct: ...

    Your link worked, but this one is more direct: https://icemeister.net/backroom/wp-content/uploads/2015/04/AndySchoen_A-Modern-Method-of-Properly-Sizing-Capillary-Tubes.pdf